Cargando…
Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
This study aims to determine the agreement of patient-measured intraocular pressure (IOP) using rebound tonometry with ophthalmologist-measured IOP using Goldmann applanation tonometry (GAT). Fifty-three glaucoma patients used rebound tonometry (Icare ONE, Icare Finland Oy., Finland) to measure thei...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5292696/ https://www.ncbi.nlm.nih.gov/pubmed/28165028 http://dx.doi.org/10.1038/srep42067 |
_version_ | 1782504972666011648 |
---|---|
author | Tan, Shaoying Yu, Marco Baig, Nafees Hansapinyo, Linda Tham, Clement C. |
author_facet | Tan, Shaoying Yu, Marco Baig, Nafees Hansapinyo, Linda Tham, Clement C. |
author_sort | Tan, Shaoying |
collection | PubMed |
description | This study aims to determine the agreement of patient-measured intraocular pressure (IOP) using rebound tonometry with ophthalmologist-measured IOP using Goldmann applanation tonometry (GAT). Fifty-three glaucoma patients used rebound tonometry (Icare ONE, Icare Finland Oy., Finland) to measure their own IOP in ambient environments for 1 week, 5 times per day. Clinic IOP measurements were performed by ophthalmologists using GAT and by patients using rebound tonometry on examination days 1, 4 and 7 of the same week. The agreement between the two tonometries was evaluated by modified Bland-Altman plots and intra-class correlation coefficient (ICC) was determined. Differences in ICCs of them among the three examination days were evaluated by bootstrap resampling analysis. Respective within-measurement ICC of GAT and rebound tonometry were 0.98 and 0.94 on Day 1, 0.98 and 0.93 on Day 4, and 0.96 and 0.92 on Day 7. In a modified Bland-Altman plot, the mean difference ±1 standard deviation (SD) between the two tonometries was 0.15 ± 0.65 mmHg (p = 0.682). Between-measurement ICC were 0.66, 0.76 and 0.73 on the 3 examination days. There was no significant difference among ICCs. In conclusion, patient-measured IOP using rebound tonometry and ophthalmologist-measured IOP using GAT demonstrate good agreement. |
format | Online Article Text |
id | pubmed-5292696 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-52926962017-02-10 Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients Tan, Shaoying Yu, Marco Baig, Nafees Hansapinyo, Linda Tham, Clement C. Sci Rep Article This study aims to determine the agreement of patient-measured intraocular pressure (IOP) using rebound tonometry with ophthalmologist-measured IOP using Goldmann applanation tonometry (GAT). Fifty-three glaucoma patients used rebound tonometry (Icare ONE, Icare Finland Oy., Finland) to measure their own IOP in ambient environments for 1 week, 5 times per day. Clinic IOP measurements were performed by ophthalmologists using GAT and by patients using rebound tonometry on examination days 1, 4 and 7 of the same week. The agreement between the two tonometries was evaluated by modified Bland-Altman plots and intra-class correlation coefficient (ICC) was determined. Differences in ICCs of them among the three examination days were evaluated by bootstrap resampling analysis. Respective within-measurement ICC of GAT and rebound tonometry were 0.98 and 0.94 on Day 1, 0.98 and 0.93 on Day 4, and 0.96 and 0.92 on Day 7. In a modified Bland-Altman plot, the mean difference ±1 standard deviation (SD) between the two tonometries was 0.15 ± 0.65 mmHg (p = 0.682). Between-measurement ICC were 0.66, 0.76 and 0.73 on the 3 examination days. There was no significant difference among ICCs. In conclusion, patient-measured IOP using rebound tonometry and ophthalmologist-measured IOP using GAT demonstrate good agreement. Nature Publishing Group 2017-02-06 /pmc/articles/PMC5292696/ /pubmed/28165028 http://dx.doi.org/10.1038/srep42067 Text en Copyright © 2017, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Tan, Shaoying Yu, Marco Baig, Nafees Hansapinyo, Linda Tham, Clement C. Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients |
title | Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients |
title_full | Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients |
title_fullStr | Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients |
title_full_unstemmed | Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients |
title_short | Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients |
title_sort | agreement of patient-measured intraocular pressure using rebound tonometry with goldmann applanation tonometry (gat) in glaucoma patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5292696/ https://www.ncbi.nlm.nih.gov/pubmed/28165028 http://dx.doi.org/10.1038/srep42067 |
work_keys_str_mv | AT tanshaoying agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients AT yumarco agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients AT baignafees agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients AT hansapinyolinda agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients AT thamclementc agreementofpatientmeasuredintraocularpressureusingreboundtonometrywithgoldmannapplanationtonometrygatinglaucomapatients |