Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure

The increased prevalence of obstructive sleep apnea (OSA) in congestive heart failure (CHF) may be associated with rostral fluid shift. We investigated the effect of overnight rostral fluid shift on pharyngeal collapsibility (Pcrit), pharyngeal caliber (APmean), and apnea‐hypopnea index (AHI) in CHF...

Descripción completa

Detalles Bibliográficos
Autores principales: Carlisle, Tom, Ward, Neil R., Atalla, Angela, Cowie, Martin R., Simonds, Anita K., Morrell, Mary J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5256151/
https://www.ncbi.nlm.nih.gov/pubmed/28057850
http://dx.doi.org/10.14814/phy2.12956
_version_ 1782498656871514112
author Carlisle, Tom
Ward, Neil R.
Atalla, Angela
Cowie, Martin R.
Simonds, Anita K.
Morrell, Mary J.
author_facet Carlisle, Tom
Ward, Neil R.
Atalla, Angela
Cowie, Martin R.
Simonds, Anita K.
Morrell, Mary J.
author_sort Carlisle, Tom
collection PubMed
description The increased prevalence of obstructive sleep apnea (OSA) in congestive heart failure (CHF) may be associated with rostral fluid shift. We investigated the effect of overnight rostral fluid shift on pharyngeal collapsibility (Pcrit), pharyngeal caliber (APmean), and apnea‐hypopnea index (AHI) in CHF patients. Twenty‐three optimally treated systolic CHF patients were studied. Neck circumference was measured immediately prior to sleep in the evening and immediately after waking in the morning as a marker of rostral fluid shift. Pcrit was measured during sleep, early and late in the night. APmean was measured using acoustic reflection at the same times as neck circumference measurements. 15/23 CHF patients experienced an overnight increase in neck circumference; overall neck circumference significantly increased overnight (mean±SD, evening: 41.7 ± 3.2 cm; morning: 42.3 ± 3.1 cm; P = 0.03). Pcrit increased significantly overnight (early‐night: −3.8 ± 3.3 cmH(2)O; late‐night: −2.6 ± 3.0 cmH(2)O; P = 0.03) and APmean decreased (evening: 4.2 ± 1.3 cm(2); morning: 3.7 ± 1.3 cm(2); P = 0.006). The total AHI correlated with neck circumference (r = 0.4; P = 0.04) and Pcrit (r = 0.5; P = 0.01). APmean correlated with neck circumference (r = −0.47; P = 0.02). There was no significant change in AHI between the first and second half of the night (first‐half: 12.9 ± 12.4/h; second‐half: 13.7 ± 13.3/h; P = 0.6). Overnight rostral fluid shift was associated with increased pharyngeal collapsibility and decreased pharyngeal caliber during sleep in CHF patients. Rostral fluid shift may be an important mechanism of OSA in this patient group.
format Online
Article
Text
id pubmed-5256151
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-52561512017-01-26 Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure Carlisle, Tom Ward, Neil R. Atalla, Angela Cowie, Martin R. Simonds, Anita K. Morrell, Mary J. Physiol Rep Original Research The increased prevalence of obstructive sleep apnea (OSA) in congestive heart failure (CHF) may be associated with rostral fluid shift. We investigated the effect of overnight rostral fluid shift on pharyngeal collapsibility (Pcrit), pharyngeal caliber (APmean), and apnea‐hypopnea index (AHI) in CHF patients. Twenty‐three optimally treated systolic CHF patients were studied. Neck circumference was measured immediately prior to sleep in the evening and immediately after waking in the morning as a marker of rostral fluid shift. Pcrit was measured during sleep, early and late in the night. APmean was measured using acoustic reflection at the same times as neck circumference measurements. 15/23 CHF patients experienced an overnight increase in neck circumference; overall neck circumference significantly increased overnight (mean±SD, evening: 41.7 ± 3.2 cm; morning: 42.3 ± 3.1 cm; P = 0.03). Pcrit increased significantly overnight (early‐night: −3.8 ± 3.3 cmH(2)O; late‐night: −2.6 ± 3.0 cmH(2)O; P = 0.03) and APmean decreased (evening: 4.2 ± 1.3 cm(2); morning: 3.7 ± 1.3 cm(2); P = 0.006). The total AHI correlated with neck circumference (r = 0.4; P = 0.04) and Pcrit (r = 0.5; P = 0.01). APmean correlated with neck circumference (r = −0.47; P = 0.02). There was no significant change in AHI between the first and second half of the night (first‐half: 12.9 ± 12.4/h; second‐half: 13.7 ± 13.3/h; P = 0.6). Overnight rostral fluid shift was associated with increased pharyngeal collapsibility and decreased pharyngeal caliber during sleep in CHF patients. Rostral fluid shift may be an important mechanism of OSA in this patient group. John Wiley and Sons Inc. 2017-01-05 /pmc/articles/PMC5256151/ /pubmed/28057850 http://dx.doi.org/10.14814/phy2.12956 Text en © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Carlisle, Tom
Ward, Neil R.
Atalla, Angela
Cowie, Martin R.
Simonds, Anita K.
Morrell, Mary J.
Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure
title Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure
title_full Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure
title_fullStr Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure
title_full_unstemmed Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure
title_short Investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure
title_sort investigation of the link between fluid shift and airway collapsibility as a mechanism for obstructive sleep apnea in congestive heart failure
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5256151/
https://www.ncbi.nlm.nih.gov/pubmed/28057850
http://dx.doi.org/10.14814/phy2.12956
work_keys_str_mv AT carlisletom investigationofthelinkbetweenfluidshiftandairwaycollapsibilityasamechanismforobstructivesleepapneaincongestiveheartfailure
AT wardneilr investigationofthelinkbetweenfluidshiftandairwaycollapsibilityasamechanismforobstructivesleepapneaincongestiveheartfailure
AT atallaangela investigationofthelinkbetweenfluidshiftandairwaycollapsibilityasamechanismforobstructivesleepapneaincongestiveheartfailure
AT cowiemartinr investigationofthelinkbetweenfluidshiftandairwaycollapsibilityasamechanismforobstructivesleepapneaincongestiveheartfailure
AT simondsanitak investigationofthelinkbetweenfluidshiftandairwaycollapsibilityasamechanismforobstructivesleepapneaincongestiveheartfailure
AT morrellmaryj investigationofthelinkbetweenfluidshiftandairwaycollapsibilityasamechanismforobstructivesleepapneaincongestiveheartfailure