Cargando…
Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
AIMS: Visual guidance through echocardiography and fluoroscopy is crucial for a successful transseptal puncture (TSP) in a prespecified region of the fossa ovalis. The novel EchoNavigator system Release II (EchoNav II, Philips Healthcare, Andover, Massachusetts, USA) enables the real-time fusion of...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260626/ https://www.ncbi.nlm.nih.gov/pubmed/27966185 http://dx.doi.org/10.1007/s12471-016-0937-0 |
_version_ | 1782499438510473216 |
---|---|
author | Afzal, S. Veulemans, V. Balzer, J. Rassaf, T. Hellhammer, K. Polzin, A. Kelm, M. Zeus, T. |
author_facet | Afzal, S. Veulemans, V. Balzer, J. Rassaf, T. Hellhammer, K. Polzin, A. Kelm, M. Zeus, T. |
author_sort | Afzal, S. |
collection | PubMed |
description | AIMS: Visual guidance through echocardiography and fluoroscopy is crucial for a successful transseptal puncture (TSP) in a prespecified region of the fossa ovalis. The novel EchoNavigator system Release II (EchoNav II, Philips Healthcare, Andover, Massachusetts, USA) enables the real-time fusion of fluoroscopic and echocardiographic images. We evaluated this new imaging method in respect to safety and efficacy of TSP during MitraClip implantation and left atrial appendage closure. METHODS: Forty-four patients before (−EchoNav) and 44 patients after (+EchoNav) the introduction of real-time fusion were included in our retrospective, single-centre study. The primary endpoint was the occurrence of adverse events due to TSP. Secondary endpoints were successful puncture at the prespecified region and time until TSP (min). RESULTS: In both groups TSP was performed successfully in the prespecified region and no adverse events occurred during or due to the accomplishment of TSP. Time until TSP was significantly reduced in the +EchoNav group in comparison with the EchoNav group (18.48 ± 5.62 min vs. 23.20 ± 9.61 min, p = 0.006). CONCLUSIONS: Real-time fusion of echocardiography and fluoroscopy proved to be as safe and successful as standard best practice for TSP. Moreover, efficacy was improved through significant reduction of time until TSP. |
format | Online Article Text |
id | pubmed-5260626 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-52606262017-02-06 Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy Afzal, S. Veulemans, V. Balzer, J. Rassaf, T. Hellhammer, K. Polzin, A. Kelm, M. Zeus, T. Neth Heart J Original Article - Design Study Article AIMS: Visual guidance through echocardiography and fluoroscopy is crucial for a successful transseptal puncture (TSP) in a prespecified region of the fossa ovalis. The novel EchoNavigator system Release II (EchoNav II, Philips Healthcare, Andover, Massachusetts, USA) enables the real-time fusion of fluoroscopic and echocardiographic images. We evaluated this new imaging method in respect to safety and efficacy of TSP during MitraClip implantation and left atrial appendage closure. METHODS: Forty-four patients before (−EchoNav) and 44 patients after (+EchoNav) the introduction of real-time fusion were included in our retrospective, single-centre study. The primary endpoint was the occurrence of adverse events due to TSP. Secondary endpoints were successful puncture at the prespecified region and time until TSP (min). RESULTS: In both groups TSP was performed successfully in the prespecified region and no adverse events occurred during or due to the accomplishment of TSP. Time until TSP was significantly reduced in the +EchoNav group in comparison with the EchoNav group (18.48 ± 5.62 min vs. 23.20 ± 9.61 min, p = 0.006). CONCLUSIONS: Real-time fusion of echocardiography and fluoroscopy proved to be as safe and successful as standard best practice for TSP. Moreover, efficacy was improved through significant reduction of time until TSP. Bohn Stafleu van Loghum 2016-12-13 2017-02 /pmc/articles/PMC5260626/ /pubmed/27966185 http://dx.doi.org/10.1007/s12471-016-0937-0 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article - Design Study Article Afzal, S. Veulemans, V. Balzer, J. Rassaf, T. Hellhammer, K. Polzin, A. Kelm, M. Zeus, T. Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy |
title | Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy |
title_full | Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy |
title_fullStr | Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy |
title_full_unstemmed | Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy |
title_short | Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy |
title_sort | safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy |
topic | Original Article - Design Study Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260626/ https://www.ncbi.nlm.nih.gov/pubmed/27966185 http://dx.doi.org/10.1007/s12471-016-0937-0 |
work_keys_str_mv | AT afzals safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy AT veulemansv safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy AT balzerj safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy AT rassaft safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy AT hellhammerk safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy AT polzina safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy AT kelmm safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy AT zeust safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy |