Cargando…
Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model
OBJECTIVES: Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fix...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5301904/ https://www.ncbi.nlm.nih.gov/pubmed/28077394 http://dx.doi.org/10.1302/2046-3758.61.BJR-2016-0142.R1 |
_version_ | 1782506444746129408 |
---|---|
author | Scott, C. E. H. Eaton, M. J. Nutton, R. W. Wade, F. A. Evans, S. L. Pankaj, P. |
author_facet | Scott, C. E. H. Eaton, M. J. Nutton, R. W. Wade, F. A. Evans, S. L. Pankaj, P. |
author_sort | Scott, C. E. H. |
collection | PubMed |
description | OBJECTIVES: Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fixed-bearing medial UKA using a finite element model (FEM) validated experimentally by digital image correlation (DIC) and acoustic emission (AE). MATERIALS AND METHODS: A total of ten composite tibias implanted with all-polyethylene (AP) and metal-backed (MB) tibial components were loaded to 2500 N. Cortical strain was measured using DIC and cancellous microdamage using AE. FEMs were created and validated and polyethylene thickness varied from 6 mm to 10 mm. The volume of cancellous bone exposed to < -3000 µε (pathological loading) and < -7000 µε (yield point) minimum principal (compressive) microstrain and > 3000 µε and > 7000 µε maximum principal (tensile) microstrain was computed. RESULTS: Experimental AE data and the FEM volume of cancellous bone with compressive strain < -3000 µε correlated strongly: R = 0.947, R(2) = 0.847, percentage error 12.5% (p < 0.001). DIC and FEM data correlated: R = 0.838, R(2) = 0.702, percentage error 4.5% (p < 0.001). FEM strain patterns included MB lateral edge concentrations; AP concentrations at keel, peg and at the region of load application. Cancellous strains were higher in AP implants at all loads: 2.2- (10 mm) to 3.2-times (6 mm) the volume of cancellous bone compressively strained < -7000 µε. CONCLUSION: AP tibial components display greater volumes of pathologically overstrained cancellous bone than MB implants of the same geometry. Increasing AP thickness does not overcome these pathological forces and comes at the cost of greater bone resection. Cite this article: C. E. H. Scott, M. J. Eaton, R. W. Nutton, F. A. Wade, S. L. Evans, P. Pankaj. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model. Bone Joint Res 2017;6:22–30. DOI:10.1302/2046-3758.61.BJR-2016-0142.R1 |
format | Online Article Text |
id | pubmed-5301904 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
record_format | MEDLINE/PubMed |
spelling | pubmed-53019042017-02-15 Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model Scott, C. E. H. Eaton, M. J. Nutton, R. W. Wade, F. A. Evans, S. L. Pankaj, P. Bone Joint Res Knee OBJECTIVES: Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fixed-bearing medial UKA using a finite element model (FEM) validated experimentally by digital image correlation (DIC) and acoustic emission (AE). MATERIALS AND METHODS: A total of ten composite tibias implanted with all-polyethylene (AP) and metal-backed (MB) tibial components were loaded to 2500 N. Cortical strain was measured using DIC and cancellous microdamage using AE. FEMs were created and validated and polyethylene thickness varied from 6 mm to 10 mm. The volume of cancellous bone exposed to < -3000 µε (pathological loading) and < -7000 µε (yield point) minimum principal (compressive) microstrain and > 3000 µε and > 7000 µε maximum principal (tensile) microstrain was computed. RESULTS: Experimental AE data and the FEM volume of cancellous bone with compressive strain < -3000 µε correlated strongly: R = 0.947, R(2) = 0.847, percentage error 12.5% (p < 0.001). DIC and FEM data correlated: R = 0.838, R(2) = 0.702, percentage error 4.5% (p < 0.001). FEM strain patterns included MB lateral edge concentrations; AP concentrations at keel, peg and at the region of load application. Cancellous strains were higher in AP implants at all loads: 2.2- (10 mm) to 3.2-times (6 mm) the volume of cancellous bone compressively strained < -7000 µε. CONCLUSION: AP tibial components display greater volumes of pathologically overstrained cancellous bone than MB implants of the same geometry. Increasing AP thickness does not overcome these pathological forces and comes at the cost of greater bone resection. Cite this article: C. E. H. Scott, M. J. Eaton, R. W. Nutton, F. A. Wade, S. L. Evans, P. Pankaj. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model. Bone Joint Res 2017;6:22–30. DOI:10.1302/2046-3758.61.BJR-2016-0142.R1 2017-02-10 /pmc/articles/PMC5301904/ /pubmed/28077394 http://dx.doi.org/10.1302/2046-3758.61.BJR-2016-0142.R1 Text en © 2017 Scott et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited. |
spellingShingle | Knee Scott, C. E. H. Eaton, M. J. Nutton, R. W. Wade, F. A. Evans, S. L. Pankaj, P. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model |
title | Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model |
title_full | Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model |
title_fullStr | Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model |
title_full_unstemmed | Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model |
title_short | Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model |
title_sort | metal-backed versus all-polyethylene unicompartmental knee arthroplasty: proximal tibial strain in an experimentally validated finite element model |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5301904/ https://www.ncbi.nlm.nih.gov/pubmed/28077394 http://dx.doi.org/10.1302/2046-3758.61.BJR-2016-0142.R1 |
work_keys_str_mv | AT scottceh metalbackedversusallpolyethyleneunicompartmentalkneearthroplastyproximaltibialstraininanexperimentallyvalidatedfiniteelementmodel AT eatonmj metalbackedversusallpolyethyleneunicompartmentalkneearthroplastyproximaltibialstraininanexperimentallyvalidatedfiniteelementmodel AT nuttonrw metalbackedversusallpolyethyleneunicompartmentalkneearthroplastyproximaltibialstraininanexperimentallyvalidatedfiniteelementmodel AT wadefa metalbackedversusallpolyethyleneunicompartmentalkneearthroplastyproximaltibialstraininanexperimentallyvalidatedfiniteelementmodel AT evanssl metalbackedversusallpolyethyleneunicompartmentalkneearthroplastyproximaltibialstraininanexperimentallyvalidatedfiniteelementmodel AT pankajp metalbackedversusallpolyethyleneunicompartmentalkneearthroplastyproximaltibialstraininanexperimentallyvalidatedfiniteelementmodel |