Cargando…
Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
De Gruyter
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260635/ https://www.ncbi.nlm.nih.gov/pubmed/28149337 http://dx.doi.org/10.1515/hukin-2015-0137 |
_version_ | 1782499439636643840 |
---|---|
author | Dirnberger, Johannes Wiesinger, Hans-Peter Wiemer, Nicolas Kösters, Alexander Müller, Erich |
author_facet | Dirnberger, Johannes Wiesinger, Hans-Peter Wiemer, Nicolas Kösters, Alexander Müller, Erich |
author_sort | Dirnberger, Johannes |
collection | PubMed |
description | The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD(peak)) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD(peak) (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD(peak) as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse(0–30ms) and RTD/impulse(0–50ms)) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD(peak)-trial. |
format | Online Article Text |
id | pubmed-5260635 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | De Gruyter |
record_format | MEDLINE/PubMed |
spelling | pubmed-52606352017-02-01 Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility Dirnberger, Johannes Wiesinger, Hans-Peter Wiemer, Nicolas Kösters, Alexander Müller, Erich J Hum Kinet Research Article The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD(peak)) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD(peak) (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD(peak) as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse(0–30ms) and RTD/impulse(0–50ms)) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD(peak)-trial. De Gruyter 2016-04-13 /pmc/articles/PMC5260635/ /pubmed/28149337 http://dx.doi.org/10.1515/hukin-2015-0137 Text en © Editorial Committee of Journal of Human Kinetics |
spellingShingle | Research Article Dirnberger, Johannes Wiesinger, Hans-Peter Wiemer, Nicolas Kösters, Alexander Müller, Erich Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility |
title | Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility |
title_full | Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility |
title_fullStr | Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility |
title_full_unstemmed | Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility |
title_short | Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility |
title_sort | explosive strength of the knee extensors: the influence of criterion trial detection methodology on measurement reproducibility |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260635/ https://www.ncbi.nlm.nih.gov/pubmed/28149337 http://dx.doi.org/10.1515/hukin-2015-0137 |
work_keys_str_mv | AT dirnbergerjohannes explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility AT wiesingerhanspeter explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility AT wiemernicolas explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility AT kostersalexander explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility AT mullererich explosivestrengthofthekneeextensorstheinfluenceofcriteriontrialdetectionmethodologyonmeasurementreproducibility |