Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility

This article is a feasibility study on using fluorescence-based oil-in-water (OiW) monitors for on-line dynamic efficiency measurement of a deoiling hydrocyclone. Dynamic measurements are crucial in the design and validation of dynamic models of the hydrocyclones, and to our knowledge, no dynamic Oi...

Descripción completa

Detalles Bibliográficos
Autores principales: Durdevic, Petar, Raju, Chitra S., Bram, Mads V., Hansen, Dennis S., Yang, Zhenyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5298697/
https://www.ncbi.nlm.nih.gov/pubmed/28075371
http://dx.doi.org/10.3390/s17010124
_version_ 1782505912564449280
author Durdevic, Petar
Raju, Chitra S.
Bram, Mads V.
Hansen, Dennis S.
Yang, Zhenyu
author_facet Durdevic, Petar
Raju, Chitra S.
Bram, Mads V.
Hansen, Dennis S.
Yang, Zhenyu
author_sort Durdevic, Petar
collection PubMed
description This article is a feasibility study on using fluorescence-based oil-in-water (OiW) monitors for on-line dynamic efficiency measurement of a deoiling hydrocyclone. Dynamic measurements are crucial in the design and validation of dynamic models of the hydrocyclones, and to our knowledge, no dynamic OiW analysis of hydrocyclones has been carried out. Previous studies have extensively studied the steady state efficiency perspective of hydrocyclones, and have related them to different key parameters, such as the pressure drop ratio (PDR), inlet flow rate, and the flow-spilt. Through our study, we were able to measure the dynamics of the hydrocyclone’s efficiency [Formula: see text] response to step changes in the inlet flow rate with high accuracy. This is a breakthrough in the modelling, control, and monitoring of hydrocyclones.
format Online
Article
Text
id pubmed-5298697
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-52986972017-02-10 Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility Durdevic, Petar Raju, Chitra S. Bram, Mads V. Hansen, Dennis S. Yang, Zhenyu Sensors (Basel) Article This article is a feasibility study on using fluorescence-based oil-in-water (OiW) monitors for on-line dynamic efficiency measurement of a deoiling hydrocyclone. Dynamic measurements are crucial in the design and validation of dynamic models of the hydrocyclones, and to our knowledge, no dynamic OiW analysis of hydrocyclones has been carried out. Previous studies have extensively studied the steady state efficiency perspective of hydrocyclones, and have related them to different key parameters, such as the pressure drop ratio (PDR), inlet flow rate, and the flow-spilt. Through our study, we were able to measure the dynamics of the hydrocyclone’s efficiency [Formula: see text] response to step changes in the inlet flow rate with high accuracy. This is a breakthrough in the modelling, control, and monitoring of hydrocyclones. MDPI 2017-01-10 /pmc/articles/PMC5298697/ /pubmed/28075371 http://dx.doi.org/10.3390/s17010124 Text en © 2017 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Durdevic, Petar
Raju, Chitra S.
Bram, Mads V.
Hansen, Dennis S.
Yang, Zhenyu
Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility
title Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility
title_full Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility
title_fullStr Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility
title_full_unstemmed Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility
title_short Dynamic Oil-in-Water Concentration Acquisition on a Pilot-Scaled Offshore Water-Oil Separation Facility
title_sort dynamic oil-in-water concentration acquisition on a pilot-scaled offshore water-oil separation facility
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5298697/
https://www.ncbi.nlm.nih.gov/pubmed/28075371
http://dx.doi.org/10.3390/s17010124
work_keys_str_mv AT durdevicpetar dynamicoilinwaterconcentrationacquisitiononapilotscaledoffshorewateroilseparationfacility
AT rajuchitras dynamicoilinwaterconcentrationacquisitiononapilotscaledoffshorewateroilseparationfacility
AT brammadsv dynamicoilinwaterconcentrationacquisitiononapilotscaledoffshorewateroilseparationfacility
AT hansendenniss dynamicoilinwaterconcentrationacquisitiononapilotscaledoffshorewateroilseparationfacility
AT yangzhenyu dynamicoilinwaterconcentrationacquisitiononapilotscaledoffshorewateroilseparationfacility