Cargando…

Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits

BACKGROUND: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. PURPOSE: To determine the composition of PRP obtained...

Descripción completa

Detalles Bibliográficos
Autores principales: Fitzpatrick, Jane, Bulsara, Max K., McCrory, Paul Robert, Richardson, Martin D., Zheng, Ming Hao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
125
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5302100/
https://www.ncbi.nlm.nih.gov/pubmed/28210651
http://dx.doi.org/10.1177/2325967116675272
_version_ 1782506481211408384
author Fitzpatrick, Jane
Bulsara, Max K.
McCrory, Paul Robert
Richardson, Martin D.
Zheng, Ming Hao
author_facet Fitzpatrick, Jane
Bulsara, Max K.
McCrory, Paul Robert
Richardson, Martin D.
Zheng, Ming Hao
author_sort Fitzpatrick, Jane
collection PubMed
description BACKGROUND: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. PURPOSE: To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. STUDY DESIGN: Controlled laboratory study. METHODS: Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. RESULTS: Three kits taking samples from the “buffy coat layer” were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. CONCLUSION: This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. CLINICAL RELEVANCE: The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use.
format Online
Article
Text
id pubmed-5302100
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-53021002017-02-16 Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits Fitzpatrick, Jane Bulsara, Max K. McCrory, Paul Robert Richardson, Martin D. Zheng, Ming Hao Orthop J Sports Med 125 BACKGROUND: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. PURPOSE: To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. STUDY DESIGN: Controlled laboratory study. METHODS: Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. RESULTS: Three kits taking samples from the “buffy coat layer” were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. CONCLUSION: This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. CLINICAL RELEVANCE: The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use. SAGE Publications 2017-01-03 /pmc/articles/PMC5302100/ /pubmed/28210651 http://dx.doi.org/10.1177/2325967116675272 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc-nd/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License (http://www.creativecommons.org/licenses/by-nc-nd/3.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle 125
Fitzpatrick, Jane
Bulsara, Max K.
McCrory, Paul Robert
Richardson, Martin D.
Zheng, Ming Hao
Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits
title Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits
title_full Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits
title_fullStr Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits
title_full_unstemmed Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits
title_short Analysis of Platelet-Rich Plasma Extraction: Variations in Platelet and Blood Components Between 4 Common Commercial Kits
title_sort analysis of platelet-rich plasma extraction: variations in platelet and blood components between 4 common commercial kits
topic 125
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5302100/
https://www.ncbi.nlm.nih.gov/pubmed/28210651
http://dx.doi.org/10.1177/2325967116675272
work_keys_str_mv AT fitzpatrickjane analysisofplateletrichplasmaextractionvariationsinplateletandbloodcomponentsbetween4commoncommercialkits
AT bulsaramaxk analysisofplateletrichplasmaextractionvariationsinplateletandbloodcomponentsbetween4commoncommercialkits
AT mccrorypaulrobert analysisofplateletrichplasmaextractionvariationsinplateletandbloodcomponentsbetween4commoncommercialkits
AT richardsonmartind analysisofplateletrichplasmaextractionvariationsinplateletandbloodcomponentsbetween4commoncommercialkits
AT zhengminghao analysisofplateletrichplasmaextractionvariationsinplateletandbloodcomponentsbetween4commoncommercialkits