Cargando…

Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI

OBJECTIVE: Arterial spin-labelling (ASL) MRI uses intrinsic blood water to quantify the cerebral blood flow (CBF), removing the need for the injection of a gadolinium-based contrast agent used for conventional perfusion imaging such as dynamic susceptibility contrast (DSC). Owing to the non-invasive...

Descripción completa

Detalles Bibliográficos
Autores principales: Vidyasagar, Rishma, Abernethy, Laurence, Pizer, Barry, Avula, Shivaram, Parkes, Laura M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Institute of Radiology. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5258143/
https://www.ncbi.nlm.nih.gov/pubmed/26975495
http://dx.doi.org/10.1259/bjr.20150624
_version_ 1782498992310976512
author Vidyasagar, Rishma
Abernethy, Laurence
Pizer, Barry
Avula, Shivaram
Parkes, Laura M
author_facet Vidyasagar, Rishma
Abernethy, Laurence
Pizer, Barry
Avula, Shivaram
Parkes, Laura M
author_sort Vidyasagar, Rishma
collection PubMed
description OBJECTIVE: Arterial spin-labelling (ASL) MRI uses intrinsic blood water to quantify the cerebral blood flow (CBF), removing the need for the injection of a gadolinium-based contrast agent used for conventional perfusion imaging such as dynamic susceptibility contrast (DSC). Owing to the non-invasive nature of the technique, ASL is an attractive option for use in paediatric patients. This work compared DSC and multi-timepoint ASL measures of CBF in paediatric brain tumours. METHODS: Patients (n = 23; 20 low-grade tumours and 3 high-grade tumours) had DSC and multi-timepoint ASL with and without vascular crushers (VC). VC removes the contribution from larger vessel blood flow. Mean perfusion metrics were extracted from control and T(1)-enhanced tumour regions of interest (ROIs): arterial arrival time (AAT) and CBF from the ASL images with and without VC, relative cerebral blood flow (rCBF), relative cerebral blood volume, delay time (DT) and mean transit time (MTT) from the DSC images. RESULTS: Significant correlations existed for: AAT and DT (r = 0.77, p = 0.0002) and CBF and rCBF (r = 0.56, p = 0.02) in control ROIs for ASL-noVC. No significant correlations existed between DSC and ASL measures in the tumour region. Significant differences between control and tumour ROI were found for MTT (p < 0.001) and rCBF (p < 0.005) measures. CONCLUSION: Significant correlations between ASL-noVC and DSC measures in the normal brain suggest that DSC is most sensitive to macrovascular blood flow. The absence of significant correlations within the tumour ROI suggests that ASL is sensitive to different physiological mechanisms compared with DSC measures. ADVANCES IN KNOWLEDGE: ASL provides information which is comparable with that of DSC in healthy tissues, but appears to reflect a different physiology in tumour tissues.
format Online
Article
Text
id pubmed-5258143
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The British Institute of Radiology.
record_format MEDLINE/PubMed
spelling pubmed-52581432017-02-02 Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI Vidyasagar, Rishma Abernethy, Laurence Pizer, Barry Avula, Shivaram Parkes, Laura M Br J Radiol Full Paper OBJECTIVE: Arterial spin-labelling (ASL) MRI uses intrinsic blood water to quantify the cerebral blood flow (CBF), removing the need for the injection of a gadolinium-based contrast agent used for conventional perfusion imaging such as dynamic susceptibility contrast (DSC). Owing to the non-invasive nature of the technique, ASL is an attractive option for use in paediatric patients. This work compared DSC and multi-timepoint ASL measures of CBF in paediatric brain tumours. METHODS: Patients (n = 23; 20 low-grade tumours and 3 high-grade tumours) had DSC and multi-timepoint ASL with and without vascular crushers (VC). VC removes the contribution from larger vessel blood flow. Mean perfusion metrics were extracted from control and T(1)-enhanced tumour regions of interest (ROIs): arterial arrival time (AAT) and CBF from the ASL images with and without VC, relative cerebral blood flow (rCBF), relative cerebral blood volume, delay time (DT) and mean transit time (MTT) from the DSC images. RESULTS: Significant correlations existed for: AAT and DT (r = 0.77, p = 0.0002) and CBF and rCBF (r = 0.56, p = 0.02) in control ROIs for ASL-noVC. No significant correlations existed between DSC and ASL measures in the tumour region. Significant differences between control and tumour ROI were found for MTT (p < 0.001) and rCBF (p < 0.005) measures. CONCLUSION: Significant correlations between ASL-noVC and DSC measures in the normal brain suggest that DSC is most sensitive to macrovascular blood flow. The absence of significant correlations within the tumour ROI suggests that ASL is sensitive to different physiological mechanisms compared with DSC measures. ADVANCES IN KNOWLEDGE: ASL provides information which is comparable with that of DSC in healthy tissues, but appears to reflect a different physiology in tumour tissues. The British Institute of Radiology. 2016-06 2016-04-11 /pmc/articles/PMC5258143/ /pubmed/26975495 http://dx.doi.org/10.1259/bjr.20150624 Text en © 2016 The Authors. Published by the British Institute of Radiology This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 Unported License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
spellingShingle Full Paper
Vidyasagar, Rishma
Abernethy, Laurence
Pizer, Barry
Avula, Shivaram
Parkes, Laura M
Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI
title Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI
title_full Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI
title_fullStr Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI
title_full_unstemmed Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI
title_short Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI
title_sort quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled mri
topic Full Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5258143/
https://www.ncbi.nlm.nih.gov/pubmed/26975495
http://dx.doi.org/10.1259/bjr.20150624
work_keys_str_mv AT vidyasagarrishma quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri
AT abernethylaurence quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri
AT pizerbarry quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri
AT avulashivaram quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri
AT parkeslauram quantitativemeasurementofbloodflowinpaediatricbraintumoursacomparativestudyofdynamicsusceptibilitycontrastandmultitimepointarterialspinlabelledmri