Cargando…

Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device

Many clinicians caring for patients with continuous flow left ventricular assist devices (CF-LVAD) use ramp right heart catheterization (RHC) studies to optimize pump speed and also to troubleshoot CF-LVAD malfunction. An investigational device, the ReliantHeart Heart Assist 5 (Houston, TX), provide...

Descripción completa

Detalles Bibliográficos
Autores principales: Banerjee, Dipanjan, Dutt, Debleena, Duclos, Sebastien, Sallam, Karim, Wheeler, Matthew, Ha, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5253195/
https://www.ncbi.nlm.nih.gov/pubmed/28163837
http://dx.doi.org/10.4330/wjc.v9.i1.55
_version_ 1782498133056421888
author Banerjee, Dipanjan
Dutt, Debleena
Duclos, Sebastien
Sallam, Karim
Wheeler, Matthew
Ha, Richard
author_facet Banerjee, Dipanjan
Dutt, Debleena
Duclos, Sebastien
Sallam, Karim
Wheeler, Matthew
Ha, Richard
author_sort Banerjee, Dipanjan
collection PubMed
description Many clinicians caring for patients with continuous flow left ventricular assist devices (CF-LVAD) use ramp right heart catheterization (RHC) studies to optimize pump speed and also to troubleshoot CF-LVAD malfunction. An investigational device, the ReliantHeart Heart Assist 5 (Houston, TX), provides the added benefit of an ultrasonic flow probe on the outflow graft that directly measures flow through the CF-LVAD. We performed a simultaneous ramp RHC and echocardiogram on a patient who received the above CF-LVAD to optimize pump parameters and investigate elevated flow through the CF-LVAD as measured by the flow probe. We found that the patient’s hemodynamics were optimized at their baseline pump speed, and that the measured cardiac output via the Fick principle was lower than that measured by the flow probe. Right heart catheterization may be useful to investigate discrepancies between flow measured by a CF-LVAD and a patient’s clinical presentation, particularly in investigational devices where little clinical experience exists. More data is needed to elucidate the correlation between the flow measured by an ultrasonic probe and cardiac output as measured by RHC.
format Online
Article
Text
id pubmed-5253195
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-52531952017-02-04 Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device Banerjee, Dipanjan Dutt, Debleena Duclos, Sebastien Sallam, Karim Wheeler, Matthew Ha, Richard World J Cardiol Case Report Many clinicians caring for patients with continuous flow left ventricular assist devices (CF-LVAD) use ramp right heart catheterization (RHC) studies to optimize pump speed and also to troubleshoot CF-LVAD malfunction. An investigational device, the ReliantHeart Heart Assist 5 (Houston, TX), provides the added benefit of an ultrasonic flow probe on the outflow graft that directly measures flow through the CF-LVAD. We performed a simultaneous ramp RHC and echocardiogram on a patient who received the above CF-LVAD to optimize pump parameters and investigate elevated flow through the CF-LVAD as measured by the flow probe. We found that the patient’s hemodynamics were optimized at their baseline pump speed, and that the measured cardiac output via the Fick principle was lower than that measured by the flow probe. Right heart catheterization may be useful to investigate discrepancies between flow measured by a CF-LVAD and a patient’s clinical presentation, particularly in investigational devices where little clinical experience exists. More data is needed to elucidate the correlation between the flow measured by an ultrasonic probe and cardiac output as measured by RHC. Baishideng Publishing Group Inc 2017-01-26 2017-01-26 /pmc/articles/PMC5253195/ /pubmed/28163837 http://dx.doi.org/10.4330/wjc.v9.i1.55 Text en ©The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Case Report
Banerjee, Dipanjan
Dutt, Debleena
Duclos, Sebastien
Sallam, Karim
Wheeler, Matthew
Ha, Richard
Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
title Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
title_full Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
title_fullStr Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
title_full_unstemmed Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
title_short Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
title_sort simultaneous ramp right heart catheterization and echocardiography in a reliantheart left ventricular assist device
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5253195/
https://www.ncbi.nlm.nih.gov/pubmed/28163837
http://dx.doi.org/10.4330/wjc.v9.i1.55
work_keys_str_mv AT banerjeedipanjan simultaneousramprightheartcatheterizationandechocardiographyinareliantheartleftventricularassistdevice
AT duttdebleena simultaneousramprightheartcatheterizationandechocardiographyinareliantheartleftventricularassistdevice
AT duclossebastien simultaneousramprightheartcatheterizationandechocardiographyinareliantheartleftventricularassistdevice
AT sallamkarim simultaneousramprightheartcatheterizationandechocardiographyinareliantheartleftventricularassistdevice
AT wheelermatthew simultaneousramprightheartcatheterizationandechocardiographyinareliantheartleftventricularassistdevice
AT harichard simultaneousramprightheartcatheterizationandechocardiographyinareliantheartleftventricularassistdevice