Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs

OBJECTIVE: The objective was to quantitatively evaluate the validity of ultrasonographic (US) muscle measurements as compared to the gold standard of computed tomography (CT) in the canine. DESIGN: This was a prospective study. POPULATION: Twenty-five, client-owned dogs scheduled for CT as part of a...

Descripción completa

Detalles Bibliográficos
Autores principales: Bullen, Lindsey E., Evola, Maria G., Griffith, Emily H., Seiler, Gabriela S., Saker, Korinn E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5270592/
https://www.ncbi.nlm.nih.gov/pubmed/28149695
http://dx.doi.org/10.7717/peerj.2926
_version_ 1782501198678458368
author Bullen, Lindsey E.
Evola, Maria G.
Griffith, Emily H.
Seiler, Gabriela S.
Saker, Korinn E.
author_facet Bullen, Lindsey E.
Evola, Maria G.
Griffith, Emily H.
Seiler, Gabriela S.
Saker, Korinn E.
author_sort Bullen, Lindsey E.
collection PubMed
description OBJECTIVE: The objective was to quantitatively evaluate the validity of ultrasonographic (US) muscle measurements as compared to the gold standard of computed tomography (CT) in the canine. DESIGN: This was a prospective study. POPULATION: Twenty-five, client-owned dogs scheduled for CT as part of a diagnostic work-up for the management of their primary disease process were included. MATERIALS AND METHODS: Specific appendicular (cubital flexors and extensors, coxofemoral flexors and extensors) and axial (temporalis, supraspinatus, infraspinatus, lumbar epaxials) muscle groups were selected for quantitative measure based on CT planning and patient position. Prior to CT scan, the skin over the muscle sites was shaved and marked with a permanent marker. Patient body position was determined based on the patient’s CT plan; positioning was consistent between CT and US imaging. To ensure identical imaging position for both CT and US measurements, radio-opaque fiducial markers were placed directly over the skin marks once the dog was positioned. Quantitative measurements (cm) for both lean muscle mass (LMM) and subcutaneous adipose (SQA) were recorded. Statistical comparisons between CT and US values were done separately for each site and type. RESULTS: Muscle groups and associated SQA measured by US and CT were not statistically different based on an adjusted p-value using Bonferroni’s correction (p < 0.0031). In addition, all LMM and SQA sites had good reliability and agreement (Cronbach’s α = 0.8 − 1.0) between the two metrics, excluding the coxofemoral extensor muscle group (Cronbach’s α = 0.73232). Linear regression analysis of muscle measures indicated close agreement (slope range 0.93–1.09) and minimal bias of variation (intercept range 0.05–0.11) between CT versus US modalities, with the exception of the coxofemoral extensor muscle. Similarly, SQA CT and US measures indicated close agreement with the slope range of 0.88–1.02 and minimal bias of variation with an intercept range of 0.021–0.098, excluding the cubital flexor and extensor groups. Additionally, the R(2) values for these remaining LMM and SQA sites are reported as >0.897 for LLM and >0.8289 for SQA. CONCLUSIONS: Ultrasound imaging of selected appendicular and axial muscle groups in dogs can provide comparable assessment of muscle thickness to the current gold standard, CT. In consideration of both statistical reliability to CT and cage-side accessibility, the temporalis, supraspinatus, infraspinatus, and lumbar epaxial LMM sites are considered the most useful targets for US LMM assessment in the canine. Our findings support the potential utility of US as a clinical tool in veterinary medicine to assess LMM status in patients. Additional studies are indicated to develop standardized protocols of its use in a cage-side setting and to elucidate the benefit of this modality, in conjunction with nutritional interventions, to manage body LLM stores in compromised patients.
format Online
Article
Text
id pubmed-5270592
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-52705922017-02-01 Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs Bullen, Lindsey E. Evola, Maria G. Griffith, Emily H. Seiler, Gabriela S. Saker, Korinn E. PeerJ Veterinary Medicine OBJECTIVE: The objective was to quantitatively evaluate the validity of ultrasonographic (US) muscle measurements as compared to the gold standard of computed tomography (CT) in the canine. DESIGN: This was a prospective study. POPULATION: Twenty-five, client-owned dogs scheduled for CT as part of a diagnostic work-up for the management of their primary disease process were included. MATERIALS AND METHODS: Specific appendicular (cubital flexors and extensors, coxofemoral flexors and extensors) and axial (temporalis, supraspinatus, infraspinatus, lumbar epaxials) muscle groups were selected for quantitative measure based on CT planning and patient position. Prior to CT scan, the skin over the muscle sites was shaved and marked with a permanent marker. Patient body position was determined based on the patient’s CT plan; positioning was consistent between CT and US imaging. To ensure identical imaging position for both CT and US measurements, radio-opaque fiducial markers were placed directly over the skin marks once the dog was positioned. Quantitative measurements (cm) for both lean muscle mass (LMM) and subcutaneous adipose (SQA) were recorded. Statistical comparisons between CT and US values were done separately for each site and type. RESULTS: Muscle groups and associated SQA measured by US and CT were not statistically different based on an adjusted p-value using Bonferroni’s correction (p < 0.0031). In addition, all LMM and SQA sites had good reliability and agreement (Cronbach’s α = 0.8 − 1.0) between the two metrics, excluding the coxofemoral extensor muscle group (Cronbach’s α = 0.73232). Linear regression analysis of muscle measures indicated close agreement (slope range 0.93–1.09) and minimal bias of variation (intercept range 0.05–0.11) between CT versus US modalities, with the exception of the coxofemoral extensor muscle. Similarly, SQA CT and US measures indicated close agreement with the slope range of 0.88–1.02 and minimal bias of variation with an intercept range of 0.021–0.098, excluding the cubital flexor and extensor groups. Additionally, the R(2) values for these remaining LMM and SQA sites are reported as >0.897 for LLM and >0.8289 for SQA. CONCLUSIONS: Ultrasound imaging of selected appendicular and axial muscle groups in dogs can provide comparable assessment of muscle thickness to the current gold standard, CT. In consideration of both statistical reliability to CT and cage-side accessibility, the temporalis, supraspinatus, infraspinatus, and lumbar epaxial LMM sites are considered the most useful targets for US LMM assessment in the canine. Our findings support the potential utility of US as a clinical tool in veterinary medicine to assess LMM status in patients. Additional studies are indicated to develop standardized protocols of its use in a cage-side setting and to elucidate the benefit of this modality, in conjunction with nutritional interventions, to manage body LLM stores in compromised patients. PeerJ Inc. 2017-01-25 /pmc/articles/PMC5270592/ /pubmed/28149695 http://dx.doi.org/10.7717/peerj.2926 Text en ©2017 Bullen et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Veterinary Medicine
Bullen, Lindsey E.
Evola, Maria G.
Griffith, Emily H.
Seiler, Gabriela S.
Saker, Korinn E.
Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
title Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
title_full Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
title_fullStr Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
title_full_unstemmed Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
title_short Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
title_sort validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
topic Veterinary Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5270592/
https://www.ncbi.nlm.nih.gov/pubmed/28149695
http://dx.doi.org/10.7717/peerj.2926
work_keys_str_mv AT bullenlindseye validationofultrasonographicmusclethicknessmeasurementsascomparedtothegoldstandardofcomputedtomographyindogs
AT evolamariag validationofultrasonographicmusclethicknessmeasurementsascomparedtothegoldstandardofcomputedtomographyindogs
AT griffithemilyh validationofultrasonographicmusclethicknessmeasurementsascomparedtothegoldstandardofcomputedtomographyindogs
AT seilergabrielas validationofultrasonographicmusclethicknessmeasurementsascomparedtothegoldstandardofcomputedtomographyindogs
AT sakerkorinne validationofultrasonographicmusclethicknessmeasurementsascomparedtothegoldstandardofcomputedtomographyindogs