Cargando…
Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments
The energy dependence of the cross section, σ(E), for the symmetric (resonant) charge transfer reaction Ar(+)(Ar,Ar)Ar(+) was measured in our triple quadrupole (QQQ) tandem mass spectrometer. Our σ(E), for P≃0.04–0.43 mtorr and E≃5 – 60 eV (LAB) [the range of collision energies used for collisionall...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1987
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5286968/ http://dx.doi.org/10.6028/jres.092.019 |
_version_ | 1782504085169111040 |
---|---|
author | Martinez, Richard I. Dheandhanoo, Seksan |
author_facet | Martinez, Richard I. Dheandhanoo, Seksan |
author_sort | Martinez, Richard I. |
collection | PubMed |
description | The energy dependence of the cross section, σ(E), for the symmetric (resonant) charge transfer reaction Ar(+)(Ar,Ar)Ar(+) was measured in our triple quadrupole (QQQ) tandem mass spectrometer. Our σ(E), for P≃0.04–0.43 mtorr and E≃5 – 60 eV (LAB) [the range of collision energies used for collisionally activated dissociation (CAD)], agrees to within 10% with the Rapp-Francis theory (impact parameter method in the two-state approximation), as corrected by Dewangan. We measured identical σ(E) from both the rate of reactant ion decay and the rate of product ion formation; i.e., our instrument is kinetically well behaved. The measurement of these σ(E) in other QQQ instruments can be used to validate whether or not a QQQ instrument has been properly designed to be kinetically well behaved. This is essential if generic, instrument-independent CAD spectral databases are to be developed on the basis of the absolute cross sections for the CAD of known ionic substructures. That is, since tandem mass spectrometry (MS/MS) exploits the ion fragmentation patterns characteristic of ionic substructures, the characteristic profiles [“breakdown curves”] of ion abundance versus target thickness (or collision energy) correspond uniquely to the sequence: (parent)(i) [Formula: see text] (daughter), [Formula: see text] (granddaughter)(k), etc. Hence, computer simulation of experimentally observed breakdown curves enables the structure of an unknown species to be assigned on the basis of the absolute cross sections σ(ij), σ(jk), etc. for CAD of known ionic substructures i, j, k, etc. Thus, if the calculated and experimental breakdown curves agree, the structure would be characterized. |
format | Online Article Text |
id | pubmed-5286968 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1987 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-52869682021-08-02 Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments Martinez, Richard I. Dheandhanoo, Seksan J Res Natl Bur Stand (1977) Article The energy dependence of the cross section, σ(E), for the symmetric (resonant) charge transfer reaction Ar(+)(Ar,Ar)Ar(+) was measured in our triple quadrupole (QQQ) tandem mass spectrometer. Our σ(E), for P≃0.04–0.43 mtorr and E≃5 – 60 eV (LAB) [the range of collision energies used for collisionally activated dissociation (CAD)], agrees to within 10% with the Rapp-Francis theory (impact parameter method in the two-state approximation), as corrected by Dewangan. We measured identical σ(E) from both the rate of reactant ion decay and the rate of product ion formation; i.e., our instrument is kinetically well behaved. The measurement of these σ(E) in other QQQ instruments can be used to validate whether or not a QQQ instrument has been properly designed to be kinetically well behaved. This is essential if generic, instrument-independent CAD spectral databases are to be developed on the basis of the absolute cross sections for the CAD of known ionic substructures. That is, since tandem mass spectrometry (MS/MS) exploits the ion fragmentation patterns characteristic of ionic substructures, the characteristic profiles [“breakdown curves”] of ion abundance versus target thickness (or collision energy) correspond uniquely to the sequence: (parent)(i) [Formula: see text] (daughter), [Formula: see text] (granddaughter)(k), etc. Hence, computer simulation of experimentally observed breakdown curves enables the structure of an unknown species to be assigned on the basis of the absolute cross sections σ(ij), σ(jk), etc. for CAD of known ionic substructures i, j, k, etc. Thus, if the calculated and experimental breakdown curves agree, the structure would be characterized. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1987 1987-06-01 /pmc/articles/PMC5286968/ http://dx.doi.org/10.6028/jres.092.019 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Bureau of Standards is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Martinez, Richard I. Dheandhanoo, Seksan Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments |
title | Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments |
title_full | Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments |
title_fullStr | Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments |
title_full_unstemmed | Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments |
title_short | Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments |
title_sort | instrument-independent cad spectral databases: absolute cross-section measurements in qqq instruments |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5286968/ http://dx.doi.org/10.6028/jres.092.019 |
work_keys_str_mv | AT martinezrichardi instrumentindependentcadspectraldatabasesabsolutecrosssectionmeasurementsinqqqinstruments AT dheandhanooseksan instrumentindependentcadspectraldatabasesabsolutecrosssectionmeasurementsinqqqinstruments |