Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography

PURPOSE: It is not known if outflow facilities measured by pneumatonography and Schiøtz tonography are interchangeable. In this study we compared outflow facility measured by pneumatonography to outflow facility measured by digital Schiøtz tonography. METHODS: Fifty-six eyes from 28 healthy particip...

Descripción completa

Detalles Bibliográficos
Autores principales: Kazemi, Arash, McLaren, Jay W., Lin, Shuai-Chun, Toris, Carol B., Gulati, Vikas, Moroi, Sayoko E., Sit, Arthur J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5256680/
https://www.ncbi.nlm.nih.gov/pubmed/28114581
http://dx.doi.org/10.1167/iovs.16-20754
_version_ 1782498733113475072
author Kazemi, Arash
McLaren, Jay W.
Lin, Shuai-Chun
Toris, Carol B.
Gulati, Vikas
Moroi, Sayoko E.
Sit, Arthur J.
author_facet Kazemi, Arash
McLaren, Jay W.
Lin, Shuai-Chun
Toris, Carol B.
Gulati, Vikas
Moroi, Sayoko E.
Sit, Arthur J.
author_sort Kazemi, Arash
collection PubMed
description PURPOSE: It is not known if outflow facilities measured by pneumatonography and Schiøtz tonography are interchangeable. In this study we compared outflow facility measured by pneumatonography to outflow facility measured by digital Schiøtz tonography. METHODS: Fifty-six eyes from 28 healthy participants, ages 41 to 68 years, were included. Intraocular pressure (IOP) was measured in the sitting and supine positions with a pneumatonometer. With the subject in the supine position, IOP was recorded for 2 minutes by using a pneumatonometer with a 10-g weight and for 4 minutes by using a custom digital Schiøtz tonometer. Outflow facility was determined from the changes in pressure and intraocular volume and a standard assumed ocular rigidity coefficient for each instrument, respectively, and by using an ocular rigidity coefficient calculated by measuring pressure without and with a weight added to the pneumatonometer tip. RESULTS: The outflow facility was 0.29 ± 0.09 μL/min/mm Hg by Schiøtz tonography and 0.24 ± 0.08 μL/min/mm Hg by pneumatonography (P < 0.001) when using the standard assumed constant ocular rigidity coefficient. Mean calculated ocular rigidity coefficient was 0.028 ± 0.01 μL(−1), and outflow facility determined by using this coefficient was 0.23 ± 0.08 μL/min/mm Hg by Schiøtz tonography and 0.21 ± 0.07 μL/min/mm Hg by pneumatonography (P = 0.003). Outflow facilities measured by the two devices were correlated when the ocular rigidity was assumed (r = 0.60, P < 0.001) or calculated (r = 0.70, P < 0.001). CONCLUSIONS: Outflow facilities measured by pneumatonography were correlated with those measured by Schiøtz tonography, but Schiøtz tonography reported approximately 10% to 20% higher facilities when using the standard method. When ocular rigidity was determined for each eye, differences were smaller. Measurements from these devices cannot be compared directly.
format Online
Article
Text
id pubmed-5256680
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-52566802017-01-25 Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography Kazemi, Arash McLaren, Jay W. Lin, Shuai-Chun Toris, Carol B. Gulati, Vikas Moroi, Sayoko E. Sit, Arthur J. Invest Ophthalmol Vis Sci Glaucoma PURPOSE: It is not known if outflow facilities measured by pneumatonography and Schiøtz tonography are interchangeable. In this study we compared outflow facility measured by pneumatonography to outflow facility measured by digital Schiøtz tonography. METHODS: Fifty-six eyes from 28 healthy participants, ages 41 to 68 years, were included. Intraocular pressure (IOP) was measured in the sitting and supine positions with a pneumatonometer. With the subject in the supine position, IOP was recorded for 2 minutes by using a pneumatonometer with a 10-g weight and for 4 minutes by using a custom digital Schiøtz tonometer. Outflow facility was determined from the changes in pressure and intraocular volume and a standard assumed ocular rigidity coefficient for each instrument, respectively, and by using an ocular rigidity coefficient calculated by measuring pressure without and with a weight added to the pneumatonometer tip. RESULTS: The outflow facility was 0.29 ± 0.09 μL/min/mm Hg by Schiøtz tonography and 0.24 ± 0.08 μL/min/mm Hg by pneumatonography (P < 0.001) when using the standard assumed constant ocular rigidity coefficient. Mean calculated ocular rigidity coefficient was 0.028 ± 0.01 μL(−1), and outflow facility determined by using this coefficient was 0.23 ± 0.08 μL/min/mm Hg by Schiøtz tonography and 0.21 ± 0.07 μL/min/mm Hg by pneumatonography (P = 0.003). Outflow facilities measured by the two devices were correlated when the ocular rigidity was assumed (r = 0.60, P < 0.001) or calculated (r = 0.70, P < 0.001). CONCLUSIONS: Outflow facilities measured by pneumatonography were correlated with those measured by Schiøtz tonography, but Schiøtz tonography reported approximately 10% to 20% higher facilities when using the standard method. When ocular rigidity was determined for each eye, differences were smaller. Measurements from these devices cannot be compared directly. The Association for Research in Vision and Ophthalmology 2017-01 /pmc/articles/PMC5256680/ /pubmed/28114581 http://dx.doi.org/10.1167/iovs.16-20754 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Glaucoma
Kazemi, Arash
McLaren, Jay W.
Lin, Shuai-Chun
Toris, Carol B.
Gulati, Vikas
Moroi, Sayoko E.
Sit, Arthur J.
Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
title Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
title_full Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
title_fullStr Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
title_full_unstemmed Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
title_short Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
title_sort comparison of aqueous outflow facility measurement by pneumatonography and digital schiøtz tonography
topic Glaucoma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5256680/
https://www.ncbi.nlm.nih.gov/pubmed/28114581
http://dx.doi.org/10.1167/iovs.16-20754
work_keys_str_mv AT kazemiarash comparisonofaqueousoutflowfacilitymeasurementbypneumatonographyanddigitalschiøtztonography
AT mclarenjayw comparisonofaqueousoutflowfacilitymeasurementbypneumatonographyanddigitalschiøtztonography
AT linshuaichun comparisonofaqueousoutflowfacilitymeasurementbypneumatonographyanddigitalschiøtztonography
AT toriscarolb comparisonofaqueousoutflowfacilitymeasurementbypneumatonographyanddigitalschiøtztonography
AT gulativikas comparisonofaqueousoutflowfacilitymeasurementbypneumatonographyanddigitalschiøtztonography
AT moroisayokoe comparisonofaqueousoutflowfacilitymeasurementbypneumatonographyanddigitalschiøtztonography
AT sitarthurj comparisonofaqueousoutflowfacilitymeasurementbypneumatonographyanddigitalschiøtztonography