Cargando…
Investigation of Indoor Air Quality in Houses of Macedonia
People who live in buildings are exposed to harmful effects of indoor air pollution for many years. Therefore, our research is aimed to investigate the indoor air quality in family houses. The measurements of indoor air temperature, relative humidity, total volatile organic compounds (TVOC), particu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5295288/ https://www.ncbi.nlm.nih.gov/pubmed/28045447 http://dx.doi.org/10.3390/ijerph14010037 |
_version_ | 1782505405230874624 |
---|---|
author | Vilčeková, Silvia Apostoloski, Ilija Zoran Mečiarová, Ľudmila Krídlová Burdová, Eva Kiseľák, Jozef |
author_facet | Vilčeková, Silvia Apostoloski, Ilija Zoran Mečiarová, Ľudmila Krídlová Burdová, Eva Kiseľák, Jozef |
author_sort | Vilčeková, Silvia |
collection | PubMed |
description | People who live in buildings are exposed to harmful effects of indoor air pollution for many years. Therefore, our research is aimed to investigate the indoor air quality in family houses. The measurements of indoor air temperature, relative humidity, total volatile organic compounds (TVOC), particulate matters (PM) and sound pressure level were carried out in 25 houses in several cities of the Republic of Macedonia. Mean values of indoor air temperature and relative humidity ranged from 18.9 °C to 25.6 °C and from 34.1% to 68.0%, respectively. With regard to TVOC, it can be stated that excessive occurrence was recorded. Mean values ranged from 50 μg/m(3) to 2610 μg/m(3). Recommended value (200 μg/m(3)) for human exposure to TVOC was exceeded in 32% of houses. Mean concentrations of PM(2.5) (particular matter with diameter less than 2.5 µm) and PM(10) (diameter less than 10 µm) are determined to be from 16.80 µg/m(3) to 30.70 µg/m(3) and from 38.30 µg/m(3) to 74.60 µg/m(3) individually. Mean values of sound pressure level ranged from 29.8 dB(A) to 50.6 dB(A). Dependence between characteristics of buildings (Year of construction, Year of renovation, Smoke and Heating system) and data from measurements (Temperature, Relative humidity, TVOC, PM(2.5) and PM(10)) were analyzed using R software. Van der Waerden test shows dependence of Smoke on TVOC and PM(2.5). Permutational multivariate analysis of variance shows the effect of interaction of Renovation and Smoke. |
format | Online Article Text |
id | pubmed-5295288 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-52952882017-02-07 Investigation of Indoor Air Quality in Houses of Macedonia Vilčeková, Silvia Apostoloski, Ilija Zoran Mečiarová, Ľudmila Krídlová Burdová, Eva Kiseľák, Jozef Int J Environ Res Public Health Article People who live in buildings are exposed to harmful effects of indoor air pollution for many years. Therefore, our research is aimed to investigate the indoor air quality in family houses. The measurements of indoor air temperature, relative humidity, total volatile organic compounds (TVOC), particulate matters (PM) and sound pressure level were carried out in 25 houses in several cities of the Republic of Macedonia. Mean values of indoor air temperature and relative humidity ranged from 18.9 °C to 25.6 °C and from 34.1% to 68.0%, respectively. With regard to TVOC, it can be stated that excessive occurrence was recorded. Mean values ranged from 50 μg/m(3) to 2610 μg/m(3). Recommended value (200 μg/m(3)) for human exposure to TVOC was exceeded in 32% of houses. Mean concentrations of PM(2.5) (particular matter with diameter less than 2.5 µm) and PM(10) (diameter less than 10 µm) are determined to be from 16.80 µg/m(3) to 30.70 µg/m(3) and from 38.30 µg/m(3) to 74.60 µg/m(3) individually. Mean values of sound pressure level ranged from 29.8 dB(A) to 50.6 dB(A). Dependence between characteristics of buildings (Year of construction, Year of renovation, Smoke and Heating system) and data from measurements (Temperature, Relative humidity, TVOC, PM(2.5) and PM(10)) were analyzed using R software. Van der Waerden test shows dependence of Smoke on TVOC and PM(2.5). Permutational multivariate analysis of variance shows the effect of interaction of Renovation and Smoke. MDPI 2017-01-01 2017-01 /pmc/articles/PMC5295288/ /pubmed/28045447 http://dx.doi.org/10.3390/ijerph14010037 Text en © 2017 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Vilčeková, Silvia Apostoloski, Ilija Zoran Mečiarová, Ľudmila Krídlová Burdová, Eva Kiseľák, Jozef Investigation of Indoor Air Quality in Houses of Macedonia |
title | Investigation of Indoor Air Quality in Houses of Macedonia |
title_full | Investigation of Indoor Air Quality in Houses of Macedonia |
title_fullStr | Investigation of Indoor Air Quality in Houses of Macedonia |
title_full_unstemmed | Investigation of Indoor Air Quality in Houses of Macedonia |
title_short | Investigation of Indoor Air Quality in Houses of Macedonia |
title_sort | investigation of indoor air quality in houses of macedonia |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5295288/ https://www.ncbi.nlm.nih.gov/pubmed/28045447 http://dx.doi.org/10.3390/ijerph14010037 |
work_keys_str_mv | AT vilcekovasilvia investigationofindoorairqualityinhousesofmacedonia AT apostoloskiilijazoran investigationofindoorairqualityinhousesofmacedonia AT meciarovaludmila investigationofindoorairqualityinhousesofmacedonia AT kridlovaburdovaeva investigationofindoorairqualityinhousesofmacedonia AT kiselakjozef investigationofindoorairqualityinhousesofmacedonia |