Cargando…

Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients

This study aims to determine the agreement of patient-measured intraocular pressure (IOP) using rebound tonometry with ophthalmologist-measured IOP using Goldmann applanation tonometry (GAT). Fifty-three glaucoma patients used rebound tonometry (Icare ONE, Icare Finland Oy., Finland) to measure thei...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Shaoying, Yu, Marco, Baig, Nafees, Hansapinyo, Linda, Tham, Clement C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5292696/
https://www.ncbi.nlm.nih.gov/pubmed/28165028
http://dx.doi.org/10.1038/srep42067
_version_ 1782504972666011648
author Tan, Shaoying
Yu, Marco
Baig, Nafees
Hansapinyo, Linda
Tham, Clement C.
author_facet Tan, Shaoying
Yu, Marco
Baig, Nafees
Hansapinyo, Linda
Tham, Clement C.
author_sort Tan, Shaoying
collection PubMed
description This study aims to determine the agreement of patient-measured intraocular pressure (IOP) using rebound tonometry with ophthalmologist-measured IOP using Goldmann applanation tonometry (GAT). Fifty-three glaucoma patients used rebound tonometry (Icare ONE, Icare Finland Oy., Finland) to measure their own IOP in ambient environments for 1 week, 5 times per day. Clinic IOP measurements were performed by ophthalmologists using GAT and by patients using rebound tonometry on examination days 1, 4 and 7 of the same week. The agreement between the two tonometries was evaluated by modified Bland-Altman plots and intra-class correlation coefficient (ICC) was determined. Differences in ICCs of them among the three examination days were evaluated by bootstrap resampling analysis. Respective within-measurement ICC of GAT and rebound tonometry were 0.98 and 0.94 on Day 1, 0.98 and 0.93 on Day 4, and 0.96 and 0.92 on Day 7. In a modified Bland-Altman plot, the mean difference ±1 standard deviation (SD) between the two tonometries was 0.15 ± 0.65 mmHg (p = 0.682). Between-measurement ICC were 0.66, 0.76 and 0.73 on the 3 examination days. There was no significant difference among ICCs. In conclusion, patient-measured IOP using rebound tonometry and ophthalmologist-measured IOP using GAT demonstrate good agreement.
format Online
Article
Text
id pubmed-5292696
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-52926962017-02-10 Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients Tan, Shaoying Yu, Marco Baig, Nafees Hansapinyo, Linda Tham, Clement C. Sci Rep Article This study aims to determine the agreement of patient-measured intraocular pressure (IOP) using rebound tonometry with ophthalmologist-measured IOP using Goldmann applanation tonometry (GAT). Fifty-three glaucoma patients used rebound tonometry (Icare ONE, Icare Finland Oy., Finland) to measure their own IOP in ambient environments for 1 week, 5 times per day. Clinic IOP measurements were performed by ophthalmologists using GAT and by patients using rebound tonometry on examination days 1, 4 and 7 of the same week. The agreement between the two tonometries was evaluated by modified Bland-Altman plots and intra-class correlation coefficient (ICC) was determined. Differences in ICCs of them among the three examination days were evaluated by bootstrap resampling analysis. Respective within-measurement ICC of GAT and rebound tonometry were 0.98 and 0.94 on Day 1, 0.98 and 0.93 on Day 4, and 0.96 and 0.92 on Day 7. In a modified Bland-Altman plot, the mean difference ±1 standard deviation (SD) between the two tonometries was 0.15 ± 0.65 mmHg (p = 0.682). Between-measurement ICC were 0.66, 0.76 and 0.73 on the 3 examination days. There was no significant difference among ICCs. In conclusion, patient-measured IOP using rebound tonometry and ophthalmologist-measured IOP using GAT demonstrate good agreement. Nature Publishing Group 2017-02-06 /pmc/articles/PMC5292696/ /pubmed/28165028 http://dx.doi.org/10.1038/srep42067 Text en Copyright © 2017, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Tan, Shaoying
Yu, Marco
Baig, Nafees
Hansapinyo, Linda
Tham, Clement C.
Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
title Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
title_full Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
title_fullStr Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
title_full_unstemmed Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
title_short Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
title_sort agreement of patient-measured intraocular pressure using rebound tonometry with goldmann applanation tonometry (gat) in glaucoma patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5292696/
https://www.ncbi.nlm.nih.gov/pubmed/28165028
http://dx.doi.org/10.1038/srep42067
work_keys_str_mv AT tanshaoying agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients
AT yumarco agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients
AT baignafees agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients
AT hansapinyolinda agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients
AT thamclementc agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients