Modified Transseptal Puncture Technique in Challenging Septa: A Randomized Comparison to Conventional Technique

Background. Transseptal puncture (TSP) can be challenging. We compared safety and efficacy of a modified TSP technique (“mosquito” technique, MOSQ-TSP) to conventional TSP (CONV-TSP). Method. Patients undergoing AF ablation in whom first attempt of TSP did not result in left atrial (LA) pressure (fa...

Descripción completa

Detalles Bibliográficos
Autores principales: Kataria, Vikas, Berte, Benjamin, Vandekerckhove, Yves, Tavernier, Rene, Duytschaever, Mattias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5303838/
https://www.ncbi.nlm.nih.gov/pubmed/28251152
http://dx.doi.org/10.1155/2017/2351925