Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy
BACKGROUND: Left ventricular (LV) dyssynchrony frequently occurs in patients with heart failure (HF). QRS ≥ 120 ms is a surrogate marker of electrical dyssynchrony, which occurs in only 30% of HF patients. In contrary, in those with normal QRS (nQRS) duration, LV dyssynchrony has been reported in 20...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elmer Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5295578/ https://www.ncbi.nlm.nih.gov/pubmed/28197282 http://dx.doi.org/10.14740/cr495w |
_version_ | 1782505464319180800 |
---|---|
author | Sinha, Santosh Kumar Bhagat, Kush Asif, Mohammad Singh, Karandeep Sachan, Mohit Mishra, Vikas Afdaali, Nasar Jha, Mukesh Jitendra Kumar, Ashutosh Singh, Shravan Sinha, Rupesh Khanra, Dibbendhu Thakur, Ramesh Varma, Chandra Mohan Krishna, Vinay Pandey, Umeshwar |
author_facet | Sinha, Santosh Kumar Bhagat, Kush Asif, Mohammad Singh, Karandeep Sachan, Mohit Mishra, Vikas Afdaali, Nasar Jha, Mukesh Jitendra Kumar, Ashutosh Singh, Shravan Sinha, Rupesh Khanra, Dibbendhu Thakur, Ramesh Varma, Chandra Mohan Krishna, Vinay Pandey, Umeshwar |
author_sort | Sinha, Santosh Kumar |
collection | PubMed |
description | BACKGROUND: Left ventricular (LV) dyssynchrony frequently occurs in patients with heart failure (HF). QRS ≥ 120 ms is a surrogate marker of electrical dyssynchrony, which occurs in only 30% of HF patients. In contrary, in those with normal QRS (nQRS) duration, LV dyssynchrony has been reported in 20-50%. This study was carried out to investigate the role of fragmented QRS (fQRS) on the surface electrocardiography (ECG) as a marker of electrical dyssynchrony to predict the presence of significant intraventricular dyssynchrony (IVD) by subsequent echocardiographic assessment. METHODS: A total of 226 consecutive patients with non-ischemic cardiomyopathy were assessed for fQRS on surface ECG as defined by presence of an additional R wave (R prime), notching in nadir of the S wave, notching of R wave, or the presence of more than one R prime (fragmentation) in two contiguous leads corresponding to a major myocardial segment. Tissue Doppler imaging (TDI) was performed in the apical views (four-chamber, two-chamber and long-axis) to analyze all 12 segments at both basal and middle levels. Time-to-peak myocardial sustained systolic (Ts) velocities were calculated. Significant systolic IVD was defined as Ts-SD > 32.6 ms as known as “Yu index”. RESULT: Of the total patients, 112 had fQRS (49.5%), while 114 had nQRS (50.5%) with male dominance (M/F = 71:29). Majority of patients were in NYHA class II (n = 122, 54%) followed by class III (n = 83; 37%), and class IV (n = 21; 9%). There were no significant differences among both groups for baseline parameters except higher QRS duration (102.42 ± 14.05 vs. 91.10 ± 13.75 ms; P = 0.001), higher Yu index (35.64 ± 12.79 vs. 20.45 ± 11.17; P = 0.01) and number of patients with positive Yu index (78.6% vs. 21.1%; P = 0.04) in group with fQRS compared with group with nQRS. fQRS complexes had 84.61% sensitivity and 80.32% specificity with positive predictive value of 78.6% and negative predictive value of 85.9% to detect IVD. On detailed segmental analysis for fQRS distribution, inferior segment had maximum (37%), followed by anterior (23%), lateral (19%), inferior and lateral (11%), anterior and inferior (8%), and anterior and lateral (2%). Among 104 patients with significant dyssynchrony, 88 patients (84.6%) had fQRS in the dyssynchronic segment. CONCLUSION: Fragmentation of QRS complex is an important predictor of electro-mechanical dyssynchrony. It is also helpful in localizing the dyssynchronous segment. In future, larger studies may be carried out to investigate the role of fQRS as a predictor of response to cardiac resynchronization therapy (CRT) in this subgroup of HF patients with narrow QRS. |
format | Online Article Text |
id | pubmed-5295578 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elmer Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-52955782017-02-14 Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy Sinha, Santosh Kumar Bhagat, Kush Asif, Mohammad Singh, Karandeep Sachan, Mohit Mishra, Vikas Afdaali, Nasar Jha, Mukesh Jitendra Kumar, Ashutosh Singh, Shravan Sinha, Rupesh Khanra, Dibbendhu Thakur, Ramesh Varma, Chandra Mohan Krishna, Vinay Pandey, Umeshwar Cardiol Res Original Article BACKGROUND: Left ventricular (LV) dyssynchrony frequently occurs in patients with heart failure (HF). QRS ≥ 120 ms is a surrogate marker of electrical dyssynchrony, which occurs in only 30% of HF patients. In contrary, in those with normal QRS (nQRS) duration, LV dyssynchrony has been reported in 20-50%. This study was carried out to investigate the role of fragmented QRS (fQRS) on the surface electrocardiography (ECG) as a marker of electrical