Cargando…

Central venous access related adverse events after trabectedin infusions in soft tissue sarcoma patients; experience and management in a nationwide multi-center study

BACKGROUND: Trabectedin has shown efficacy against soft tissue sarcomas (STS) and has manageable toxicity. Trabectedin is administered through central venous access devices (VAD), such as subcutaneous ports with tunneled catheters, Hickman catheters and PICC lines. Venous access related adverse even...

Descripción completa

Detalles Bibliográficos
Autores principales: Verboom, Michiel C., Ouwerkerk, Jan, Steeghs, Neeltje, Lutjeboer, Jacob, Martijn Kerst, J., van der Graaf, Winette T. A., Reyners, Anna K. L., Sleijfer, Stefan, Gelderblom, Hans
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5282803/
https://www.ncbi.nlm.nih.gov/pubmed/28163887
http://dx.doi.org/10.1186/s13569-017-0066-6
Descripción
Sumario:BACKGROUND: Trabectedin has shown efficacy against soft tissue sarcomas (STS) and has manageable toxicity. Trabectedin is administered through central venous access devices (VAD), such as subcutaneous ports with tunneled catheters, Hickman catheters and PICC lines. Venous access related adverse events are common, but have not yet been reported in detail. METHODS: A retrospective analysis of patient files of STS patients receiving trabectedin monotherapy between 1999 and 2014 was performed in all five STS referral centers in the Netherlands. This survey focused on adverse events related to the VAD and the actions taken in response to these events. RESULTS: In the 127 patients included in this analysis, 102 venous access ports (VAP), 15 Hickman catheters and 10 PICC lines were used as primary means of central venous access. The most frequently reported adverse events at the VAD site were erythema (30.7%), pain (28.3%), inflammation (11.8%) and thrombosis (11.0%). Actions taken towards these adverse events include oral antibiotics (17.3%), VAD replacement (15.0%) or a wait-and-see policy (13.4%). In total, 45 patients (35.4%) with a subcutaneous port developed a varying degree of inflammation along the trajectory of the tunneled catheter. In all but three patients, this was a sterile inflammation, which was considered a unique phenomenon for trabectedin. Microscopic leakage of trabectedin along the venous access device and catheter was considered the most plausible cause for this adverse event. Placing the catheter deeper under the skin resolved the issue almost completely. CONCLUSION: Trabectedin infusion commonly leads to central venous access related adverse events. Sterile inflammation along the catheter trajectory is one of the most common adverse events and can be prevented by placing the catheter deeper under the skin.