Cargando…

T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE)

PURPOSE: To optimize intracranial vessel wall imaging (VWI) at 7T for sharp wall depiction and high boundary contrast. METHODS: A variable flip angle turbo spin echo scheme (SPACE) was optimized for VWI. SPACE provides black‐blood contrast, but has less crushing effect on cerebrospinal fluid (CSF)....

Descripción completa

Detalles Bibliográficos
Autores principales: Viessmann, Olivia, Li, Linqing, Benjamin, Philip, Jezzard, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5298018/
https://www.ncbi.nlm.nih.gov/pubmed/26890988
http://dx.doi.org/10.1002/mrm.26152
_version_ 1782505821481992192
author Viessmann, Olivia
Li, Linqing
Benjamin, Philip
Jezzard, Peter
author_facet Viessmann, Olivia
Li, Linqing
Benjamin, Philip
Jezzard, Peter
author_sort Viessmann, Olivia
collection PubMed
description PURPOSE: To optimize intracranial vessel wall imaging (VWI) at 7T for sharp wall depiction and high boundary contrast. METHODS: A variable flip angle turbo spin echo scheme (SPACE) was optimized for VWI. SPACE provides black‐blood contrast, but has less crushing effect on cerebrospinal fluid (CSF). However, a delay alternating with nutation for tailored excitation (DANTE) preparation suppresses the signal from slowly moving spins of a few mm per second. Therefore, we optimized a DANTE‐preparation module for 7T. Signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and signal ratio for vessel wall, CSF, and lumen were calculated for SPACE and DANTE‐SPACE in 11 volunteers at the middle cerebral artery (MCA). An exemplar MCA stenosis patient was scanned with DANTE‐SPACE. RESULTS: The 7T‐optimized SPACE sequence improved the vessel wall point‐spread function by 17%. The CNR between the wall and CSF was doubled (12.2 versus 5.6) for the DANTE‐SPACE scans compared with the unprepared SPACE. This increase was significant in the right hemisphere (P = 0.016), but not in the left (P = 0.090). The CNR between wall and lumen was halved, but remained at a high value (24.9 versus 56.5). CONCLUSION: The optimized SPACE sequence improves VWI at 7T. Additional DANTE preparation increases the contrast between the wall and CSF. Increased outer boundary contrast comes at the cost of reduced inner boundary contrast. Magn Reson Med 77:655–663, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
format Online
Article
Text
id pubmed-5298018
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-52980182017-02-22 T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE) Viessmann, Olivia Li, Linqing Benjamin, Philip Jezzard, Peter Magn Reson Med Imaging Methodology—Full Papers PURPOSE: To optimize intracranial vessel wall imaging (VWI) at 7T for sharp wall depiction and high boundary contrast. METHODS: A variable flip angle turbo spin echo scheme (SPACE) was optimized for VWI. SPACE provides black‐blood contrast, but has less crushing effect on cerebrospinal fluid (CSF). However, a delay alternating with nutation for tailored excitation (DANTE) preparation suppresses the signal from slowly moving spins of a few mm per second. Therefore, we optimized a DANTE‐preparation module for 7T. Signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and signal ratio for vessel wall, CSF, and lumen were calculated for SPACE and DANTE‐SPACE in 11 volunteers at the middle cerebral artery (MCA). An exemplar MCA stenosis patient was scanned with DANTE‐SPACE. RESULTS: The 7T‐optimized SPACE sequence improved the vessel wall point‐spread function by 17%. The CNR between the wall and CSF was doubled (12.2 versus 5.6) for the DANTE‐SPACE scans compared with the unprepared SPACE. This increase was significant in the right hemisphere (P = 0.016), but not in the left (P = 0.090). The CNR between wall and lumen was halved, but remained at a high value (24.9 versus 56.5). CONCLUSION: The optimized SPACE sequence improves VWI at 7T. Additional DANTE preparation increases the contrast between the wall and CSF. Increased outer boundary contrast comes at the cost of reduced inner boundary contrast. Magn Reson Med 77:655–663, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2016-02-18 2017-02 /pmc/articles/PMC5298018/ /pubmed/26890988 http://dx.doi.org/10.1002/mrm.26152 Text en © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Imaging Methodology—Full Papers
Viessmann, Olivia
Li, Linqing
Benjamin, Philip
Jezzard, Peter
T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE)
title T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE)
title_full T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE)
title_fullStr T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE)
title_full_unstemmed T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE)
title_short T2‐Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE‐prepared variable flip angle turbo spin echo readout (DANTE‐SPACE)
title_sort t2‐weighted intracranial vessel wall imaging at 7 tesla using a dante‐prepared variable flip angle turbo spin echo readout (dante‐space)
topic Imaging Methodology—Full Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5298018/
https://www.ncbi.nlm.nih.gov/pubmed/26890988
http://dx.doi.org/10.1002/mrm.26152
work_keys_str_mv AT viessmannolivia t2weightedintracranialvesselwallimagingat7teslausingadantepreparedvariableflipangleturbospinechoreadoutdantespace
AT lilinqing t2weightedintracranialvesselwallimagingat7teslausingadantepreparedvariableflipangleturbospinechoreadoutdantespace
AT benjaminphilip t2weightedintracranialvesselwallimagingat7teslausingadantepreparedvariableflipangleturbospinechoreadoutdantespace
AT jezzardpeter t2weightedintracranialvesselwallimagingat7teslausingadantepreparedvariableflipangleturbospinechoreadoutdantespace