Cargando…
Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
INTRODUCTION: The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS: A total of 27 Wistar rats were used. Four polyethylene tubes w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5282382/ https://www.ncbi.nlm.nih.gov/pubmed/28179927 http://dx.doi.org/10.22037/iej.2017.13 |
_version_ | 1782503308862160896 |
---|---|
author | Omidi, Salma Javidi, Maryam Zarei, Mina Mushakhian, Siavash Jafarian, Amirhossein |
author_facet | Omidi, Salma Javidi, Maryam Zarei, Mina Mushakhian, Siavash Jafarian, Amirhossein |
author_sort | Omidi, Salma |
collection | PubMed |
description | INTRODUCTION: The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS: A total of 27 Wistar rats were used. Four polyethylene tubes were implanted in the back of each rat (three tubes containing the test materials and an empty tube as a control). Then, 9 animals were sacrificed at each interval of 15, 30 and 60 days, and the implants were removed with the surrounding tissues.Samples were evaluated for the presence of inflammatory cell (mononuclear cell), vascular changes, fibrous tissue formation and present of giant cell. Comparisons between groups and time-periods were performed using the Kruskal-Wallis and Mann-Whitney U non-parametric tests. The level of significance was set at 0.05. RESULTS: No significant difference was observed in tissue reactions and biocompatibility pattern of three sealers during 3 experimental periods (P<0.05). In all groups the tissue behavior showed tendency to decrease the irritation effect over time. Conclusion: The new nano zinc-oxide eugenol sealer has histocompatibility properties comparable to conventional commercial sealers. |
format | Online Article Text |
id | pubmed-5282382 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-52823822017-02-08 Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model Omidi, Salma Javidi, Maryam Zarei, Mina Mushakhian, Siavash Jafarian, Amirhossein Iran Endod J Original Article INTRODUCTION: The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS: A total of 27 Wistar rats were used. Four polyethylene tubes were implanted in the back of each rat (three tubes containing the test materials and an empty tube as a control). Then, 9 animals were sacrificed at each interval of 15, 30 and 60 days, and the implants were removed with the surrounding tissues.Samples were evaluated for the presence of inflammatory cell (mononuclear cell), vascular changes, fibrous tissue formation and present of giant cell. Comparisons between groups and time-periods were performed using the Kruskal-Wallis and Mann-Whitney U non-parametric tests. The level of significance was set at 0.05. RESULTS: No significant difference was observed in tissue reactions and biocompatibility pattern of three sealers during 3 experimental periods (P<0.05). In all groups the tissue behavior showed tendency to decrease the irritation effect over time. Conclusion: The new nano zinc-oxide eugenol sealer has histocompatibility properties comparable to conventional commercial sealers. Iranian Center for Endodontic Research 2017 /pmc/articles/PMC5282382/ /pubmed/28179927 http://dx.doi.org/10.22037/iej.2017.13 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Omidi, Salma Javidi, Maryam Zarei, Mina Mushakhian, Siavash Jafarian, Amirhossein Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model |
title | Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model |
title_full | Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model |
title_fullStr | Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model |
title_full_unstemmed | Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model |
title_short | Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model |
title_sort | subcutaneous connective tissue reaction to a new nano zinc-oxide eugenol sealer in rat model |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5282382/ https://www.ncbi.nlm.nih.gov/pubmed/28179927 http://dx.doi.org/10.22037/iej.2017.13 |
work_keys_str_mv | AT omidisalma subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel AT javidimaryam subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel AT zareimina subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel AT mushakhiansiavash subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel AT jafarianamirhossein subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel |