Cargando…

sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand

One of the greatest challenges of using a myoelectric prosthetic hand in daily life is to conveniently measure stable myoelectric signals. This study proposes a novel surface electromyography (sEMG) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy electrodes) to allow people...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Yinlai, Togane, Masami, Lu, Baoliang, Yokoi, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5292570/
https://www.ncbi.nlm.nih.gov/pubmed/28220058
http://dx.doi.org/10.3389/fnins.2017.00033
_version_ 1782504948567638016
author Jiang, Yinlai
Togane, Masami
Lu, Baoliang
Yokoi, Hiroshi
author_facet Jiang, Yinlai
Togane, Masami
Lu, Baoliang
Yokoi, Hiroshi
author_sort Jiang, Yinlai
collection PubMed
description One of the greatest challenges of using a myoelectric prosthetic hand in daily life is to conveniently measure stable myoelectric signals. This study proposes a novel surface electromyography (sEMG) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy electrodes) to allow people with disabilities to control prosthetic limbs. The PPy electrodes are sewn on an elastic band to guarantee close contact with the skin and thus reduce the contact electrical impedance between the electrodes and the skin. The sensor is highly customizable to fit the size and the shape of the stump so that people with disabilities can attach the sensor by themselves. The performance of the proposed sensor was investigated experimentally by comparing measurements of Ag/AgCl electrodes with electrolytic gel and the sEMG from the same muscle fibers. The high correlation coefficient (0.87) between the two types of sensors suggests the effectiveness of the proposed sensor. Another experiment of sEMG pattern recognition to control myoelectric prosthetic hands showed that the PPy electrodes are as effective as Ag/AgCl electrodes for measuring sEMG signals for practical myoelectric control. We also investigated the relation between the myoelectric signals' signal-to-noise ratio and the source impedances by simultaneously measuring the source impedances and the myoelectric signals with a switching circuit. The results showed that differences in both the norm and the phase of the source impedance greatly affect the common mode noise in the signal.
format Online
Article
Text
id pubmed-5292570
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-52925702017-02-20 sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand Jiang, Yinlai Togane, Masami Lu, Baoliang Yokoi, Hiroshi Front Neurosci Neuroscience One of the greatest challenges of using a myoelectric prosthetic hand in daily life is to conveniently measure stable myoelectric signals. This study proposes a novel surface electromyography (sEMG) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy electrodes) to allow people with disabilities to control prosthetic limbs. The PPy electrodes are sewn on an elastic band to guarantee close contact with the skin and thus reduce the contact electrical impedance between the electrodes and the skin. The sensor is highly customizable to fit the size and the shape of the stump so that people with disabilities can attach the sensor by themselves. The performance of the proposed sensor was investigated experimentally by comparing measurements of Ag/AgCl electrodes with electrolytic gel and the sEMG from the same muscle fibers. The high correlation coefficient (0.87) between the two types of sensors suggests the effectiveness of the proposed sensor. Another experiment of sEMG pattern recognition to control myoelectric prosthetic hands showed that the PPy electrodes are as effective as Ag/AgCl electrodes for measuring sEMG signals for practical myoelectric control. We also investigated the relation between the myoelectric signals' signal-to-noise ratio and the source impedances by simultaneously measuring the source impedances and the myoelectric signals with a switching circuit. The results showed that differences in both the norm and the phase of the source impedance greatly affect the common mode noise in the signal. Frontiers Media S.A. 2017-02-06 /pmc/articles/PMC5292570/ /pubmed/28220058 http://dx.doi.org/10.3389/fnins.2017.00033 Text en Copyright © 2017 Jiang, Togane, Lu and Yokoi. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Jiang, Yinlai
Togane, Masami
Lu, Baoliang
Yokoi, Hiroshi
sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand
title sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand
title_full sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand
title_fullStr sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand
title_full_unstemmed sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand
title_short sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand
title_sort semg sensor using polypyrrole-coated nonwoven fabric sheet for practical control of prosthetic hand
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5292570/
https://www.ncbi.nlm.nih.gov/pubmed/28220058
http://dx.doi.org/10.3389/fnins.2017.00033
work_keys_str_mv AT jiangyinlai semgsensorusingpolypyrrolecoatednonwovenfabricsheetforpracticalcontrolofprosthetichand
AT toganemasami semgsensorusingpolypyrrolecoatednonwovenfabricsheetforpracticalcontrolofprosthetichand
AT lubaoliang semgsensorusingpolypyrrolecoatednonwovenfabricsheetforpracticalcontrolofprosthetichand
AT yokoihiroshi semgsensorusingpolypyrrolecoatednonwovenfabricsheetforpracticalcontrolofprosthetichand