Cargando…

Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction

BACKGROUND: Accurate assessment of myocardium at risk (MaR) after acute myocardial infarction (AMI) is necessary when assessing myocardial salvage. Contrast-enhanced steady-state free precession (CE-SSFP) is a recently developed cardiovascular magnetic resonance (CMR) method for assessment of MaR up...

Descripción completa

Detalles Bibliográficos
Autores principales: Nordlund, David, Kanski, Mikael, Jablonowski, Robert, Koul, Sasha, Erlinge, David, Carlsson, Marcus, Engblom, Henrik, Aletras, Anthony H., Arheden, Håkan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5278574/
https://www.ncbi.nlm.nih.gov/pubmed/28132648
http://dx.doi.org/10.1186/s12968-017-0325-y
_version_ 1782502665208463360
author Nordlund, David
Kanski, Mikael
Jablonowski, Robert
Koul, Sasha
Erlinge, David
Carlsson, Marcus
Engblom, Henrik
Aletras, Anthony H.
Arheden, Håkan
author_facet Nordlund, David
Kanski, Mikael
Jablonowski, Robert
Koul, Sasha
Erlinge, David
Carlsson, Marcus
Engblom, Henrik
Aletras, Anthony H.
Arheden, Håkan
author_sort Nordlund, David
collection PubMed
description BACKGROUND: Accurate assessment of myocardium at risk (MaR) after acute myocardial infarction (AMI) is necessary when assessing myocardial salvage. Contrast-enhanced steady-state free precession (CE-SSFP) is a recently developed cardiovascular magnetic resonance (CMR) method for assessment of MaR up to 1 week after AMI. Our aim was to validate CE-SSFP for determination of MaR in an experimental porcine model using myocardial perfusion single-photon emission computed tomography (MPS) as a reference standard and to test the stability of MaR-quantification over time after injecting gadolinium-based contrast. METHODS: Eleven pigs were subjected to either 35 or 40 min occlusion of the left anterior descending artery followed by six hours of reperfusion. A technetium-based perfusion tracer was administered intravenously ten minutes before reperfusion. In-vivo and ex-vivo CE-SSFP CMR was performed followed by ex-vivo MPS imaging. MaR was expressed as % of left ventricular mass (LVM). RESULTS: There was good agreement between MaR by ex-vivo CMR and MaR by MPS (bias: 1 ± 3% LVM, r (2) = 0.92, p < 0.001), between ex-vivo and in-vivo CMR (bias 0 ± 2% LVM, r (2) = 0.94, p < 0.001) and between in-vivo CMR and MPS (bias -2 ± 3% LVM, r (2) = 0.87, p < 0.001. No change in MaR was seen over the first 30 min after contrast injection (p = 0.95). CONCLUSIONS: Contrast-enhanced SSFP cine CMR can be used to measure MaR, both in vivo and ex vivo, in a porcine model with good accuracy and precision over the first 30 min after contrast injection. This offers the option to use the less complex ex-vivo imaging when determining myocardial salvage in experimental studies.
format Online
Article
Text
id pubmed-5278574
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-52785742017-02-03 Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction Nordlund, David Kanski, Mikael Jablonowski, Robert Koul, Sasha Erlinge, David Carlsson, Marcus Engblom, Henrik Aletras, Anthony H. Arheden, Håkan J Cardiovasc Magn Reson Research BACKGROUND: Accurate assessment of myocardium at risk (MaR) after acute myocardial infarction (AMI) is necessary when assessing myocardial salvage. Contrast-enhanced steady-state free precession (CE-SSFP) is a recently developed cardiovascular magnetic resonance (CMR) method for assessment of MaR up to 1 week after AMI. Our aim was to validate CE-SSFP for determination of MaR in an experimental porcine model using myocardial perfusion single-photon emission computed tomography (MPS) as a reference standard and to test the stability of MaR-quantification over time after injecting gadolinium-based contrast. METHODS: Eleven pigs were subjected to either 35 or 40 min occlusion of the left anterior descending artery followed by six hours of reperfusion. A technetium-based perfusion tracer was administered intravenously ten minutes before reperfusion. In-vivo and ex-vivo CE-SSFP CMR was performed followed by ex-vivo MPS imaging. MaR was expressed as % of left ventricular mass (LVM). RESULTS: There was good agreement between MaR by ex-vivo CMR and MaR by MPS (bias: 1 ± 3% LVM, r (2) = 0.92, p < 0.001), between ex-vivo and in-vivo CMR (bias 0 ± 2% LVM, r (2) = 0.94, p < 0.001) and between in-vivo CMR and MPS (bias -2 ± 3% LVM, r (2) = 0.87, p < 0.001. No change in MaR was seen over the first 30 min after contrast injection (p = 0.95). CONCLUSIONS: Contrast-enhanced SSFP cine CMR can be used to measure MaR, both in vivo and ex vivo, in a porcine model with good accuracy and precision over the first 30 min after contrast injection. This offers the option to use the less complex ex-vivo imaging when determining myocardial salvage in experimental studies. BioMed Central 2017-01-30 /pmc/articles/PMC5278574/ /pubmed/28132648 http://dx.doi.org/10.1186/s12968-017-0325-y Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Nordlund, David
Kanski, Mikael
Jablonowski, Robert
Koul, Sasha
Erlinge, David
Carlsson, Marcus
Engblom, Henrik
Aletras, Anthony H.
Arheden, Håkan
Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
title Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
title_full Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
title_fullStr Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
title_full_unstemmed Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
title_short Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
title_sort experimental validation of contrast-enhanced ssfp cine cmr for quantification of myocardium at risk in acute myocardial infarction
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5278574/
https://www.ncbi.nlm.nih.gov/pubmed/28132648
http://dx.doi.org/10.1186/s12968-017-0325-y
work_keys_str_mv AT nordlunddavid experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT kanskimikael experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT jablonowskirobert experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT koulsasha experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT erlingedavid experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT carlssonmarcus experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT engblomhenrik experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT aletrasanthonyh experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction
AT arhedenhakan experimentalvalidationofcontrastenhancedssfpcinecmrforquantificationofmyocardiumatriskinacutemyocardialinfarction