Cargando…

Flexible head-casts for high spatial precision MEG

BACKGROUND: In combination with magnetoencephalographic (MEG) data, accurate knowledge of the brain’s structure and location provide a principled way of reconstructing neural activity with high temporal resolution. However, measuring the brain’s location is compromised by head movement during scanni...

Descripción completa

Detalles Bibliográficos
Autores principales: Meyer, Sofie S., Bonaiuto, James, Lim, Mark, Rossiter, Holly, Waters, Sheena, Bradbury, David, Bestmann, Sven, Brookes, Matthew, Callaghan, Martina F., Weiskopf, Nikolaus, Barnes, Gareth R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier/North-Holland Biomedical Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260820/
https://www.ncbi.nlm.nih.gov/pubmed/27887969
http://dx.doi.org/10.1016/j.jneumeth.2016.11.009
Descripción
Sumario:BACKGROUND: In combination with magnetoencephalographic (MEG) data, accurate knowledge of the brain’s structure and location provide a principled way of reconstructing neural activity with high temporal resolution. However, measuring the brain’s location is compromised by head movement during scanning, and by fiducial-based co-registration with magnetic resonance imaging (MRI) data. The uncertainty from these two factors introduces errors into the forward model and limit the spatial resolution of the data. NEW METHOD: We present a method for stabilizing and reliably repositioning the head during scanning, and for co-registering MRI and MEG data with low error. RESULTS: Using this new flexible and comfortable subject-specific head-cast prototype, we find within-session movements of <0.25 mm and between-session repositioning errors around 1 mm. COMPARISON WITH EXISTING METHOD(S): This method is an improvement over existing methods for stabilizing the head or correcting for location shifts on- or off-line, which still introduce approximately 5 mm of uncertainty at best (Adjamian et al., 2004; Stolk et al., 2013; Whalen et al., 2008). Further, the head-cast design presented here is more comfortable, safer, and easier to use than the earlier 3D printed prototype, and give slightly lower co-registration errors (Troebinger et al., 2014b). CONCLUSIONS: We provide an empirical example of how these head-casts impact on source level reproducibility. Employment of the individual flexible head-casts for MEG recordings provide a reliable method of safely stabilizing the head during MEG recordings, and for co-registering MRI anatomical images to MEG functional data.