Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry
A matrix removal procedure with ion-exchange resin prior to analysis for 18 fluorinated benzoic acids (FBAs) tracers in saline (>25% salt) reservoir water was optimized. The elimination of >98% of salt and the simultaneous matrix sample cleanup allowed the direct analysis using the supernatant...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5258790/ https://www.ncbi.nlm.nih.gov/pubmed/27832302 http://dx.doi.org/10.1007/s00216-016-0060-5 |
_version_ | 1782499092500316160 |
---|---|
author | Kubica, Paweł Vacchina, Véronique Wasilewski, Tomasz Reynaud, Stéphanie Szpunar, Joanna Lobinski, Ryszard |
author_facet | Kubica, Paweł Vacchina, Véronique Wasilewski, Tomasz Reynaud, Stéphanie Szpunar, Joanna Lobinski, Ryszard |
author_sort | Kubica, Paweł |
collection | PubMed |
description | A matrix removal procedure with ion-exchange resin prior to analysis for 18 fluorinated benzoic acids (FBAs) tracers in saline (>25% salt) reservoir water was optimized. The elimination of >98% of salt and the simultaneous matrix sample cleanup allowed the direct analysis using the supernatant by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). This resulted in a gain in detection limits for most of the tracers in comparison with the reference method (direct analysis after minimum required dilution). The limits of detection (LODs) were in the range of 0.01–0.15 ng/ml and compared to other studies the developed method provided comparable limits of detection and advantage of simplified and shorter sample preparation. The presented method offers a considerable gain in simplicity and analysis time. Recoveries for all the tracers reached 80–100%, except for 2-FBA and 2,6-dFBA for which they were ca. 60%. The low recoveries were corrected by the use of five isotopically labeled internal standards. The method was validated by the analysis of spiked samples and by an independent comparison of the results with those obtained by solid-phase extraction LC-MS/MS method. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-016-0060-5) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5258790 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-52587902017-02-06 Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry Kubica, Paweł Vacchina, Véronique Wasilewski, Tomasz Reynaud, Stéphanie Szpunar, Joanna Lobinski, Ryszard Anal Bioanal Chem Rapid Communication A matrix removal procedure with ion-exchange resin prior to analysis for 18 fluorinated benzoic acids (FBAs) tracers in saline (>25% salt) reservoir water was optimized. The elimination of >98% of salt and the simultaneous matrix sample cleanup allowed the direct analysis using the supernatant by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). This resulted in a gain in detection limits for most of the tracers in comparison with the reference method (direct analysis after minimum required dilution). The limits of detection (LODs) were in the range of 0.01–0.15 ng/ml and compared to other studies the developed method provided comparable limits of detection and advantage of simplified and shorter sample preparation. The presented method offers a considerable gain in simplicity and analysis time. Recoveries for all the tracers reached 80–100%, except for 2-FBA and 2,6-dFBA for which they were ca. 60%. The low recoveries were corrected by the use of five isotopically labeled internal standards. The method was validated by the analysis of spiked samples and by an independent comparison of the results with those obtained by solid-phase extraction LC-MS/MS method. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-016-0060-5) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2016-11-10 2017 /pmc/articles/PMC5258790/ /pubmed/27832302 http://dx.doi.org/10.1007/s00216-016-0060-5 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Rapid Communication Kubica, Paweł Vacchina, Véronique Wasilewski, Tomasz Reynaud, Stéphanie Szpunar, Joanna Lobinski, Ryszard Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry |
title | Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry |
title_full | Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry |
title_fullStr | Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry |
title_full_unstemmed | Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry |
title_short | Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry |
title_sort | rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry |
topic | Rapid Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5258790/ https://www.ncbi.nlm.nih.gov/pubmed/27832302 http://dx.doi.org/10.1007/s00216-016-0060-5 |
work_keys_str_mv | AT kubicapaweł rapidionexchangematrixremovalforadecreaseofdetectionlimitsintheanalysisofsaltrichreservoirwatersforfluorobenzoicacidsbyliquidchromatographycoupledwithtandemmassspectrometry AT vacchinaveronique rapidionexchangematrixremovalforadecreaseofdetectionlimitsintheanalysisofsaltrichreservoirwatersforfluorobenzoicacidsbyliquidchromatographycoupledwithtandemmassspectrometry AT wasilewskitomasz rapidionexchangematrixremovalforadecreaseofdetectionlimitsintheanalysisofsaltrichreservoirwatersforfluorobenzoicacidsbyliquidchromatographycoupledwithtandemmassspectrometry AT reynaudstephanie rapidionexchangematrixremovalforadecreaseofdetectionlimitsintheanalysisofsaltrichreservoirwatersforfluorobenzoicacidsbyliquidchromatographycoupledwithtandemmassspectrometry AT szpunarjoanna rapidionexchangematrixremovalforadecreaseofdetectionlimitsintheanalysisofsaltrichreservoirwatersforfluorobenzoicacidsbyliquidchromatographycoupledwithtandemmassspectrometry AT lobinskiryszard rapidionexchangematrixremovalforadecreaseofdetectionlimitsintheanalysisofsaltrichreservoirwatersforfluorobenzoicacidsbyliquidchromatographycoupledwithtandemmassspectrometry |