Cargando…

Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters

Operator radiation and the radiation protection efficacy of a ceiling-suspended lead screen were assessed during coronary angiography (CA) in a catheterization laboratory. An anthropomorphic phantom was placed under the X-ray beam to simulate patient attenuation in eight CA projections. Using real-t...

Descripción completa

Detalles Bibliográficos
Autores principales: Jia, Qianjun, Chen, Ziman, Jiang, Xianxian, Zhao, Zhenjun, Huang, Meiping, Li, Jiahua, Zhuang, Jian, Liu, Xiaoqing, Hu, Tianyu, Liang, Wensheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5294580/
https://www.ncbi.nlm.nih.gov/pubmed/28169334
http://dx.doi.org/10.1038/srep42077
_version_ 1782505268143194112
author Jia, Qianjun
Chen, Ziman
Jiang, Xianxian
Zhao, Zhenjun
Huang, Meiping
Li, Jiahua
Zhuang, Jian
Liu, Xiaoqing
Hu, Tianyu
Liang, Wensheng
author_facet Jia, Qianjun
Chen, Ziman
Jiang, Xianxian
Zhao, Zhenjun
Huang, Meiping
Li, Jiahua
Zhuang, Jian
Liu, Xiaoqing
Hu, Tianyu
Liang, Wensheng
author_sort Jia, Qianjun
collection PubMed
description Operator radiation and the radiation protection efficacy of a ceiling-suspended lead screen were assessed during coronary angiography (CA) in a catheterization laboratory. An anthropomorphic phantom was placed under the X-ray beam to simulate patient attenuation in eight CA projections. Using real-time dosimeters, radiation dose rates were measured on models mimicking a primary operator (PO) and an assistant. Subsequently, a ceiling-suspended lead screen was placed in three commonly used positions to compare the radiation protection efficacy. The radiation exposure to the PO was 2.3 to 227.9 (mean: 67.2 ± 49.0) μSv/min, with the left anterior oblique (LAO) 45°/cranial 25° and cranial 25° projections causing the highest and the lowest dose rates, respectively. The assistant experienced significantly less radiation overall (mean: 20.1 ± 19.6 μSv/min, P < 0.003), with the right anterior oblique (RAO) 30° and cranial 25° projections resulting in the highest and lowest exposure levels, respectively. Combined with table-side shielding, the ceiling-suspended lead screen reduced the radiation to the PO by 76.8%, 81.9% and 93.5% when placed close to the patient phantom, at the left side and close to the PO, respectively, and reduced the radiation to the assistant by 70.3%, 76.7% and 90.0%, respectively. When placed close to the PO, a ceiling-suspended lead screen provides substantial radiation protection during CA.
format Online
Article
Text
id pubmed-5294580
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-52945802017-02-10 Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters Jia, Qianjun Chen, Ziman Jiang, Xianxian Zhao, Zhenjun Huang, Meiping Li, Jiahua Zhuang, Jian Liu, Xiaoqing Hu, Tianyu Liang, Wensheng Sci Rep Article Operator radiation and the radiation protection efficacy of a ceiling-suspended lead screen were assessed during coronary angiography (CA) in a catheterization laboratory. An anthropomorphic phantom was placed under the X-ray beam to simulate patient attenuation in eight CA projections. Using real-time dosimeters, radiation dose rates were measured on models mimicking a primary operator (PO) and an assistant. Subsequently, a ceiling-suspended lead screen was placed in three commonly used positions to compare the radiation protection efficacy. The radiation exposure to the PO was 2.3 to 227.9 (mean: 67.2 ± 49.0) μSv/min, with the left anterior oblique (LAO) 45°/cranial 25° and cranial 25° projections causing the highest and the lowest dose rates, respectively. The assistant experienced significantly less radiation overall (mean: 20.1 ± 19.6 μSv/min, P < 0.003), with the right anterior oblique (RAO) 30° and cranial 25° projections resulting in the highest and lowest exposure levels, respectively. Combined with table-side shielding, the ceiling-suspended lead screen reduced the radiation to the PO by 76.8%, 81.9% and 93.5% when placed close to the patient phantom, at the left side and close to the PO, respectively, and reduced the radiation to the assistant by 70.3%, 76.7% and 90.0%, respectively. When placed close to the PO, a ceiling-suspended lead screen provides substantial radiation protection during CA. Nature Publishing Group 2017-02-07 /pmc/articles/PMC5294580/ /pubmed/28169334 http://dx.doi.org/10.1038/srep42077 Text en Copyright © 2017, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Jia, Qianjun
Chen, Ziman
Jiang, Xianxian
Zhao, Zhenjun
Huang, Meiping
Li, Jiahua
Zhuang, Jian
Liu, Xiaoqing
Hu, Tianyu
Liang, Wensheng
Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters
title Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters
title_full Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters
title_fullStr Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters
title_full_unstemmed Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters
title_short Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters
title_sort operator radiation and the efficacy of ceiling-suspended lead screen shielding during coronary angiography: an anthropomorphic phantom study using real-time dosimeters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5294580/
https://www.ncbi.nlm.nih.gov/pubmed/28169334
http://dx.doi.org/10.1038/srep42077
work_keys_str_mv AT jiaqianjun operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT chenziman operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT jiangxianxian operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT zhaozhenjun operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT huangmeiping operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT lijiahua operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT zhuangjian operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT liuxiaoqing operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT hutianyu operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters
AT liangwensheng operatorradiationandtheefficacyofceilingsuspendedleadscreenshieldingduringcoronaryangiographyananthropomorphicphantomstudyusingrealtimedosimeters