dyssynchrony to predict the presence of significant intraventricular dyssynchrony (IVD) by subsequent echocardiographic assessment. METHODS: A total of 226 consecutive patients with non-ischemic cardiomyopathy were assessed for fQRS on surface ECG as defined by presence of an additional R wave (R prime), notching in nadir of the S wave, notching of R wave, or the presence of more than one R prime (fragmentation) in two contiguous leads corresponding to a major myocardial segment. Tissue Doppler imaging (TDI) was performed in the apical views (four-chamber, two-chamber and long-axis) to analyze all 12 segments at both basal and middle levels. Time-to-peak myocardial sustained systolic (Ts) velocities were calculated. Significant systolic IVD was defined as Ts-SD > 32.6 ms as known as “Yu index”. RESULT: Of the total patients, 112 had fQRS (49.5%), while 114 had nQRS (50.5%) with male dominance (M/F = 71:29). Majority of patients were in NYHA class II (n = 122, 54%) followed by class III (n = 83; 37%), and class IV (n = 21; 9%). There were no significant differences among both groups for baseline parameters except higher QRS duration (102.42 ± 14.05 vs. 91.10 ± 13.75 ms; P = 0.001), higher Yu index (35.64 ± 12.79 vs. 20.45 ± 11.17; P = 0.01) and number of patients with positive Yu index (78.6% vs. 21.1%; P = 0.04) in group with fQRS compared with group with nQRS. fQRS complexes had 84.61% sensitivity and 80.32% specificity with positive predictive value of 78.6% and negative predictive value of 85.9% to detect IVD. On detailed segmental analysis for fQRS distribution, inferior segment had maximum (37%), followed by anterior (23%), lateral (19%), inferior and lateral (11%), anterior and inferior (8%), and anterior and lateral (2%). Among 104 patients with significant dyssynchrony, 88 patients (84.6%) had fQRS in the dyssynchronic segment. CONCLUSION: Fragmentation of QRS complex is an important predictor of electro-mechanical dyssynchrony. It is also helpful in localizing the dyssynchronous segment. In future, larger studies may be carried out to investigate the role of fQRS as a predictor of response to cardiac resynchronization therapy (CRT) in this subgroup of HF patients with narrow QRS. Elmer Press 2016-08 2016-09-05 /pmc/articles/PMC5295578/ /pubmed/28197282 http://dx.doi.org/10.14740/cr495w Text en Copyright 2016, Sinha et al. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sinha, Santosh Kumar Bhagat, Kush Asif, Mohammad Singh, Karandeep Sachan, Mohit Mishra, Vikas Afdaali, Nasar Jha, Mukesh Jitendra Kumar, Ashutosh Singh, Shravan Sinha, Rupesh Khanra, Dibbendhu Thakur, Ramesh Varma, Chandra Mohan Krishna, Vinay Pandey, Umeshwar Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy |
title | Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy |
title_full | Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy |
title_fullStr | Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy |
title_full_unstemmed | Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy |
title_short | Fragmented QRS as a Marker of Electrical Dyssynchrony to Predict Inter-Ventricular Conduction Defect by Subsequent Echocardiographic Assessment in Symptomatic Patients of Non-Ischemic Dilated Cardiomyopathy |
title_sort | fragmented qrs as a marker of electrical dyssynchrony to predict inter-ventricular conduction defect by subsequent echocardiographic assessment in symptomatic patients of non-ischemic dilated cardiomyopathy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5295578/ https://www.ncbi.nlm.nih.gov/pubmed/28197282 http://dx.doi.org/10.14740/cr495w |
work_keys_str_mv | AT sinhasantoshkumar fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT bhagatkush fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT asifmohammad fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT singhkarandeep fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT sachanmohit fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT mishravikas fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT afdaalinasar fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT jhamukeshjitendra fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT kumarashutosh fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT singhshravan fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT sinharupesh fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT khanradibbendhu fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT thakurramesh fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT varmachandramohan fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT krishnavinay fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy AT pandeyumeshwar fragmentedqrsasamarkerofelectricaldyssynchronytopredictinterventricularconductiondefectbysubsequentechocardiographicassessmentinsymptomaticpatientsofnonischemicdilatedcardiomyopathy |