Cargando…

Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy

AIMS: Visual guidance through echocardiography and fluoroscopy is crucial for a successful transseptal puncture (TSP) in a prespecified region of the fossa ovalis. The novel EchoNavigator system Release II (EchoNav II, Philips Healthcare, Andover, Massachusetts, USA) enables the real-time fusion of...

Descripción completa

Detalles Bibliográficos
Autores principales: Afzal, S., Veulemans, V., Balzer, J., Rassaf, T., Hellhammer, K., Polzin, A., Kelm, M., Zeus, T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260626/
https://www.ncbi.nlm.nih.gov/pubmed/27966185
http://dx.doi.org/10.1007/s12471-016-0937-0
_version_ 1782499438510473216
author Afzal, S.
Veulemans, V.
Balzer, J.
Rassaf, T.
Hellhammer, K.
Polzin, A.
Kelm, M.
Zeus, T.
author_facet Afzal, S.
Veulemans, V.
Balzer, J.
Rassaf, T.
Hellhammer, K.
Polzin, A.
Kelm, M.
Zeus, T.
author_sort Afzal, S.
collection PubMed
description AIMS: Visual guidance through echocardiography and fluoroscopy is crucial for a successful transseptal puncture (TSP) in a prespecified region of the fossa ovalis. The novel EchoNavigator system Release II (EchoNav II, Philips Healthcare, Andover, Massachusetts, USA) enables the real-time fusion of fluoroscopic and echocardiographic images. We evaluated this new imaging method in respect to safety and efficacy of TSP during MitraClip implantation and left atrial appendage closure. METHODS: Forty-four patients before (−EchoNav) and 44 patients after (+EchoNav) the introduction of real-time fusion were included in our retrospective, single-centre study. The primary endpoint was the occurrence of adverse events due to TSP. Secondary endpoints were successful puncture at the prespecified region and time until TSP (min). RESULTS: In both groups TSP was performed successfully in the prespecified region and no adverse events occurred during or due to the accomplishment of TSP. Time until TSP was significantly reduced in the +EchoNav group in comparison with the EchoNav group (18.48 ± 5.62 min vs. 23.20 ± 9.61 min, p = 0.006). CONCLUSIONS: Real-time fusion of echocardiography and fluoroscopy proved to be as safe and successful as standard best practice for TSP. Moreover, efficacy was improved through significant reduction of time until TSP.
format Online
Article
Text
id pubmed-5260626
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-52606262017-02-06 Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy Afzal, S. Veulemans, V. Balzer, J. Rassaf, T. Hellhammer, K. Polzin, A. Kelm, M. Zeus, T. Neth Heart J Original Article - Design Study Article AIMS: Visual guidance through echocardiography and fluoroscopy is crucial for a successful transseptal puncture (TSP) in a prespecified region of the fossa ovalis. The novel EchoNavigator system Release II (EchoNav II, Philips Healthcare, Andover, Massachusetts, USA) enables the real-time fusion of fluoroscopic and echocardiographic images. We evaluated this new imaging method in respect to safety and efficacy of TSP during MitraClip implantation and left atrial appendage closure. METHODS: Forty-four patients before (−EchoNav) and 44 patients after (+EchoNav) the introduction of real-time fusion were included in our retrospective, single-centre study. The primary endpoint was the occurrence of adverse events due to TSP. Secondary endpoints were successful puncture at the prespecified region and time until TSP (min). RESULTS: In both groups TSP was performed successfully in the prespecified region and no adverse events occurred during or due to the accomplishment of TSP. Time until TSP was significantly reduced in the +EchoNav group in comparison with the EchoNav group (18.48 ± 5.62 min vs. 23.20 ± 9.61 min, p = 0.006). CONCLUSIONS: Real-time fusion of echocardiography and fluoroscopy proved to be as safe and successful as standard best practice for TSP. Moreover, efficacy was improved through significant reduction of time until TSP. Bohn Stafleu van Loghum 2016-12-13 2017-02 /pmc/articles/PMC5260626/ /pubmed/27966185 http://dx.doi.org/10.1007/s12471-016-0937-0 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article - Design Study Article
Afzal, S.
Veulemans, V.
Balzer, J.
Rassaf, T.
Hellhammer, K.
Polzin, A.
Kelm, M.
Zeus, T.
Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
title Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
title_full Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
title_fullStr Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
title_full_unstemmed Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
title_short Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
title_sort safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy
topic Original Article - Design Study Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260626/
https://www.ncbi.nlm.nih.gov/pubmed/27966185
http://dx.doi.org/10.1007/s12471-016-0937-0
work_keys_str_mv AT afzals safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy
AT veulemansv safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy
AT balzerj safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy
AT rassaft safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy
AT hellhammerk safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy
AT polzina safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy
AT kelmm safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy
AT zeust safetyandefficacyoftransseptalpunctureguidedbyrealtimefusionofechocardiographyandfluoroscopy