Cargando…
Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia
OBJECTIVES: To compare retinal and optic disc characteristics between amblyopic and non-amblyopic eyes in patients with myopic and hyperopic anisometropia measured with optical coherence tomography (OCT). MATERIALS AND METHODS: Patients with myopic (25 patients: 17 female, 8 male; median age 27 year...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Galenos Publishing
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5282538/ https://www.ncbi.nlm.nih.gov/pubmed/28182148 http://dx.doi.org/10.4274/tjo.54289 |
_version_ | 1782503341409959936 |
---|---|
author | Taşkıran Çömez, Arzu Şanal Ulu, Elif Ekim, Yeliz |
author_facet | Taşkıran Çömez, Arzu Şanal Ulu, Elif Ekim, Yeliz |
author_sort | Taşkıran Çömez, Arzu |
collection | PubMed |
description | OBJECTIVES: To compare retinal and optic disc characteristics between amblyopic and non-amblyopic eyes in patients with myopic and hyperopic anisometropia measured with optical coherence tomography (OCT). MATERIALS AND METHODS: Patients with myopic (25 patients: 17 female, 8 male; median age 27 years, range 16-40 years) and hyperopic (31 patients: 19 female, 12 male; median age 20 years, range 13-41 years) anisometropic amblyopia were included. Eye examination included determination of best-corrected visual acuity (BCVA) with a Snellen chart, measurement of manifest and cycloplegic refraction after pupillary dilation, alternate cover testing, globe movement evaluation, A-scan biometry for axial length, biomicroscopy, fundus examination, and OCT scanning. Main outcome measures were spherical equivalence, BCVA, axial length, retinal nerve fiber layer (RNFL) thickness, macular thickness, macular volume, and optic disc area. RESULTS: In both myopic and hyperopic patients, the absolute value of the mean spherical equivalence was significantly greater in the amblyopic than non-amblyopic eyes, and the mean BCVA was significantly less in the amblyopic than the non-amblyopic eyes. In both myopic and hyperopic patients, there were no significant differences in mean RNFL thickness, macular thickness, macular volume, axial length, or optic disc area between amblyopic and non-amblyopic eyes. CONCLUSION: The amblyopic process may have no significant effect on the RNFL, macula, or optic disc. Further studies with more patients, including postmortem studies, may clarify the retinal, histopathologic, and anatomic differences between amblyopic and non-amblyopic eyes. |
format | Online Article Text |
id | pubmed-5282538 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Galenos Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-52825382017-02-08 Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia Taşkıran Çömez, Arzu Şanal Ulu, Elif Ekim, Yeliz Turk J Ophthalmol Original Article OBJECTIVES: To compare retinal and optic disc characteristics between amblyopic and non-amblyopic eyes in patients with myopic and hyperopic anisometropia measured with optical coherence tomography (OCT). MATERIALS AND METHODS: Patients with myopic (25 patients: 17 female, 8 male; median age 27 years, range 16-40 years) and hyperopic (31 patients: 19 female, 12 male; median age 20 years, range 13-41 years) anisometropic amblyopia were included. Eye examination included determination of best-corrected visual acuity (BCVA) with a Snellen chart, measurement of manifest and cycloplegic refraction after pupillary dilation, alternate cover testing, globe movement evaluation, A-scan biometry for axial length, biomicroscopy, fundus examination, and OCT scanning. Main outcome measures were spherical equivalence, BCVA, axial length, retinal nerve fiber layer (RNFL) thickness, macular thickness, macular volume, and optic disc area. RESULTS: In both myopic and hyperopic patients, the absolute value of the mean spherical equivalence was significantly greater in the amblyopic than non-amblyopic eyes, and the mean BCVA was significantly less in the amblyopic than the non-amblyopic eyes. In both myopic and hyperopic patients, there were no significant differences in mean RNFL thickness, macular thickness, macular volume, axial length, or optic disc area between amblyopic and non-amblyopic eyes. CONCLUSION: The amblyopic process may have no significant effect on the RNFL, macula, or optic disc. Further studies with more patients, including postmortem studies, may clarify the retinal, histopathologic, and anatomic differences between amblyopic and non-amblyopic eyes. Galenos Publishing 2017-01 2017-01-17 /pmc/articles/PMC5282538/ /pubmed/28182148 http://dx.doi.org/10.4274/tjo.54289 Text en © Copyright 2017 by Turkish Ophthalmological Association Turkish Journal of Ophthalmology, published by Galenos Publishing House. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Taşkıran Çömez, Arzu Şanal Ulu, Elif Ekim, Yeliz Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia |
title | Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia |
title_full | Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia |
title_fullStr | Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia |
title_full_unstemmed | Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia |
title_short | Retina and Optic Disc Characteristics in Amblyopic and Non-amblyopic Eyes of Patients with Myopic or Hyperopic Anisometropia |
title_sort | retina and optic disc characteristics in amblyopic and non-amblyopic eyes of patients with myopic or hyperopic anisometropia |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5282538/ https://www.ncbi.nlm.nih.gov/pubmed/28182148 http://dx.doi.org/10.4274/tjo.54289 |
work_keys_str_mv | AT taskırancomezarzu retinaandopticdisccharacteristicsinamblyopicandnonamblyopiceyesofpatientswithmyopicorhyperopicanisometropia AT sanaluluelif retinaandopticdisccharacteristicsinamblyopicandnonamblyopiceyesofpatientswithmyopicorhyperopicanisometropia AT ekimyeliz retinaandopticdisccharacteristicsinamblyopicandnonamblyopiceyesofpatientswithmyopicorhyperopicanisometropia |