Cargando…
Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays
Background and purpose — Severe backside wear, observed in older generations of total knee replacements (TKRs), led to redesign of locking mechanisms to reduce micromotions between tibial tray and inlay. Since little is known about whether this effectively reduces backside wear in modern designs, we...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5251266/ https://www.ncbi.nlm.nih.gov/pubmed/27781667 http://dx.doi.org/10.1080/17453674.2016.1248202 |
_version_ | 1782497781714255872 |
---|---|
author | Łapaj, Łukasz Mróz, Adrian Kokoszka, Paweł Markuszewski, Jacek Wendland, Justyna Helak-Łapaj, Celina Kruczyński, Jacek |
author_facet | Łapaj, Łukasz Mróz, Adrian Kokoszka, Paweł Markuszewski, Jacek Wendland, Justyna Helak-Łapaj, Celina Kruczyński, Jacek |
author_sort | Łapaj, Łukasz |
collection | PubMed |
description | Background and purpose — Severe backside wear, observed in older generations of total knee replacements (TKRs), led to redesign of locking mechanisms to reduce micromotions between tibial tray and inlay. Since little is known about whether this effectively reduces backside wear in modern designs, we examined backside damage in retrievals of various contemporary fixed-bearing TKRs. Patients and methods — A consecutive series of 102 inlays with a peripheral (Stryker Triathlon, Stryker Scorpio, DePuy PFC Sigma, Aesculap Search Evolution) or dovetail locking mechanism (Zimmer NexGen, Smith and Nephew Genesis II) was examined. Articular and backside surface damage was evaluated using the semiquantitative Hood scale. Inlays were examined using scanning electron microscopy (SEM) to determine backside wear mechanisms. Results — Mean Hood scores for articular (A) and backside (B) surfaces were similar in most implants—Triathlon (A: 46, B: 22), Genesis II (A: 55, B: 24), Scorpio (A: 57, B: 24), PFC (A: 52, B: 20); Search (A: 56, B: 24)—except the NexGen knee (A: 57, B: 60), which had statistically significantly higher backside wear scores. SEM studies showed backside damage caused by abrasion related to micromotion in designs with dovetail locking mechanisms, especially in the unpolished NexGen trays. In implants with peripheral liner locking mechanism, there were no signs of micromotion or abrasion. Instead, “tray transfer” of polyethylene and flattening of machining was observed. Interpretation — Although this retrieval study may not represent well-functioning TKRs, we found that a smooth surface finish and a peripheral locking mechanism reduce backside wear in vivo, but further studies are required to determine whether this actually leads to reduced osteolysis and lower failure rates. |
format | Online Article Text |
id | pubmed-5251266 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-52512662017-02-04 Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays Łapaj, Łukasz Mróz, Adrian Kokoszka, Paweł Markuszewski, Jacek Wendland, Justyna Helak-Łapaj, Celina Kruczyński, Jacek Acta Orthop Knee Background and purpose — Severe backside wear, observed in older generations of total knee replacements (TKRs), led to redesign of locking mechanisms to reduce micromotions between tibial tray and inlay. Since little is known about whether this effectively reduces backside wear in modern designs, we examined backside damage in retrievals of various contemporary fixed-bearing TKRs. Patients and methods — A consecutive series of 102 inlays with a peripheral (Stryker Triathlon, Stryker Scorpio, DePuy PFC Sigma, Aesculap Search Evolution) or dovetail locking mechanism (Zimmer NexGen, Smith and Nephew Genesis II) was examined. Articular and backside surface damage was evaluated using the semiquantitative Hood scale. Inlays were examined using scanning electron microscopy (SEM) to determine backside wear mechanisms. Results — Mean Hood scores for articular (A) and backside (B) surfaces were similar in most implants—Triathlon (A: 46, B: 22), Genesis II (A: 55, B: 24), Scorpio (A: 57, B: 24), PFC (A: 52, B: 20); Search (A: 56, B: 24)—except the NexGen knee (A: 57, B: 60), which had statistically significantly higher backside wear scores. SEM studies showed backside damage caused by abrasion related to micromotion in designs with dovetail locking mechanisms, especially in the unpolished NexGen trays. In implants with peripheral liner locking mechanism, there were no signs of micromotion or abrasion. Instead, “tray transfer” of polyethylene and flattening of machining was observed. Interpretation — Although this retrieval study may not represent well-functioning TKRs, we found that a smooth surface finish and a peripheral locking mechanism reduce backside wear in vivo, but further studies are required to determine whether this actually leads to reduced osteolysis and lower failure rates. Taylor & Francis 2017-02 2016-10-20 /pmc/articles/PMC5251266/ /pubmed/27781667 http://dx.doi.org/10.1080/17453674.2016.1248202 Text en © 2016 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0) |
spellingShingle | Knee Łapaj, Łukasz Mróz, Adrian Kokoszka, Paweł Markuszewski, Jacek Wendland, Justyna Helak-Łapaj, Celina Kruczyński, Jacek Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays |
title | Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays |
title_full | Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays |
title_fullStr | Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays |
title_full_unstemmed | Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays |
title_short | Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: A retrieval analysis of 102 inlays |
title_sort | peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty: a retrieval analysis of 102 inlays |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5251266/ https://www.ncbi.nlm.nih.gov/pubmed/27781667 http://dx.doi.org/10.1080/17453674.2016.1248202 |
work_keys_str_mv | AT łapajłukasz peripheralsnapfitlockingmechanismsandsmoothsurfacefinishoftibialtraysreducebacksidewearinfixedbearingtotalkneearthroplastyaretrievalanalysisof102inlays AT mrozadrian peripheralsnapfitlockingmechanismsandsmoothsurfacefinishoftibialtraysreducebacksidewearinfixedbearingtotalkneearthroplastyaretrievalanalysisof102inlays AT kokoszkapaweł peripheralsnapfitlockingmechanismsandsmoothsurfacefinishoftibialtraysreducebacksidewearinfixedbearingtotalkneearthroplastyaretrievalanalysisof102inlays AT markuszewskijacek peripheralsnapfitlockingmechanismsandsmoothsurfacefinishoftibialtraysreducebacksidewearinfixedbearingtotalkneearthroplastyaretrievalanalysisof102inlays AT wendlandjustyna peripheralsnapfitlockingmechanismsandsmoothsurfacefinishoftibialtraysreducebacksidewearinfixedbearingtotalkneearthroplastyaretrievalanalysisof102inlays AT helakłapajcelina peripheralsnapfitlockingmechanismsandsmoothsurfacefinishoftibialtraysreducebacksidewearinfixedbearingtotalkneearthroplastyaretrievalanalysisof102inlays AT kruczynskijacek peripheralsnapfitlockingmechanismsandsmoothsurfacefinishoftibialtraysreducebacksidewearinfixedbearingtotalkneearthroplastyaretrievalanalysisof102inlays |