Cargando…

Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models

We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to...

Descripción completa

Detalles Bibliográficos
Autores principales: Beard, Brian B, Kainz, Wolfgang
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC526755/
https://www.ncbi.nlm.nih.gov/pubmed/15482601
http://dx.doi.org/10.1186/1475-925X-3-34
_version_ 1782121941647228928
author Beard, Brian B
Kainz, Wolfgang
author_facet Beard, Brian B
Kainz, Wolfgang
author_sort Beard, Brian B
collection PubMed
description We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the results of computational RF dosimetry studies. We concluded studies were not comparable because of differences in definitions, models, and methodology. Therefore we propose a protocol, developed by an IEEE standards group, as an initial step in alleviating this problem. The protocol calls for a benchmark validation study comparing the SAM phantom to two anatomically correct models of the human head. It also establishes common definitions and reporting requirements that will increase the comparability of all computational RF dosimetry studies of the human head.
format Text
id pubmed-526755
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-5267552004-11-12 Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models Beard, Brian B Kainz, Wolfgang Biomed Eng Online Review We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the results of computational RF dosimetry studies. We concluded studies were not comparable because of differences in definitions, models, and methodology. Therefore we propose a protocol, developed by an IEEE standards group, as an initial step in alleviating this problem. The protocol calls for a benchmark validation study comparing the SAM phantom to two anatomically correct models of the human head. It also establishes common definitions and reporting requirements that will increase the comparability of all computational RF dosimetry studies of the human head. BioMed Central 2004-10-13 /pmc/articles/PMC526755/ /pubmed/15482601 http://dx.doi.org/10.1186/1475-925X-3-34 Text en Copyright © 2004 Beard and Kainz; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review
Beard, Brian B
Kainz, Wolfgang
Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models
title Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models
title_full Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models
title_fullStr Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models
title_full_unstemmed Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models
title_short Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models
title_sort review and standardization of cell phone exposure calculations using the sam phantom and anatomically correct head models
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC526755/
https://www.ncbi.nlm.nih.gov/pubmed/15482601
http://dx.doi.org/10.1186/1475-925X-3-34
work_keys_str_mv AT beardbrianb reviewandstandardizationofcellphoneexposurecalculationsusingthesamphantomandanatomicallycorrectheadmodels
AT kainzwolfgang reviewandstandardizationofcellphoneexposurecalculationsusingthesamphantomandanatomicallycorrectheadmodels