Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report

INTRODUCTION: Long-term bisphosphonate therapy for osteoporosis is associated with an increased risk of low-to-no energy atypical subtrochanteric and femoral shaft fractures with characteristic radiologic findings. There are few reports of patients with long-term bisphosphonate-induced periprostheti...

Descripción completa

Detalles Bibliográficos
Autores principales: Adams, Mark R, Dunn, Conor, Sirkin, Michael S, Reilly, Mark C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5288625/
https://www.ncbi.nlm.nih.gov/pubmed/28164053
http://dx.doi.org/10.13107/jocr.2250-0685.568
_version_ 1782504362271047680
author Adams, Mark R
Dunn, Conor
Sirkin, Michael S
Reilly, Mark C
author_facet Adams, Mark R
Dunn, Conor
Sirkin, Michael S
Reilly, Mark C
author_sort Adams, Mark R
collection PubMed
description INTRODUCTION: Long-term bisphosphonate therapy for osteoporosis is associated with an increased risk of low-to-no energy atypical subtrochanteric and femoral shaft fractures with characteristic radiologic findings. There are few reports of patients with long-term bisphosphonate-induced periprosthetic fractures, all of them had a hip arthroplasty prosthesis. In this report, we present a unique case of a 90-year-old Caucasian female on long-term bisphosphonate therapy with a sliding hip screw implant who sustained a periprosthetic fracture of the femoral shaft at the distal aspect of the plate. CASE REPORT: In April 2014, a 90-year-old female presented with left thigh pain after a fall from standing height. She had a previous fixation of a left intertrochanteric hip fracture with a sliding hip screw in 1999 and a 9-year history of bisphosphonate therapy. Radiographs obtained in the emergency department revealed a left-sided femoral shaft fracture at the distal aspect of the previously applied five-hole side plate. Of note, the periprosthetic fracture demonstrated cortical thickening at the fracture site of the lateral femoral cortex, lack of comminution as well as a transverse appearance. The patient was taken to the operating room the next day for retrograde placement of an intramedullary nail of the left femur with revision of left intertrochanteric femur fracture fixation. By 3 months postoperatively, she had obtained full radiographic union. CONCLUSION: This case report highlights the possibility of an atypical fracture distal to the sliding hip screw implant after open reduction internal fixation of an intertrochanteric hip fracture in patients on long-term bisphosphonates.
format Online
Article
Text
id pubmed-5288625
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-52886252017-02-03 Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report Adams, Mark R Dunn, Conor Sirkin, Michael S Reilly, Mark C J Orthop Case Rep Case Report INTRODUCTION: Long-term bisphosphonate therapy for osteoporosis is associated with an increased risk of low-to-no energy atypical subtrochanteric and femoral shaft fractures with characteristic radiologic findings. There are few reports of patients with long-term bisphosphonate-induced periprosthetic fractures, all of them had a hip arthroplasty prosthesis. In this report, we present a unique case of a 90-year-old Caucasian female on long-term bisphosphonate therapy with a sliding hip screw implant who sustained a periprosthetic fracture of the femoral shaft at the distal aspect of the plate. CASE REPORT: In April 2014, a 90-year-old female presented with left thigh pain after a fall from standing height. She had a previous fixation of a left intertrochanteric hip fracture with a sliding hip screw in 1999 and a 9-year history of bisphosphonate therapy. Radiographs obtained in the emergency department revealed a left-sided femoral shaft fracture at the distal aspect of the previously applied five-hole side plate. Of note, the periprosthetic fracture demonstrated cortical thickening at the fracture site of the lateral femoral cortex, lack of comminution as well as a transverse appearance. The patient was taken to the operating room the next day for retrograde placement of an intramedullary nail of the left femur with revision of left intertrochanteric femur fracture fixation. By 3 months postoperatively, she had obtained full radiographic union. CONCLUSION: This case report highlights the possibility of an atypical fracture distal to the sliding hip screw implant after open reduction internal fixation of an intertrochanteric hip fracture in patients on long-term bisphosphonates. Indian Orthopaedic Research Group 2016 /pmc/articles/PMC5288625/ /pubmed/28164053 http://dx.doi.org/10.13107/jocr.2250-0685.568 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc-sa/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc-sa/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Adams, Mark R
Dunn, Conor
Sirkin, Michael S
Reilly, Mark C
Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report
title Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report
title_full Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report
title_fullStr Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report
title_full_unstemmed Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report
title_short Long-term Bisphosphonate Therapy-induced Periprosthetic Femoral Stress Fracture in a Sliding Hip Screw Implant: A Unique Case Report
title_sort long-term bisphosphonate therapy-induced periprosthetic femoral stress fracture in a sliding hip screw implant: a unique case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5288625/
https://www.ncbi.nlm.nih.gov/pubmed/28164053
http://dx.doi.org/10.13107/jocr.2250-0685.568
work_keys_str_mv AT adamsmarkr longtermbisphosphonatetherapyinducedperiprostheticfemoralstressfractureinaslidinghipscrewimplantauniquecasereport
AT dunnconor longtermbisphosphonatetherapyinducedperiprostheticfemoralstressfractureinaslidinghipscrewimplantauniquecasereport
AT sirkinmichaels longtermbisphosphonatetherapyinducedperiprostheticfemoralstressfractureinaslidinghipscrewimplantauniquecasereport
AT reillymarkc longtermbisphosphonatetherapyinducedperiprostheticfemoralstressfractureinaslidinghipscrewimplantauniquecasereport