Cargando…

Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model

INTRODUCTION: The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS: A total of 27 Wistar rats were used. Four polyethylene tubes w...

Descripción completa

Detalles Bibliográficos
Autores principales: Omidi, Salma, Javidi, Maryam, Zarei, Mina, Mushakhian, Siavash, Jafarian, Amirhossein
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iranian Center for Endodontic Research 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5282382/
https://www.ncbi.nlm.nih.gov/pubmed/28179927
http://dx.doi.org/10.22037/iej.2017.13
_version_ 1782503308862160896
author Omidi, Salma
Javidi, Maryam
Zarei, Mina
Mushakhian, Siavash
Jafarian, Amirhossein
author_facet Omidi, Salma
Javidi, Maryam
Zarei, Mina
Mushakhian, Siavash
Jafarian, Amirhossein
author_sort Omidi, Salma
collection PubMed
description INTRODUCTION: The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS: A total of 27 Wistar rats were used. Four polyethylene tubes were implanted in the back of each rat (three tubes containing the test materials and an empty tube as a control). Then, 9 animals were sacrificed at each interval of 15, 30 and 60 days, and the implants were removed with the surrounding tissues.Samples were evaluated for the presence of inflammatory cell (mononuclear cell), vascular changes, fibrous tissue formation and present of giant cell. Comparisons between groups and time-periods were performed using the Kruskal-Wallis and Mann-Whitney U non-parametric tests. The level of significance was set at 0.05. RESULTS: No significant difference was observed in tissue reactions and biocompatibility pattern of three sealers during 3 experimental periods (P<0.05). In all groups the tissue behavior showed tendency to decrease the irritation effect over time. Conclusion: The new nano zinc-oxide eugenol sealer has histocompatibility properties comparable to conventional commercial sealers.
format Online
Article
Text
id pubmed-5282382
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Iranian Center for Endodontic Research
record_format MEDLINE/PubMed
spelling pubmed-52823822017-02-08 Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model Omidi, Salma Javidi, Maryam Zarei, Mina Mushakhian, Siavash Jafarian, Amirhossein Iran Endod J Original Article INTRODUCTION: The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS: A total of 27 Wistar rats were used. Four polyethylene tubes were implanted in the back of each rat (three tubes containing the test materials and an empty tube as a control). Then, 9 animals were sacrificed at each interval of 15, 30 and 60 days, and the implants were removed with the surrounding tissues.Samples were evaluated for the presence of inflammatory cell (mononuclear cell), vascular changes, fibrous tissue formation and present of giant cell. Comparisons between groups and time-periods were performed using the Kruskal-Wallis and Mann-Whitney U non-parametric tests. The level of significance was set at 0.05. RESULTS: No significant difference was observed in tissue reactions and biocompatibility pattern of three sealers during 3 experimental periods (P<0.05). In all groups the tissue behavior showed tendency to decrease the irritation effect over time. Conclusion: The new nano zinc-oxide eugenol sealer has histocompatibility properties comparable to conventional commercial sealers. Iranian Center for Endodontic Research 2017 /pmc/articles/PMC5282382/ /pubmed/28179927 http://dx.doi.org/10.22037/iej.2017.13 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Omidi, Salma
Javidi, Maryam
Zarei, Mina
Mushakhian, Siavash
Jafarian, Amirhossein
Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
title Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
title_full Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
title_fullStr Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
title_full_unstemmed Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
title_short Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
title_sort subcutaneous connective tissue reaction to a new nano zinc-oxide eugenol sealer in rat model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5282382/
https://www.ncbi.nlm.nih.gov/pubmed/28179927
http://dx.doi.org/10.22037/iej.2017.13
work_keys_str_mv AT omidisalma subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel
AT javidimaryam subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel
AT zareimina subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel
AT mushakhiansiavash subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel
AT jafarianamirhossein subcutaneousconnectivetissuereactiontoanewnanozincoxideeugenolsealerinratmodel