Cargando…

Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts

BACKGROUND: Tapered grafts, which have a smaller diameter on the arterial side, have been increasingly used for arteriovenous fistula (AVF) formation. We compared the outcomes of 4–6-mm tapered and 6-mm straight forearm loop arteriovenous grafts. METHODS: A total of 103 patients receiving forearm lo...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Sun, Seo, Pil Won, Ryu, Jae-Wook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Thoracic and Cardiovascular Surgery 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5295480/
https://www.ncbi.nlm.nih.gov/pubmed/28180100
http://dx.doi.org/10.5090/kjtcs.2017.50.1.30
_version_ 1782505445307449344
author Han, Sun
Seo, Pil Won
Ryu, Jae-Wook
author_facet Han, Sun
Seo, Pil Won
Ryu, Jae-Wook
author_sort Han, Sun
collection PubMed
description BACKGROUND: Tapered grafts, which have a smaller diameter on the arterial side, have been increasingly used for arteriovenous fistula (AVF) formation. We compared the outcomes of 4–6-mm tapered and 6-mm straight forearm loop arteriovenous grafts. METHODS: A total of 103 patients receiving forearm loop arteriovenous grafts between March 2005 and March 2015 were retrospectively analyzed and separated into 2 groups (group A, 4- to 6-mm tapered grafts, n=78; group B, 6-mm straight grafts, n=25). In each group, complications and patency rates after surgery were assessed. RESULTS: Clinical characteristics and laboratory results, except for cerebrovascular disease history (group A, 7.7%; group B, 28.0%; p=0.014), were similar between the groups. No significant differences were found for individual complications. Kaplan-Meier survival analysis revealed no significant differences in 1-year, 3-year, and 5-year patency rates between groups (61.8%, 44.9%, and 38.5% vs. 62.7%, 41.1%, and 35.3%, respectively). CONCLUSION: We found no significant differences in complication and patency rates between the tapered and straight graft groups. If there are no differences in complication and patency between the two graft types, tapered grafts may be a valuable option for AVF formation in light of their other advantages.
format Online
Article
Text
id pubmed-5295480
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Society for Thoracic and Cardiovascular Surgery
record_format MEDLINE/PubMed
spelling pubmed-52954802017-02-08 Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts Han, Sun Seo, Pil Won Ryu, Jae-Wook Korean J Thorac Cardiovasc Surg Clinical Research BACKGROUND: Tapered grafts, which have a smaller diameter on the arterial side, have been increasingly used for arteriovenous fistula (AVF) formation. We compared the outcomes of 4–6-mm tapered and 6-mm straight forearm loop arteriovenous grafts. METHODS: A total of 103 patients receiving forearm loop arteriovenous grafts between March 2005 and March 2015 were retrospectively analyzed and separated into 2 groups (group A, 4- to 6-mm tapered grafts, n=78; group B, 6-mm straight grafts, n=25). In each group, complications and patency rates after surgery were assessed. RESULTS: Clinical characteristics and laboratory results, except for cerebrovascular disease history (group A, 7.7%; group B, 28.0%; p=0.014), were similar between the groups. No significant differences were found for individual complications. Kaplan-Meier survival analysis revealed no significant differences in 1-year, 3-year, and 5-year patency rates between groups (61.8%, 44.9%, and 38.5% vs. 62.7%, 41.1%, and 35.3%, respectively). CONCLUSION: We found no significant differences in complication and patency rates between the tapered and straight graft groups. If there are no differences in complication and patency between the two graft types, tapered grafts may be a valuable option for AVF formation in light of their other advantages. The Korean Society for Thoracic and Cardiovascular Surgery 2017-02 2017-02-05 /pmc/articles/PMC5295480/ /pubmed/28180100 http://dx.doi.org/10.5090/kjtcs.2017.50.1.30 Text en Copyright © 2017 by The Korean Society for Thoracic and Cardiovascular Surgery. All rights Reserved. This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research
Han, Sun
Seo, Pil Won
Ryu, Jae-Wook
Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts
title Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts
title_full Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts
title_fullStr Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts
title_full_unstemmed Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts
title_short Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts
title_sort surgical outcomes of forearm loop arteriovenous fistula formation using tapered versus non-tapered polytetrafluoroethylene grafts
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5295480/
https://www.ncbi.nlm.nih.gov/pubmed/28180100
http://dx.doi.org/10.5090/kjtcs.2017.50.1.30
work_keys_str_mv AT hansun surgicaloutcomesofforearmlooparteriovenousfistulaformationusingtaperedversusnontaperedpolytetrafluoroethylenegrafts
AT seopilwon surgicaloutcomesofforearmlooparteriovenousfistulaformationusingtaperedversusnontaperedpolytetrafluoroethylenegrafts
AT ryujaewook surgicaloutcomesofforearmlooparteriovenousfistulaformationusingtaperedversusnontaperedpolytetrafluoroethylenegrafts