Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography
Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption. Eighty pediatric patients a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5293422/ https://www.ncbi.nlm.nih.gov/pubmed/28151859 http://dx.doi.org/10.1097/MD.0000000000005852 |
_version_ | 1782505077975547904 |
---|---|
author | Xuan, Jun Chen, Jian He, Hui Jin, Hai-Ming Zhang, Di Wu, Yao-Sen Tian, Nai-Feng Wang, Xiang-Yang |
author_facet | Xuan, Jun Chen, Jian He, Hui Jin, Hai-Ming Zhang, Di Wu, Yao-Sen Tian, Nai-Feng Wang, Xiang-Yang |
author_sort | Xuan, Jun |
collection | PubMed |
description | Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption. Eighty pediatric patients are divided into 4 age groups and their thoracic vertebrae are analyzed on computed tomography (CT) images. The maximal screw length, maximal screw diameter, screw diameter, and the cephalad angle are measured. The statistical analysis is performed using the Student's t-test and Pearson's correlation analysis. Maximal screw length increases from T9 to T12 and there are significant differences between girls and boys at T9, T10, T11, and T12 in majority of groups (P < 0.05). The maximal screw diameter and screw diameter increase from T9 to T12. The maximal screw diameter ranges from 6.27 mm to 10.20 mm, whereas the screw diameter ranges from 3.87 mm to 6.75 mm. Meanwhile, the maximum cephalad angle is 23.06° and the minimum is 13.11°. No statistically significant differences in the cephalad angle are found at all levels. Our study establishes the feasibility of 4.5 to 5.5 mm CBT screws fixation via pedicle or pedicle rib unit in the pediatric thoracic spine. The entry point of the pediatric thoracic CBT screws is 6 o’clock orientation of the pedicle. Findings of our study also provide insights into the screw insertion angle and screw size decision. |
format | Online Article Text |
id | pubmed-5293422 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-52934222017-02-10 Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography Xuan, Jun Chen, Jian He, Hui Jin, Hai-Ming Zhang, Di Wu, Yao-Sen Tian, Nai-Feng Wang, Xiang-Yang Medicine (Baltimore) 3200 Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption. Eighty pediatric patients are divided into 4 age groups and their thoracic vertebrae are analyzed on computed tomography (CT) images. The maximal screw length, maximal screw diameter, screw diameter, and the cephalad angle are measured. The statistical analysis is performed using the Student's t-test and Pearson's correlation analysis. Maximal screw length increases from T9 to T12 and there are significant differences between girls and boys at T9, T10, T11, and T12 in majority of groups (P < 0.05). The maximal screw diameter and screw diameter increase from T9 to T12. The maximal screw diameter ranges from 6.27 mm to 10.20 mm, whereas the screw diameter ranges from 3.87 mm to 6.75 mm. Meanwhile, the maximum cephalad angle is 23.06° and the minimum is 13.11°. No statistically significant differences in the cephalad angle are found at all levels. Our study establishes the feasibility of 4.5 to 5.5 mm CBT screws fixation via pedicle or pedicle rib unit in the pediatric thoracic spine. The entry point of the pediatric thoracic CBT screws is 6 o’clock orientation of the pedicle. Findings of our study also provide insights into the screw insertion angle and screw size decision. Wolters Kluwer Health 2017-02-03 /pmc/articles/PMC5293422/ /pubmed/28151859 http://dx.doi.org/10.1097/MD.0000000000005852 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | 3200 Xuan, Jun Chen, Jian He, Hui Jin, Hai-Ming Zhang, Di Wu, Yao-Sen Tian, Nai-Feng Wang, Xiang-Yang Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography |
title | Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography |
title_full | Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography |
title_fullStr | Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography |
title_full_unstemmed | Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography |
title_short | Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography |
title_sort | cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (t9-t12): a 2-dimensional multiplanar reconstruction study using computed tomography |
topic | 3200 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5293422/ https://www.ncbi.nlm.nih.gov/pubmed/28151859 http://dx.doi.org/10.1097/MD.0000000000005852 |
work_keys_str_mv | AT xuanjun corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography AT chenjian corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography AT hehui corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography AT jinhaiming corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography AT zhangdi corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography AT wuyaosen corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography AT tiannaifeng corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography AT wangxiangyang corticalbonetrajectoryscrewsplacementviapedicleorpedicleribunitinthepediatricthoracicspinet9t12a2dimensionalmultiplanarreconstructionstudyusingcomputedtomography |