Cargando…
Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films
The surface area of electrodeposited thin films of Ni, Co, and NiCo was evaluated using electrochemical double-layer capacitance, electrochemical area measurements using the [Ru(NH[Formula: see text] )[Formula: see text] ][Formula: see text] /[Ru(NH[Formula: see text] )[Formula: see text] ][Formula:...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korea Nano Technology Research Society
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5271141/ https://www.ncbi.nlm.nih.gov/pubmed/28191416 http://dx.doi.org/10.1186/s40580-016-0063-0 |
_version_ | 1782501296475996160 |
---|---|
author | Gira, Matthew J. Tkacz, Kevin P. Hampton, Jennifer R. |
author_facet | Gira, Matthew J. Tkacz, Kevin P. Hampton, Jennifer R. |
author_sort | Gira, Matthew J. |
collection | PubMed |
description | The surface area of electrodeposited thin films of Ni, Co, and NiCo was evaluated using electrochemical double-layer capacitance, electrochemical area measurements using the [Ru(NH[Formula: see text] )[Formula: see text] ][Formula: see text] /[Ru(NH[Formula: see text] )[Formula: see text] ][Formula: see text] redox couple, and topographic atomic force microscopy (AFM) imaging. These three methods were compared to each other for each composition separately and for the entire set of samples regardless of composition. Double-layer capacitance measurements were found to be positively correlated to the roughness factors determined by AFM topography. Electrochemical area measurements were found to be less correlated with measured roughness factors as well as applicable only to two of the three compositions studied. The results indicate that in situ double-layer capacitance measurements are a practical, versatile technique for estimating the accessible surface area of a metal sample. |
format | Online Article Text |
id | pubmed-5271141 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korea Nano Technology Research Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-52711412017-02-09 Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films Gira, Matthew J. Tkacz, Kevin P. Hampton, Jennifer R. Nano Converg Research The surface area of electrodeposited thin films of Ni, Co, and NiCo was evaluated using electrochemical double-layer capacitance, electrochemical area measurements using the [Ru(NH[Formula: see text] )[Formula: see text] ][Formula: see text] /[Ru(NH[Formula: see text] )[Formula: see text] ][Formula: see text] redox couple, and topographic atomic force microscopy (AFM) imaging. These three methods were compared to each other for each composition separately and for the entire set of samples regardless of composition. Double-layer capacitance measurements were found to be positively correlated to the roughness factors determined by AFM topography. Electrochemical area measurements were found to be less correlated with measured roughness factors as well as applicable only to two of the three compositions studied. The results indicate that in situ double-layer capacitance measurements are a practical, versatile technique for estimating the accessible surface area of a metal sample. Korea Nano Technology Research Society 2016-01-29 /pmc/articles/PMC5271141/ /pubmed/28191416 http://dx.doi.org/10.1186/s40580-016-0063-0 Text en © Gira et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Gira, Matthew J. Tkacz, Kevin P. Hampton, Jennifer R. Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films |
title | Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films |
title_full | Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films |
title_fullStr | Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films |
title_full_unstemmed | Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films |
title_short | Physical and electrochemical area determination of electrodeposited Ni, Co, and NiCo thin films |
title_sort | physical and electrochemical area determination of electrodeposited ni, co, and nico thin films |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5271141/ https://www.ncbi.nlm.nih.gov/pubmed/28191416 http://dx.doi.org/10.1186/s40580-016-0063-0 |
work_keys_str_mv | AT giramatthewj physicalandelectrochemicalareadeterminationofelectrodepositednicoandnicothinfilms AT tkaczkevinp physicalandelectrochemicalareadeterminationofelectrodepositednicoandnicothinfilms AT hamptonjenniferr physicalandelectrochemicalareadeterminationofelectrodepositednicoandnicothinfilms |