Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications
We present the use of magnetoresistive sensors integrated in a microfluidic system for real-time studies of the hybridization kinetics of DNA labeled with magnetic nanoparticles to an array of surface-tethered probes. The nanoparticles were magnetized by the magnetic field from the sensor current. A...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5294463/ https://www.ncbi.nlm.nih.gov/pubmed/28167835 http://dx.doi.org/10.1038/srep41940 |
_version_ | 1782505247210471424 |
---|---|
author | Rizzi, G. Dufva, M. Hansen, M. F. |
author_facet | Rizzi, G. Dufva, M. Hansen, M. F. |
author_sort | Rizzi, G. |
collection | PubMed |
description | We present the use of magnetoresistive sensors integrated in a microfluidic system for real-time studies of the hybridization kinetics of DNA labeled with magnetic nanoparticles to an array of surface-tethered probes. The nanoparticles were magnetized by the magnetic field from the sensor current. A local negative reference ensured that only the specific binding signal was measured. Analysis of the real-time hybridization using a two-compartment model yielded both the association and dissociation constants k(on), and k(off). The effect of probe modifications with ortho-Twisted Intercalating Nucleic Acid (TINA) was studied. Such modifications have been demonstrated to increase the melting temperature of DNA hybrids in solution and are also relevant for surface-based DNA sensing. Kinetic data for DNA probes with no TINA modification or with TINA modifications at the 5′ end (1 × TINA) or at both the 5′ and 3′ ends (2 × TINA) were compared. TINA modifications were found to provide a relative decrease of k(off) by a factor of 6-20 at temperatures from 57.5 °C to 60 °C. The values of k(on) were generally in the range between 0.5-2 × 10(5) M(−1)s(−1) and showed lower values for the unmodified probe than for the TINA modified probes. The observations correlated well with measured melting temperatures of the DNA hybrids. |
format | Online Article Text |
id | pubmed-5294463 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-52944632017-02-10 Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications Rizzi, G. Dufva, M. Hansen, M. F. Sci Rep Article We present the use of magnetoresistive sensors integrated in a microfluidic system for real-time studies of the hybridization kinetics of DNA labeled with magnetic nanoparticles to an array of surface-tethered probes. The nanoparticles were magnetized by the magnetic field from the sensor current. A local negative reference ensured that only the specific binding signal was measured. Analysis of the real-time hybridization using a two-compartment model yielded both the association and dissociation constants k(on), and k(off). The effect of probe modifications with ortho-Twisted Intercalating Nucleic Acid (TINA) was studied. Such modifications have been demonstrated to increase the melting temperature of DNA hybrids in solution and are also relevant for surface-based DNA sensing. Kinetic data for DNA probes with no TINA modification or with TINA modifications at the 5′ end (1 × TINA) or at both the 5′ and 3′ ends (2 × TINA) were compared. TINA modifications were found to provide a relative decrease of k(off) by a factor of 6-20 at temperatures from 57.5 °C to 60 °C. The values of k(on) were generally in the range between 0.5-2 × 10(5) M(−1)s(−1) and showed lower values for the unmodified probe than for the TINA modified probes. The observations correlated well with measured melting temperatures of the DNA hybrids. Nature Publishing Group 2017-02-07 /pmc/articles/PMC5294463/ /pubmed/28167835 http://dx.doi.org/10.1038/srep41940 Text en Copyright © 2017, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Rizzi, G. Dufva, M. Hansen, M. F. Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications |
title | Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications |
title_full | Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications |
title_fullStr | Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications |
title_full_unstemmed | Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications |
title_short | Magnetoresistive sensors for measurements of DNA hybridization kinetics – effect of TINA modifications |
title_sort | magnetoresistive sensors for measurements of dna hybridization kinetics – effect of tina modifications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5294463/ https://www.ncbi.nlm.nih.gov/pubmed/28167835 http://dx.doi.org/10.1038/srep41940 |
work_keys_str_mv | AT rizzig magnetoresistivesensorsformeasurementsofdnahybridizationkineticseffectoftinamodifications AT dufvam magnetoresistivesensorsformeasurementsofdnahybridizationkineticseffectoftinamodifications AT hansenmf magnetoresistivesensorsformeasurementsofdnahybridizationkineticseffectoftinamodifications |