Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography

Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a ne...

Descripción completa

Detalles Bibliográficos
Autores principales: Aquila, Iolanda, Fernández-Golfín, Covadonga, Rincon, Luis Miguel, González, Ariana, García Martín, Ana, Hinojar, Rocio, Jimenez Nacher, Jose Julio, Indolfi, Ciro, Zamorano, Jose Luis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5265986/
https://www.ncbi.nlm.nih.gov/pubmed/27930514
http://dx.doi.org/10.1097/MD.0000000000005387
_version_ 1782500381163520000
author Aquila, Iolanda
Fernández-Golfín, Covadonga
Rincon, Luis Miguel
González, Ariana
García Martín, Ana
Hinojar, Rocio
Jimenez Nacher, Jose Julio
Indolfi, Ciro
Zamorano, Jose Luis
author_facet Aquila, Iolanda
Fernández-Golfín, Covadonga
Rincon, Luis Miguel
González, Ariana
García Martín, Ana
Hinojar, Rocio
Jimenez Nacher, Jose Julio
Indolfi, Ciro
Zamorano, Jose Luis
author_sort Aquila, Iolanda
collection PubMed
description Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a new fully automatic software to characterize MV anatomy in different forms of mitral regurgitation (MR) by 3D TEE. Sixty patients were included: 45 with more than moderate MR (28 organic MR [OMR] and 17 functional MR [FMR]) and 15 controls. All patients underwent TEE. 3D MV images obtained using 3D zoom were imported into the new software for automatic analysis. Different MV parameters were obtained and compared. Anatomic and dynamic differences between FMR and OMR were detected. A significant increase in systolic (859.75 vs 801.83 vs 607.78 mm(2); P = 0.002) and diastolic (1040.60 vs. 1217.83 and 859.74 mm(2); P < 0.001) annular sizes was observed in both OMR and FMR compared to that in controls. FMR had a reduced mitral annular contraction compared to degenerative cases of OMR and to controls (17.14% vs 32.78% and 29.89%; P = 0.007). Good reproducibility was demonstrated along with a short analysis time (mean 4.30 minutes). Annular characteristics and dynamics are abnormal in both FMR and OMR. Full 3D software analysis automatically calculates several significant parameters that provide a correct and complete assessment of anatomy and dynamic mitral annulus geometry and displacement in the 3D space. This analysis allows a better characterization of MR pathophysiology and could be useful in designing new devices for MR repair or replacement.
format Online
Article
Text
id pubmed-5265986
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-52659862017-02-06 Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography Aquila, Iolanda Fernández-Golfín, Covadonga Rincon, Luis Miguel González, Ariana García Martín, Ana Hinojar, Rocio Jimenez Nacher, Jose Julio Indolfi, Ciro Zamorano, Jose Luis Medicine (Baltimore) 3400 Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a new fully automatic software to characterize MV anatomy in different forms of mitral regurgitation (MR) by 3D TEE. Sixty patients were included: 45 with more than moderate MR (28 organic MR [OMR] and 17 functional MR [FMR]) and 15 controls. All patients underwent TEE. 3D MV images obtained using 3D zoom were imported into the new software for automatic analysis. Different MV parameters were obtained and compared. Anatomic and dynamic differences between FMR and OMR were detected. A significant increase in systolic (859.75 vs 801.83 vs 607.78 mm(2); P = 0.002) and diastolic (1040.60 vs. 1217.83 and 859.74 mm(2); P < 0.001) annular sizes was observed in both OMR and FMR compared to that in controls. FMR had a reduced mitral annular contraction compared to degenerative cases of OMR and to controls (17.14% vs 32.78% and 29.89%; P = 0.007). Good reproducibility was demonstrated along with a short analysis time (mean 4.30 minutes). Annular characteristics and dynamics are abnormal in both FMR and OMR. Full 3D software analysis automatically calculates several significant parameters that provide a correct and complete assessment of anatomy and dynamic mitral annulus geometry and displacement in the 3D space. This analysis allows a better characterization of MR pathophysiology and could be useful in designing new devices for MR repair or replacement. Wolters Kluwer Health 2016-12-09 /pmc/articles/PMC5265986/ /pubmed/27930514 http://dx.doi.org/10.1097/MD.0000000000005387 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. http://creativecommons.org/licenses/by-nc-sa/4.0
spellingShingle 3400
Aquila, Iolanda
Fernández-Golfín, Covadonga
Rincon, Luis Miguel
González, Ariana
García Martín, Ana
Hinojar, Rocio
Jimenez Nacher, Jose Julio
Indolfi, Ciro
Zamorano, Jose Luis
Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
title Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
title_full Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
title_fullStr Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
title_full_unstemmed Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
title_short Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
title_sort fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
topic 3400
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5265986/
https://www.ncbi.nlm.nih.gov/pubmed/27930514
http://dx.doi.org/10.1097/MD.0000000000005387
work_keys_str_mv AT aquilaiolanda fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT fernandezgolfincovadonga fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT rinconluismiguel fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT gonzalezariana fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT garciamartinana fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT hinojarrocio fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT jimeneznacherjosejulio fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT indolficiro fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography
AT zamoranojoseluis fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography