Cargando…

Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity

This study explored the relationship between the fractional exhaled nitric oxide (FeNO) level and the efficacy of inhaled corticosteroid (ICS) in asthma-chronic obstructive pulmonary disease (COPD) overlap syndrome (ACOS) patients with different disease severity. A total of 127 ACOS patients with AC...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Jia-Xi, Lin, Yun, Lin, Jian, He, Su-Su, Chen, Mei-Fang, Wu, Xiao-Mai, Xu, You-Zu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Medical Sciences 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5290103/
https://www.ncbi.nlm.nih.gov/pubmed/28145647
http://dx.doi.org/10.3346/jkms.2017.32.3.439
_version_ 1782504592274096128
author Feng, Jia-Xi
Lin, Yun
Lin, Jian
He, Su-Su
Chen, Mei-Fang
Wu, Xiao-Mai
Xu, You-Zu
author_facet Feng, Jia-Xi
Lin, Yun
Lin, Jian
He, Su-Su
Chen, Mei-Fang
Wu, Xiao-Mai
Xu, You-Zu
author_sort Feng, Jia-Xi
collection PubMed
description This study explored the relationship between the fractional exhaled nitric oxide (FeNO) level and the efficacy of inhaled corticosteroid (ICS) in asthma-chronic obstructive pulmonary disease (COPD) overlap syndrome (ACOS) patients with different disease severity. A total of 127 ACOS patients with ACOS (case group) and 131 healthy people (control group) were enrolled in this study. Based on the severity of COPD, the ACOS patients were divided into: mild ACOS; moderate ACOS; severe ACOS; and extremely severe ACOS groups. We compared FeNO levels, pulmonary function parameters including percentage of forced expiratory volume in 1 second (FEV1) to predicted value (FEV1%pred), ratio of FEV1 to forced vital capacity (FEV1/FVC), inspiratory capacity to total lung capacity (IC/TLC) and residual volume to total lung capacity (RV/TLC), arterial blood gas parameters, including PH, arterial partial pressure of oxygen (PaO(2)) and arterial partial pressure of carbon dioxide (PaCO(2)), total serum immunoglobulin E (IgE), induced sputum eosinophil (EOS), plasma surfactant protein A (SP-A), plasma soluble receptor for advanced glycation end products (sRAGE), sputum myeloperoxidase (MPO), sputum neutrophil gelatinase-associated lipocalin (NGAL) and Asthma Control Test (ACT) scores, and COPD Assessment Test (CAT) scores. Compared with pre-treatment parameters, the FeNO levels, RV/TLC, PaCO(2), total serum IgE, induced sputum EOS, plasma SP-A, sputum MPO, sputum NGAL, and CAT scores were significantly decreased after 6 months of ICS treatment, while FEV1%pred, FEV1/FVC, IC/TLC, PH, PaO(2,) plasma sRAGE, and ACT scores were significantly increased in ACOS patients with different disease severity after 6 months of ICS treatment. This finding suggests that the FeNO level may accurately predict the efficacy of ICS in the treatment of ACOS patients.
format Online
Article
Text
id pubmed-5290103
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Academy of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-52901032017-03-01 Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity Feng, Jia-Xi Lin, Yun Lin, Jian He, Su-Su Chen, Mei-Fang Wu, Xiao-Mai Xu, You-Zu J Korean Med Sci Original Article This study explored the relationship between the fractional exhaled nitric oxide (FeNO) level and the efficacy of inhaled corticosteroid (ICS) in asthma-chronic obstructive pulmonary disease (COPD) overlap syndrome (ACOS) patients with different disease severity. A total of 127 ACOS patients with ACOS (case group) and 131 healthy people (control group) were enrolled in this study. Based on the severity of COPD, the ACOS patients were divided into: mild ACOS; moderate ACOS; severe ACOS; and extremely severe ACOS groups. We compared FeNO levels, pulmonary function parameters including percentage of forced expiratory volume in 1 second (FEV1) to predicted value (FEV1%pred), ratio of FEV1 to forced vital capacity (FEV1/FVC), inspiratory capacity to total lung capacity (IC/TLC) and residual volume to total lung capacity (RV/TLC), arterial blood gas parameters, including PH, arterial partial pressure of oxygen (PaO(2)) and arterial partial pressure of carbon dioxide (PaCO(2)), total serum immunoglobulin E (IgE), induced sputum eosinophil (EOS), plasma surfactant protein A (SP-A), plasma soluble receptor for advanced glycation end products (sRAGE), sputum myeloperoxidase (MPO), sputum neutrophil gelatinase-associated lipocalin (NGAL) and Asthma Control Test (ACT) scores, and COPD Assessment Test (CAT) scores. Compared with pre-treatment parameters, the FeNO levels, RV/TLC, PaCO(2), total serum IgE, induced sputum EOS, plasma SP-A, sputum MPO, sputum NGAL, and CAT scores were significantly decreased after 6 months of ICS treatment, while FEV1%pred, FEV1/FVC, IC/TLC, PH, PaO(2,) plasma sRAGE, and ACT scores were significantly increased in ACOS patients with different disease severity after 6 months of ICS treatment. This finding suggests that the FeNO level may accurately predict the efficacy of ICS in the treatment of ACOS patients. The Korean Academy of Medical Sciences 2017-03 2016-12-29 /pmc/articles/PMC5290103/ /pubmed/28145647 http://dx.doi.org/10.3346/jkms.2017.32.3.439 Text en © 2017 The Korean Academy of Medical Sciences. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Feng, Jia-Xi
Lin, Yun
Lin, Jian
He, Su-Su
Chen, Mei-Fang
Wu, Xiao-Mai
Xu, You-Zu
Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity
title Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity
title_full Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity
title_fullStr Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity
title_full_unstemmed Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity
title_short Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity
title_sort relationship between fractional exhaled nitric oxide level and efficacy of inhaled corticosteroid in asthma-copd overlap syndrome patients with different disease severity
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5290103/
https://www.ncbi.nlm.nih.gov/pubmed/28145647
http://dx.doi.org/10.3346/jkms.2017.32.3.439
work_keys_str_mv AT fengjiaxi relationshipbetweenfractionalexhalednitricoxidelevelandefficacyofinhaledcorticosteroidinasthmacopdoverlapsyndromepatientswithdifferentdiseaseseverity
AT linyun relationshipbetweenfractionalexhalednitricoxidelevelandefficacyofinhaledcorticosteroidinasthmacopdoverlapsyndromepatientswithdifferentdiseaseseverity
AT linjian relationshipbetweenfractionalexhalednitricoxidelevelandefficacyofinhaledcorticosteroidinasthmacopdoverlapsyndromepatientswithdifferentdiseaseseverity
AT hesusu relationshipbetweenfractionalexhalednitricoxidelevelandefficacyofinhaledcorticosteroidinasthmacopdoverlapsyndromepatientswithdifferentdiseaseseverity
AT chenmeifang relationshipbetweenfractionalexhalednitricoxidelevelandefficacyofinhaledcorticosteroidinasthmacopdoverlapsyndromepatientswithdifferentdiseaseseverity
AT wuxiaomai relationshipbetweenfractionalexhalednitricoxidelevelandefficacyofinhaledcorticosteroidinasthmacopdoverlapsyndromepatientswithdifferentdiseaseseverity
AT xuyouzu relationshipbetweenfractionalexhalednitricoxidelevelandefficacyofinhaledcorticosteroidinasthmacopdoverlapsyndromepatientswithdifferentdiseaseseverity