Cargando…
Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography
Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a ne...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5265986/ https://www.ncbi.nlm.nih.gov/pubmed/27930514 http://dx.doi.org/10.1097/MD.0000000000005387 |
_version_ | 1782500381163520000 |
---|---|
author | Aquila, Iolanda Fernández-Golfín, Covadonga Rincon, Luis Miguel González, Ariana García Martín, Ana Hinojar, Rocio Jimenez Nacher, Jose Julio Indolfi, Ciro Zamorano, Jose Luis |
author_facet | Aquila, Iolanda Fernández-Golfín, Covadonga Rincon, Luis Miguel González, Ariana García Martín, Ana Hinojar, Rocio Jimenez Nacher, Jose Julio Indolfi, Ciro Zamorano, Jose Luis |
author_sort | Aquila, Iolanda |
collection | PubMed |
description | Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a new fully automatic software to characterize MV anatomy in different forms of mitral regurgitation (MR) by 3D TEE. Sixty patients were included: 45 with more than moderate MR (28 organic MR [OMR] and 17 functional MR [FMR]) and 15 controls. All patients underwent TEE. 3D MV images obtained using 3D zoom were imported into the new software for automatic analysis. Different MV parameters were obtained and compared. Anatomic and dynamic differences between FMR and OMR were detected. A significant increase in systolic (859.75 vs 801.83 vs 607.78 mm(2); P = 0.002) and diastolic (1040.60 vs. 1217.83 and 859.74 mm(2); P < 0.001) annular sizes was observed in both OMR and FMR compared to that in controls. FMR had a reduced mitral annular contraction compared to degenerative cases of OMR and to controls (17.14% vs 32.78% and 29.89%; P = 0.007). Good reproducibility was demonstrated along with a short analysis time (mean 4.30 minutes). Annular characteristics and dynamics are abnormal in both FMR and OMR. Full 3D software analysis automatically calculates several significant parameters that provide a correct and complete assessment of anatomy and dynamic mitral annulus geometry and displacement in the 3D space. This analysis allows a better characterization of MR pathophysiology and could be useful in designing new devices for MR repair or replacement. |
format | Online Article Text |
id | pubmed-5265986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-52659862017-02-06 Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography Aquila, Iolanda Fernández-Golfín, Covadonga Rincon, Luis Miguel González, Ariana García Martín, Ana Hinojar, Rocio Jimenez Nacher, Jose Julio Indolfi, Ciro Zamorano, Jose Luis Medicine (Baltimore) 3400 Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a new fully automatic software to characterize MV anatomy in different forms of mitral regurgitation (MR) by 3D TEE. Sixty patients were included: 45 with more than moderate MR (28 organic MR [OMR] and 17 functional MR [FMR]) and 15 controls. All patients underwent TEE. 3D MV images obtained using 3D zoom were imported into the new software for automatic analysis. Different MV parameters were obtained and compared. Anatomic and dynamic differences between FMR and OMR were detected. A significant increase in systolic (859.75 vs 801.83 vs 607.78 mm(2); P = 0.002) and diastolic (1040.60 vs. 1217.83 and 859.74 mm(2); P < 0.001) annular sizes was observed in both OMR and FMR compared to that in controls. FMR had a reduced mitral annular contraction compared to degenerative cases of OMR and to controls (17.14% vs 32.78% and 29.89%; P = 0.007). Good reproducibility was demonstrated along with a short analysis time (mean 4.30 minutes). Annular characteristics and dynamics are abnormal in both FMR and OMR. Full 3D software analysis automatically calculates several significant parameters that provide a correct and complete assessment of anatomy and dynamic mitral annulus geometry and displacement in the 3D space. This analysis allows a better characterization of MR pathophysiology and could be useful in designing new devices for MR repair or replacement. Wolters Kluwer Health 2016-12-09 /pmc/articles/PMC5265986/ /pubmed/27930514 http://dx.doi.org/10.1097/MD.0000000000005387 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. http://creativecommons.org/licenses/by-nc-sa/4.0 |
spellingShingle | 3400 Aquila, Iolanda Fernández-Golfín, Covadonga Rincon, Luis Miguel González, Ariana García Martín, Ana Hinojar, Rocio Jimenez Nacher, Jose Julio Indolfi, Ciro Zamorano, Jose Luis Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography |
title | Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography |
title_full | Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography |
title_fullStr | Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography |
title_full_unstemmed | Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography |
title_short | Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography |
title_sort | fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography |
topic | 3400 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5265986/ https://www.ncbi.nlm.nih.gov/pubmed/27930514 http://dx.doi.org/10.1097/MD.0000000000005387 |
work_keys_str_mv | AT aquilaiolanda fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT fernandezgolfincovadonga fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT rinconluismiguel fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT gonzalezariana fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT garciamartinana fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT hinojarrocio fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT jimeneznacherjosejulio fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT indolficiro fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography AT zamoranojoseluis fullyautomatedsoftwareformitralannulusevaluationinchronicmitralregurgitationby3dimensionaltransesophagealechocardiography |