Cargando…

Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography

Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption. Eighty pediatric patients a...

Descripción completa

Detalles Bibliográficos
Autores principales: Xuan, Jun, Chen, Jian, He, Hui, Jin, Hai-Ming, Zhang, Di, Wu, Yao-Sen, Tian, Nai-Feng, Wang, Xiang-Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5293422/
https://www.ncbi.nlm.nih.gov/pubmed/28151859
http://dx.doi.org/10.1097/MD.0000000000005852
_version_ 1782505077975547904
author Xuan, Jun
Chen, Jian
He, Hui
Jin, Hai-Ming
Zhang, Di
Wu, Yao-Sen
Tian, Nai-Feng
Wang, Xiang-Yang
author_facet Xuan, Jun
Chen, Jian
He, Hui
Jin, Hai-Ming
Zhang, Di
Wu, Yao-Sen
Tian, Nai-Feng
Wang, Xiang-Yang
author_sort Xuan, Jun
collection PubMed
description Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption. Eighty pediatric patients are divided into 4 age groups and their thoracic vertebrae are analyzed on computed tomography (CT) images. The maximal screw length, maximal screw diameter, screw diameter, and the cephalad angle are measured. The statistical analysis is performed using the Student's t-test and Pearson's correlation analysis. Maximal screw length increases from T9 to T12 and there are significant differences between girls and boys at T9, T10, T11, and T12 in majority of groups (P < 0.05). The maximal screw diameter and screw diameter increase from T9 to T12. The maximal screw diameter ranges from 6.27 mm to 10.20 mm, whereas the screw diameter ranges from 3.87 mm to 6.75 mm. Meanwhile, the maximum cephalad angle is 23.06° and the minimum is 13.11°. No statistically significant differences in the cephalad angle are found at all levels. Our study establishes the feasibility of 4.5 to 5.5 mm CBT screws fixation via pedicle or pedicle rib unit in the pediatric thoracic spine. The entry point of the pediatric thoracic CBT screws is 6 o’clock orientation of the pedicle. Findings of our study also provide insights into the screw insertion angle and screw size decision.
format Online
Article
Text
id pubmed-5293422
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-52934222017-02-10 Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography Xuan, Jun Chen, Jian He, Hui Jin, Hai-Ming Zhang, Di Wu, Yao-Sen Tian, Nai-Feng Wang, Xiang-Yang Medicine (Baltimore) 3200 Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption. Eighty pediatric patients are divided into 4 age groups and their thoracic vertebrae are analyzed on computed tomography (CT) images. The maximal screw length, maximal screw diameter, screw diameter, and the cephalad angle are measured. The statistical analysis is performed using the Student's t-test and Pearson's correlation analysis. Maximal screw length increases from T9 to T12 and there are significant differences between girls and boys at T9, T10, T11, and T12 in majority of groups (P < 0.05). The maximal screw diameter and screw diameter increase from T9 to T12. The maximal screw diameter ranges from 6.27 mm to 10.20 mm, whereas the screw diameter ranges from 3.87 mm to 6.75 mm. Meanwhile, the maximum cephalad angle is 23.06° and the minimum is 13.11°. No statistically significant differences in the cephalad angle are found at all levels. Our study establishes the feasibility of 4.5 to 5.5 mm CBT screws fixation via pedicle or pedicle rib unit in the pediatric thoracic spine. The entry point of the pediatric thoracic CBT screws is 6 o’clock orientation of the pedicle. Findings of our study also provide insights into the screw insertion angle and screw size decision. Wolters Kluwer Health 2017-02-03 /pmc/articles/PMC5293422/ /pubmed/28151859 http://dx.doi.org/10.1097/MD.0000000000005852 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle 3200
Xuan, Jun
Chen, Jian
He, Hui
Jin, Hai-Ming
Zhang, Di
Wu, Yao-Sen
Tian, Nai-Feng
Wang, Xiang-Yang
Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography
title Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography
title_full Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography
title_fullStr Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography
title_full_unstemmed Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography
title_short Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography
title_sort cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (t9-t12): a 2-dimensional multiplanar reconstruction study using computed tomography
topic 3200
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5293422/
https://www.ncbi.nlm.nih.gov/pubmed/28151859
http://dx.doi.org/10.1097/MD.0000000000005852
work_keys_str_mv AT xuanjun corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography
AT chenjian corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography
AT hehui corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography
AT jinhaiming corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography
AT zhangdi corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography
AT wuyaosen corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography
AT tiannaifeng corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography
AT wangxiangyang corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography