Cargando…

Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia

OBJECTIVES: To assess the safety and effectiveness of transthoracic echocardiography (TTE) in monitoring transcatheter closure of atrial septal defect (ASD), in comparison with conventional technique using transesophageal echocardiography (TEE). METHODS: A retrospective review of all cases of transc...

Descripción completa

Detalles Bibliográficos
Autor principal: Azhar, Ahmad S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Saudi Medical Journal 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5303796/
https://www.ncbi.nlm.nih.gov/pubmed/27761557
http://dx.doi.org/10.15537/smj.2016.11.15617
_version_ 1782506761480044544
author Azhar, Ahmad S.
author_facet Azhar, Ahmad S.
author_sort Azhar, Ahmad S.
collection PubMed
description OBJECTIVES: To assess the safety and effectiveness of transthoracic echocardiography (TTE) in monitoring transcatheter closure of atrial septal defect (ASD), in comparison with conventional technique using transesophageal echocardiography (TEE). METHODS: A retrospective review of all cases of transcatheter closure of isolated ostium secundum ASDs operated from 2005 to 2015, at the Pediatric Interventional Cardiology Department, King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia. Exclusion criteria included age ≤3 years at the time of the procedure and rim size ≤3 mm. Patients were divided into 2 groups: TTE and TEE group. Demographic and clinical baseline data, procedure data, and outcomes were compared between the 2 groups. RESULTS: We included 77 cases: 45 in TTE group and 28 in TEE (mean ± standard deviation age=8.18 ± 5.85 versus 17.68 ± 14.88), with no significant difference in ASD size, rim adequacy, or other anatomical difficulties. All (100%) patients in TEE group underwent general anesthesia, versus 8.9% in TTE group. Device deployment was comparably successful (97.8% versus 92.9%, p=0.554); while procedure time (76.27 ± 31.80 versus 119.85 ± 19.90 minutes, p<0.001) and fluoroscopy time (11.29 ± 9.04 versus 18.73 ± 11.54 minutes, p=0.003) were significantly reduced in TTE versus TEE. Prevalence of postprocedural complications was comparable in the 2 groups. CONCLUSION: Transthoracic echocardiography has non-inferior efficacy in device deployment with reference to TEE and superior safety features including significant reduction of procedure and fluoroscopy times and lesser use of general anesthesia.
format Online
Article
Text
id pubmed-5303796
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Saudi Medical Journal
record_format MEDLINE/PubMed
spelling pubmed-53037962017-02-16 Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia Azhar, Ahmad S. Saudi Med J Original Article OBJECTIVES: To assess the safety and effectiveness of transthoracic echocardiography (TTE) in monitoring transcatheter closure of atrial septal defect (ASD), in comparison with conventional technique using transesophageal echocardiography (TEE). METHODS: A retrospective review of all cases of transcatheter closure of isolated ostium secundum ASDs operated from 2005 to 2015, at the Pediatric Interventional Cardiology Department, King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia. Exclusion criteria included age ≤3 years at the time of the procedure and rim size ≤3 mm. Patients were divided into 2 groups: TTE and TEE group. Demographic and clinical baseline data, procedure data, and outcomes were compared between the 2 groups. RESULTS: We included 77 cases: 45 in TTE group and 28 in TEE (mean ± standard deviation age=8.18 ± 5.85 versus 17.68 ± 14.88), with no significant difference in ASD size, rim adequacy, or other anatomical difficulties. All (100%) patients in TEE group underwent general anesthesia, versus 8.9% in TTE group. Device deployment was comparably successful (97.8% versus 92.9%, p=0.554); while procedure time (76.27 ± 31.80 versus 119.85 ± 19.90 minutes, p<0.001) and fluoroscopy time (11.29 ± 9.04 versus 18.73 ± 11.54 minutes, p=0.003) were significantly reduced in TTE versus TEE. Prevalence of postprocedural complications was comparable in the 2 groups. CONCLUSION: Transthoracic echocardiography has non-inferior efficacy in device deployment with reference to TEE and superior safety features including significant reduction of procedure and fluoroscopy times and lesser use of general anesthesia. Saudi Medical Journal 2016-11 /pmc/articles/PMC5303796/ /pubmed/27761557 http://dx.doi.org/10.15537/smj.2016.11.15617 Text en Copyright: © Saudi Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Azhar, Ahmad S.
Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia
title Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia
title_full Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia
title_fullStr Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia
title_full_unstemmed Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia
title_short Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: Reporting a single center experience from Saudi Arabia
title_sort safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects: reporting a single center experience from saudi arabia
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5303796/
https://www.ncbi.nlm.nih.gov/pubmed/27761557
http://dx.doi.org/10.15537/smj.2016.11.15617
work_keys_str_mv AT azharahmads safetyandefficacyoftransthoracicversustransesophagealechocardiographyintranscatheterclosureofatrialseptaldefectsreportingasinglecenterexperiencefromsaudiarabia