Cargando…
Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI
OBJECTIVE: Arterial spin-labelling (ASL) MRI uses intrinsic blood water to quantify the cerebral blood flow (CBF), removing the need for the injection of a gadolinium-based contrast agent used for conventional perfusion imaging such as dynamic susceptibility contrast (DSC). Owing to the non-invasive...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Institute of Radiology.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5258143/ https://www.ncbi.nlm.nih.gov/pubmed/26975495 http://dx.doi.org/10.1259/bjr.20150624 |
_version_ | 1782498992310976512 |
---|---|
author | Vidyasagar, Rishma Abernethy, Laurence Pizer, Barry Avula, Shivaram Parkes, Laura M |
author_facet | Vidyasagar, Rishma Abernethy, Laurence Pizer, Barry Avula, Shivaram Parkes, Laura M |
author_sort | Vidyasagar, Rishma |
collection | PubMed |
description | OBJECTIVE: Arterial spin-labelling (ASL) MRI uses intrinsic blood water to quantify the cerebral blood flow (CBF), removing the need for the injection of a gadolinium-based contrast agent used for conventional perfusion imaging such as dynamic susceptibility contrast (DSC). Owing to the non-invasive nature of the technique, ASL is an attractive option for use in paediatric patients. This work compared DSC and multi-timepoint ASL measures of CBF in paediatric brain tumours. METHODS: Patients (n = 23; 20 low-grade tumours and 3 high-grade tumours) had DSC and multi-timepoint ASL with and without vascular crushers (VC). VC removes the contribution from larger vessel blood flow. Mean perfusion metrics were extracted from control and T(1)-enhanced tumour regions of interest (ROIs): arterial arrival time (AAT) and CBF from the ASL images with and without VC, relative cerebral blood flow (rCBF), relative cerebral blood volume, delay time (DT) and mean transit time (MTT) from the DSC images. RESULTS: Significant correlations existed for: AAT and DT (r = 0.77, p = 0.0002) and CBF and rCBF (r = 0.56, p = 0.02) in control ROIs for ASL-noVC. No significant correlations existed between DSC and ASL measures in the tumour region. Significant differences between control and tumour ROI were found for MTT (p < 0.001) and rCBF (p < 0.005) measures. CONCLUSION: Significant correlations between ASL-noVC and DSC measures in the normal brain suggest that DSC is most sensitive to macrovascular blood flow. The absence of significant correlations within the tumour ROI suggests that ASL is sensitive to different physiological mechanisms compared with DSC measures. ADVANCES IN KNOWLEDGE: ASL provides information which is comparable with that of DSC in healthy tissues, but appears to reflect a different physiology in tumour tissues. |
format | Online Article Text |
id | pubmed-5258143 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The British Institute of Radiology. |
record_format | MEDLINE/PubMed |
spelling | pubmed-52581432017-02-02 Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI Vidyasagar, Rishma Abernethy, Laurence Pizer, Barry Avula, Shivaram Parkes, Laura M Br J Radiol Full Paper OBJECTIVE: Arterial spin-labelling (ASL) MRI uses intrinsic blood water to quantify the cerebral blood flow (CBF), removing the need for the injection of a gadolinium-based contrast agent used for conventional perfusion imaging such as dynamic susceptibility contrast (DSC). Owing to the non-invasive nature of the technique, ASL is an attractive option for use in paediatric patients. This work compared DSC and multi-timepoint ASL measures of CBF in paediatric brain tumours. METHODS: Patients (n = 23; 20 low-grade tumours and 3 high-grade tumours) had DSC and multi-timepoint ASL with and without vascular crushers (VC). VC removes the contribution from larger vessel blood flow. Mean perfusion metrics were extracted from control and T(1)-enhanced tumour regions of interest (ROIs): arterial arrival time (AAT) and CBF from the ASL images with and without VC, relative cerebral blood flow (rCBF), relative cerebral blood volume, delay time (DT) and mean transit time (MTT) from the DSC images. RESULTS: Significant correlations existed for: AAT and DT (r = 0.77, p = 0.0002) and CBF and rCBF (r = 0.56, p = 0.02) in control ROIs for ASL-noVC. No significant correlations existed between DSC and ASL measures in the tumour region. Significant differences between control and tumour ROI were found for MTT (p < 0.001) and rCBF (p < 0.005) measures. CONCLUSION: Significant correlations between ASL-noVC and DSC measures in the normal brain suggest that DSC is most sensitive to macrovascular blood flow. The absence of significant correlations within the tumour ROI suggests that ASL is sensitive to different physiological mechanisms compared with DSC measures. ADVANCES IN KNOWLEDGE: ASL provides information which is comparable with that of DSC in healthy tissues, but appears to reflect a different physiology in tumour tissues. The British Institute of Radiology. 2016-06 2016-04-11 /pmc/articles/PMC5258143/ /pubmed/26975495 http://dx.doi.org/10.1259/bjr.20150624 Text en © 2016 The Authors. Published by the British Institute of Radiology This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 Unported License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Full Paper Vidyasagar, Rishma Abernethy, Laurence Pizer, Barry Avula, Shivaram Parkes, Laura M Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI |
title | Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI |
title_full | Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI |
title_fullStr | Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI |
title_full_unstemmed | Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI |
title_short | Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI |
title_sort | quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled mri |
topic | Full Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5258143/ https://www.ncbi.nlm.nih.gov/pubmed/26975495 http://dx.doi.org/10.1259/bjr.20150624 |
work_keys_str_mv | AT vidyasagarrishma quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri AT abernethylaurence quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri AT pizerbarry quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri AT avulashivaram quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri AT parkeslauram quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri |