Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility

The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72...

Descripción completa

Detalles Bibliográficos
Autores principales: Dirnberger, Johannes, Wiesinger, Hans-Peter, Wiemer, Nicolas, Kösters, Alexander, Müller, Erich
Formato: Online Artículo Texto
Lenguaje:English
Publicado: De Gruyter 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260635/
https://www.ncbi.nlm.nih.gov/pubmed/28149337
http://dx.doi.org/10.1515/hukin-2015-0137
_version_ 1782499439636643840
author Dirnberger, Johannes
Wiesinger, Hans-Peter
Wiemer, Nicolas
Kösters, Alexander
Müller, Erich
author_facet Dirnberger, Johannes
Wiesinger, Hans-Peter
Wiemer, Nicolas
Kösters, Alexander
Müller, Erich
author_sort Dirnberger, Johannes
collection PubMed
description The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD(peak)) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD(peak) (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD(peak) as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse(0–30ms) and RTD/impulse(0–50ms)) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD(peak)-trial.
format Online
Article
Text
id pubmed-5260635
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher De Gruyter
record_format MEDLINE/PubMed
spelling pubmed-52606352017-02-01 Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility Dirnberger, Johannes Wiesinger, Hans-Peter Wiemer, Nicolas Kösters, Alexander Müller, Erich J Hum Kinet Research Article The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD(peak)) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD(peak) (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD(peak) as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse(0–30ms) and RTD/impulse(0–50ms)) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD(peak)-trial. De Gruyter 2016-04-13 /pmc/articles/PMC5260635/ /pubmed/28149337 http://dx.doi.org/10.1515/hukin-2015-0137 Text en © Editorial Committee of Journal of Human Kinetics
spellingShingle Research Article
Dirnberger, Johannes
Wiesinger, Hans-Peter
Wiemer, Nicolas
Kösters, Alexander
Müller, Erich
Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
title Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
title_full Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
title_fullStr Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
title_full_unstemmed Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
title_short Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
title_sort explosive strength of the knee extensors: the influence of criterion trial detection methodology on measurement reproducibility
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260635/
https://www.ncbi.nlm.nih.gov/pubmed/28149337
http://dx.doi.org/10.1515/hukin-2015-0137
work_keys_str_mv AT dirnbergerjohannes explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility
AT wiesingerhanspeter explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility
AT wiemernicolas explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility
AT kostersalexander explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility
AT mullererich explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility