Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
INTRODUCTION: Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260627/ https://www.ncbi.nlm.nih.gov/pubmed/27966187 http://dx.doi.org/10.1007/s12471-016-0941-4 |
_version_ | 1782499438745354240 |
---|---|
author | Goreczny, S. Moszura, T. Dryzek, P. Lukaszewski, M. Krawczuk, A. Moll, J. Morgan, G. J. |
author_facet | Goreczny, S. Moszura, T. Dryzek, P. Lukaszewski, M. Krawczuk, A. Moll, J. Morgan, G. J. |
author_sort | Goreczny, S. |
collection | PubMed |
description | INTRODUCTION: Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pre-registered computed tomography or magnetic resonance imaging datasets, promising reductions in contrast and radiation exposure along with shorter procedural times. METHODS: In this retrospective review, patients were assigned to three groups according to the mode of imaging guidance: two-dimensional angiography (2DA), 3DRA and VesselNavigator (VN) assisted valve implantation. Patient characteristics and catheterisation data were reviewed with a focus on contrast and radiation exposure, fluoroscopy, and procedural times. RESULTS: Between July 2012 and June 2016, 21 patients underwent PPVI: 8 with 2D guidance, 6 patients with 3DRA and most recently 7 patients with VN assistance. Patents in the VN group received significantly less absolute and weight indexed contrast when compared with those with 2DA or 3DRA guided PPVI. Patients in the 2DA group received a significantly higher total dose area product radiation dose and air kerma in comparison with patients with 3DRA and VN guided intervention. Application of VN resulted in the shortest fluoroscopy time, although not statistically significant, and a significantly shorter study time when compared with 2DA. CONCLUSIONS: Utilisation of pre-intervention image manipulation with VesselNavigator for 3D guidance of PPVI results in a reduction in contrast and radiation exposure and study time as compared with traditional 2D guidance, and contrast usage as compared with 3DRA. |
format | Online Article Text |
id | pubmed-5260627 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-52606272017-02-06 Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance Goreczny, S. Moszura, T. Dryzek, P. Lukaszewski, M. Krawczuk, A. Moll, J. Morgan, G. J. Neth Heart J Original Article INTRODUCTION: Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pre-registered computed tomography or magnetic resonance imaging datasets, promising reductions in contrast and radiation exposure along with shorter procedural times. METHODS: In this retrospective review, patients were assigned to three groups according to the mode of imaging guidance: two-dimensional angiography (2DA), 3DRA and VesselNavigator (VN) assisted valve implantation. Patient characteristics and catheterisation data were reviewed with a focus on contrast and radiation exposure, fluoroscopy, and procedural times. RESULTS: Between July 2012 and June 2016, 21 patients underwent PPVI: 8 with 2D guidance, 6 patients with 3DRA and most recently 7 patients with VN assistance. Patents in the VN group received significantly less absolute and weight indexed contrast when compared with those with 2DA or 3DRA guided PPVI. Patients in the 2DA group received a significantly higher total dose area product radiation dose and air kerma in comparison with patients with 3DRA and VN guided intervention. Application of VN resulted in the shortest fluoroscopy time, although not statistically significant, and a significantly shorter study time when compared with 2DA. CONCLUSIONS: Utilisation of pre-intervention image manipulation with VesselNavigator for 3D guidance of PPVI results in a reduction in contrast and radiation exposure and study time as compared with traditional 2D guidance, and contrast usage as compared with 3DRA. Bohn Stafleu van Loghum 2016-12-13 2017-02 /pmc/articles/PMC5260627/ /pubmed/27966187 http://dx.doi.org/10.1007/s12471-016-0941-4 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Goreczny, S. Moszura, T. Dryzek, P. Lukaszewski, M. Krawczuk, A. Moll, J. Morgan, G. J. Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance |
title | Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance |
title_full | Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance |
title_fullStr | Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance |
title_full_unstemmed | Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance |
title_short | Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance |
title_sort | three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: a comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260627/ https://www.ncbi.nlm.nih.gov/pubmed/27966187 http://dx.doi.org/10.1007/s12471-016-0941-4 |
work_keys_str_mv | AT gorecznys threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance AT moszurat threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance AT dryzekp threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance AT lukaszewskim threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance AT krawczuka threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance AT mollj threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance AT morgangj threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance |