Cargando…

Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT)

BACKGROUND: To compare the diagnostic accuracy of hepato-biliary (HB) phase with gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA) with dynamic contrast-enhanced MR imaging (DCEMRI) and contrast-enhanced CT (DCECT) for hepatocellular carcinoma (HCC) detection. MATERIAL/METHOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Imbriaco, Massimo, De Luca, Serena, Coppola, Milena, Fusari, Mario, Klain, Michele, Puglia, Marta, Mainenti, Pierpaolo, Liuzzi, Raffaele, Maurea, Simone
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5301959/
https://www.ncbi.nlm.nih.gov/pubmed/28217239
http://dx.doi.org/10.12659/PJR.899239
_version_ 1782506454881665024
author Imbriaco, Massimo
De Luca, Serena
Coppola, Milena
Fusari, Mario
Klain, Michele
Puglia, Marta
Mainenti, Pierpaolo
Liuzzi, Raffaele
Maurea, Simone
author_facet Imbriaco, Massimo
De Luca, Serena
Coppola, Milena
Fusari, Mario
Klain, Michele
Puglia, Marta
Mainenti, Pierpaolo
Liuzzi, Raffaele
Maurea, Simone
author_sort Imbriaco, Massimo
collection PubMed
description BACKGROUND: To compare the diagnostic accuracy of hepato-biliary (HB) phase with gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA) with dynamic contrast-enhanced MR imaging (DCEMRI) and contrast-enhanced CT (DCECT) for hepatocellular carcinoma (HCC) detection. MATERIAL/METHODS: 73 patients underwent DCECT and Gd-EOB-DTPA-3T-MR. Lesions were classified using a five-point confidence scale. Reference standard was a combination of pathological evidence and tumor growth at follow-up CT/MR at 12 months. Receiver Operating Characteristic (ROC) curves were obtained. RESULTS: A total of 125 lesions were confirmed in 73 patients. As many as 74 were HCCs and 51 were benign. Area under the curve (AUC) was 0.984 for DCEMRI+HB phase vs. 0.934 for DCEMRI (p<0.68) and 0.852 for DCECT (p<0.001). For lesions >20 mm (n.40), AUC was 0.984 for DCEMRI+HB phase, 0.999 for DCEMRI, and 0.913 for DCECT, (p=n.s.). For lesions <20 mm (n.85) AUC was 0.982 for DCEMRI+HB phase vs. 0.910 for DCEMRI (p<0.01) and 0.828 for DCECT (p<0.001). CONCLUSIONS: The addition of HB phase to DCEMRI provides an incremental accuracy of 4.5% compared to DCEMRI and DCECT for HCC detection. The accuracy of Gd-EOB-DTPA-3T-MR significantly improves for lesions <20 mm. No significant improvement is observed for lesions >20 mm and patients with Child-Pugh class B or C.
format Online
Article
Text
id pubmed-5301959
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-53019592017-02-17 Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT) Imbriaco, Massimo De Luca, Serena Coppola, Milena Fusari, Mario Klain, Michele Puglia, Marta Mainenti, Pierpaolo Liuzzi, Raffaele Maurea, Simone Pol J Radiol Original Article BACKGROUND: To compare the diagnostic accuracy of hepato-biliary (HB) phase with gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA) with dynamic contrast-enhanced MR imaging (DCEMRI) and contrast-enhanced CT (DCECT) for hepatocellular carcinoma (HCC) detection. MATERIAL/METHODS: 73 patients underwent DCECT and Gd-EOB-DTPA-3T-MR. Lesions were classified using a five-point confidence scale. Reference standard was a combination of pathological evidence and tumor growth at follow-up CT/MR at 12 months. Receiver Operating Characteristic (ROC) curves were obtained. RESULTS: A total of 125 lesions were confirmed in 73 patients. As many as 74 were HCCs and 51 were benign. Area under the curve (AUC) was 0.984 for DCEMRI+HB phase vs. 0.934 for DCEMRI (p<0.68) and 0.852 for DCECT (p<0.001). For lesions >20 mm (n.40), AUC was 0.984 for DCEMRI+HB phase, 0.999 for DCEMRI, and 0.913 for DCECT, (p=n.s.). For lesions <20 mm (n.85) AUC was 0.982 for DCEMRI+HB phase vs. 0.910 for DCEMRI (p<0.01) and 0.828 for DCECT (p<0.001). CONCLUSIONS: The addition of HB phase to DCEMRI provides an incremental accuracy of 4.5% compared to DCEMRI and DCECT for HCC detection. The accuracy of Gd-EOB-DTPA-3T-MR significantly improves for lesions <20 mm. No significant improvement is observed for lesions >20 mm and patients with Child-Pugh class B or C. International Scientific Literature, Inc. 2017-02-01 /pmc/articles/PMC5301959/ /pubmed/28217239 http://dx.doi.org/10.12659/PJR.899239 Text en © Pol J Radiol, 2017 This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited.
spellingShingle Original Article
Imbriaco, Massimo
De Luca, Serena
Coppola, Milena
Fusari, Mario
Klain, Michele
Puglia, Marta
Mainenti, Pierpaolo
Liuzzi, Raffaele
Maurea, Simone
Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT)
title Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT)
title_full Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT)
title_fullStr Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT)
title_full_unstemmed Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT)
title_short Diagnostic Accuracy of Gd-EOB-DTPA for Detection Hepatocellular Carcinoma (HCC): A Comparative Study with Dynamic Contrast Enhanced Magnetic Resonance Imaging (MRI) and Dynamic Contrast Enhanced Computed Tomography (CT)
title_sort diagnostic accuracy of gd-eob-dtpa for detection hepatocellular carcinoma (hcc): a comparative study with dynamic contrast enhanced magnetic resonance imaging (mri) and dynamic contrast enhanced computed tomography (ct)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5301959/
https://www.ncbi.nlm.nih.gov/pubmed/28217239
http://dx.doi.org/10.12659/PJR.899239
work_keys_str_mv AT imbriacomassimo diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT delucaserena diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT coppolamilena diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT fusarimario diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT klainmichele diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT pugliamarta diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT mainentipierpaolo diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT liuzziraffaele diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct
AT maureasimone diagnosticaccuracyofgdeobdtpafordetectionhepatocellularcarcinomahccacomparativestudywithdynamiccontrastenhancedmagneticresonanceimagingmrianddynamiccontrastenhancedcomputedtomographyct