Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments

The energy dependence of the cross section, σ(E), for the symmetric (resonant) charge transfer reaction Ar(+)(Ar,Ar)Ar(+) was measured in our triple quadrupole (QQQ) tandem mass spectrometer. Our σ(E), for P≃0.04–0.43 mtorr and E≃5 – 60 eV (LAB) [the range of collision energies used for collisionall...

Descripción completa

Detalles Bibliográficos
Autores principales: Martinez, Richard I., Dheandhanoo, Seksan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1987
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5286968/
http://dx.doi.org/10.6028/jres.092.019
_version_ 1782504085169111040
author Martinez, Richard I.
Dheandhanoo, Seksan
author_facet Martinez, Richard I.
Dheandhanoo, Seksan
author_sort Martinez, Richard I.
collection PubMed
description The energy dependence of the cross section, σ(E), for the symmetric (resonant) charge transfer reaction Ar(+)(Ar,Ar)Ar(+) was measured in our triple quadrupole (QQQ) tandem mass spectrometer. Our σ(E), for P≃0.04–0.43 mtorr and E≃5 – 60 eV (LAB) [the range of collision energies used for collisionally activated dissociation (CAD)], agrees to within 10% with the Rapp-Francis theory (impact parameter method in the two-state approximation), as corrected by Dewangan. We measured identical σ(E) from both the rate of reactant ion decay and the rate of product ion formation; i.e., our instrument is kinetically well behaved. The measurement of these σ(E) in other QQQ instruments can be used to validate whether or not a QQQ instrument has been properly designed to be kinetically well behaved. This is essential if generic, instrument-independent CAD spectral databases are to be developed on the basis of the absolute cross sections for the CAD of known ionic substructures. That is, since tandem mass spectrometry (MS/MS) exploits the ion fragmentation patterns characteristic of ionic substructures, the characteristic profiles [“breakdown curves”] of ion abundance versus target thickness (or collision energy) correspond uniquely to the sequence: (parent)(i) [Formula: see text] (daughter), [Formula: see text] (granddaughter)(k), etc. Hence, computer simulation of experimentally observed breakdown curves enables the structure of an unknown species to be assigned on the basis of the absolute cross sections σ(ij), σ(jk), etc. for CAD of known ionic substructures i, j, k, etc. Thus, if the calculated and experimental breakdown curves agree, the structure would be characterized.
format Online
Article
Text
id pubmed-5286968
institution National Center for Biotechnology Information
language English
publishDate 1987
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-52869682021-08-02 Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments Martinez, Richard I. Dheandhanoo, Seksan J Res Natl Bur Stand (1977) Article The energy dependence of the cross section, σ(E), for the symmetric (resonant) charge transfer reaction Ar(+)(Ar,Ar)Ar(+) was measured in our triple quadrupole (QQQ) tandem mass spectrometer. Our σ(E), for P≃0.04–0.43 mtorr and E≃5 – 60 eV (LAB) [the range of collision energies used for collisionally activated dissociation (CAD)], agrees to within 10% with the Rapp-Francis theory (impact parameter method in the two-state approximation), as corrected by Dewangan. We measured identical σ(E) from both the rate of reactant ion decay and the rate of product ion formation; i.e., our instrument is kinetically well behaved. The measurement of these σ(E) in other QQQ instruments can be used to validate whether or not a QQQ instrument has been properly designed to be kinetically well behaved. This is essential if generic, instrument-independent CAD spectral databases are to be developed on the basis of the absolute cross sections for the CAD of known ionic substructures. That is, since tandem mass spectrometry (MS/MS) exploits the ion fragmentation patterns characteristic of ionic substructures, the characteristic profiles [“breakdown curves”] of ion abundance versus target thickness (or collision energy) correspond uniquely to the sequence: (parent)(i) [Formula: see text] (daughter), [Formula: see text] (granddaughter)(k), etc. Hence, computer simulation of experimentally observed breakdown curves enables the structure of an unknown species to be assigned on the basis of the absolute cross sections σ(ij), σ(jk), etc. for CAD of known ionic substructures i, j, k, etc. Thus, if the calculated and experimental breakdown curves agree, the structure would be characterized. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1987 1987-06-01 /pmc/articles/PMC5286968/ http://dx.doi.org/10.6028/jres.092.019 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Bureau of Standards is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Martinez, Richard I.
Dheandhanoo, Seksan
Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments
title Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments
title_full Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments
title_fullStr Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments
title_full_unstemmed Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments
title_short Instrument-Independent CAD Spectral Databases: Absolute Cross-Section Measurements In QQQ Instruments
title_sort instrument-independent cad spectral databases: absolute cross-section measurements in qqq instruments
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5286968/
http://dx.doi.org/10.6028/jres.092.019
work_keys_str_mv AT martinezrichardi instrumentindependentcadspectraldatabasesabsolutecrosssectionmeasurementsinqqqinstruments
AT dheandhanooseksan instrumentindependentcadspectraldatabasesabsolutecrosssectionmeasurementsinqqqinstruments