Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance

INTRODUCTION: Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Goreczny, S., Moszura, T., Dryzek, P., Lukaszewski, M., Krawczuk, A., Moll, J., Morgan, G. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260627/
https://www.ncbi.nlm.nih.gov/pubmed/27966187
http://dx.doi.org/10.1007/s12471-016-0941-4
_version_ 1782499438745354240
author Goreczny, S.
Moszura, T.
Dryzek, P.
Lukaszewski, M.
Krawczuk, A.
Moll, J.
Morgan, G. J.
author_facet Goreczny, S.
Moszura, T.
Dryzek, P.
Lukaszewski, M.
Krawczuk, A.
Moll, J.
Morgan, G. J.
author_sort Goreczny, S.
collection PubMed
description INTRODUCTION: Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pre-registered computed tomography or magnetic resonance imaging datasets, promising reductions in contrast and radiation exposure along with shorter procedural times. METHODS: In this retrospective review, patients were assigned to three groups according to the mode of imaging guidance: two-dimensional angiography (2DA), 3DRA and VesselNavigator (VN) assisted valve implantation. Patient characteristics and catheterisation data were reviewed with a focus on contrast and radiation exposure, fluoroscopy, and procedural times. RESULTS: Between July 2012 and June 2016, 21 patients underwent PPVI: 8 with 2D guidance, 6 patients with 3DRA and most recently 7 patients with VN assistance. Patents in the VN group received significantly less absolute and weight indexed contrast when compared with those with 2DA or 3DRA guided PPVI. Patients in the 2DA group received a significantly higher total dose area product radiation dose and air kerma in comparison with patients with 3DRA and VN guided intervention. Application of VN resulted in the shortest fluoroscopy time, although not statistically significant, and a significantly shorter study time when compared with 2DA. CONCLUSIONS: Utilisation of pre-intervention image manipulation with VesselNavigator for 3D guidance of PPVI results in a reduction in contrast and radiation exposure and study time as compared with traditional 2D guidance, and contrast usage as compared with 3DRA.
format Online
Article
Text
id pubmed-5260627
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-52606272017-02-06 Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance Goreczny, S. Moszura, T. Dryzek, P. Lukaszewski, M. Krawczuk, A. Moll, J. Morgan, G. J. Neth Heart J Original Article INTRODUCTION: Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pre-registered computed tomography or magnetic resonance imaging datasets, promising reductions in contrast and radiation exposure along with shorter procedural times. METHODS: In this retrospective review, patients were assigned to three groups according to the mode of imaging guidance: two-dimensional angiography (2DA), 3DRA and VesselNavigator (VN) assisted valve implantation. Patient characteristics and catheterisation data were reviewed with a focus on contrast and radiation exposure, fluoroscopy, and procedural times. RESULTS: Between July 2012 and June 2016, 21 patients underwent PPVI: 8 with 2D guidance, 6 patients with 3DRA and most recently 7 patients with VN assistance. Patents in the VN group received significantly less absolute and weight indexed contrast when compared with those with 2DA or 3DRA guided PPVI. Patients in the 2DA group received a significantly higher total dose area product radiation dose and air kerma in comparison with patients with 3DRA and VN guided intervention. Application of VN resulted in the shortest fluoroscopy time, although not statistically significant, and a significantly shorter study time when compared with 2DA. CONCLUSIONS: Utilisation of pre-intervention image manipulation with VesselNavigator for 3D guidance of PPVI results in a reduction in contrast and radiation exposure and study time as compared with traditional 2D guidance, and contrast usage as compared with 3DRA. Bohn Stafleu van Loghum 2016-12-13 2017-02 /pmc/articles/PMC5260627/ /pubmed/27966187 http://dx.doi.org/10.1007/s12471-016-0941-4 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Goreczny, S.
Moszura, T.
Dryzek, P.
Lukaszewski, M.
Krawczuk, A.
Moll, J.
Morgan, G. J.
Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
title Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
title_full Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
title_fullStr Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
title_full_unstemmed Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
title_short Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
title_sort three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: a comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260627/
https://www.ncbi.nlm.nih.gov/pubmed/27966187
http://dx.doi.org/10.1007/s12471-016-0941-4
work_keys_str_mv AT gorecznys threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance
AT moszurat threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance
AT dryzekp threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance
AT lukaszewskim threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance
AT krawczuka threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance
AT mollj threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance
AT morgangj threedimensionalimagefusionguidanceofpercutaneouspulmonaryvalveimplantationtoreduceradiationexposureandcontrastdoseacomparisonwithtraditionaltwodimensionalandthreedimensionalrotationalangiographicguidance