Pseudothrombocytopenia with multiple anticoagulant sample collection tubes

The knowledge of pseudothrombocytopenia (PTCP) is important for the accuracy of a clinical assessment and for avoiding unnecessary treatment. An elderly patient was hospitalized with left lung pneumonia. Severe thrombocytopenia [platelet (PLT) number: 18 × 10(9)/L] without any clinical bleeding was...

Descripción completa

Detalles Bibliográficos
Autores principales: Kovacs, Ferenc, Varga, Marina, Pataki, Zsolt, Rigo, Erzsebet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Akadémiai Kiadó 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5283778/
https://www.ncbi.nlm.nih.gov/pubmed/28180009
http://dx.doi.org/10.1556/1646.8.2016.4.4
Descripción
Sumario:The knowledge of pseudothrombocytopenia (PTCP) is important for the accuracy of a clinical assessment and for avoiding unnecessary treatment. An elderly patient was hospitalized with left lung pneumonia. Severe thrombocytopenia [platelet (PLT) number: 18 × 10(9)/L] without any clinical bleeding was found in ethylenediaminetetraacetic acid blood collection tube. PLT measurement was repeated in various anticoagulant [sodium citrate, lithium heparin, disodium oxalate, hirudin, and magnesium sulfate (Mg-sulfate)] sample collection tubes and all of them showed thrombocytopenia except with Mg-sulfate. To the best of our knowledge, PTCP with five anticoagulant sample collection tubes has not been reported earlier.