Cargando…

Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood p...

Descripción completa

Detalles Bibliográficos
Autores principales: Koprowski, Robert, Tian, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5304312/
https://www.ncbi.nlm.nih.gov/pubmed/28250983
http://dx.doi.org/10.1155/2017/9678041
_version_ 1782506864200646656
author Koprowski, Robert
Tian, Lei
author_facet Koprowski, Robert
Tian, Lei
author_sort Koprowski, Robert
collection PubMed
description Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject's left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69 ± 0.26 (p < 0.05). The phase shift calculated for the maximum correlation is equal to 60 ± 40° (p < 0.05). When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p < 0.3). Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.
format Online
Article
Text
id pubmed-5304312
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-53043122017-03-01 Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects Koprowski, Robert Tian, Lei J Ophthalmol Research Article Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject's left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69 ± 0.26 (p < 0.05). The phase shift calculated for the maximum correlation is equal to 60 ± 40° (p < 0.05). When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p < 0.3). Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase. Hindawi Publishing Corporation 2017 2017-01-30 /pmc/articles/PMC5304312/ /pubmed/28250983 http://dx.doi.org/10.1155/2017/9678041 Text en Copyright © 2017 R. Koprowski and L. Tian. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Koprowski, Robert
Tian, Lei
Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
title Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
title_full Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
title_fullStr Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
title_full_unstemmed Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
title_short Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
title_sort quantitative assessment of the impact of blood pulsation on intraocular pressure measurement results in healthy subjects
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5304312/
https://www.ncbi.nlm.nih.gov/pubmed/28250983
http://dx.doi.org/10.1155/2017/9678041
work_keys_str_mv AT koprowskirobert quantitativeassessmentoftheimpactofbloodpulsationonintraocularpressuremeasurementresultsinhealthysubjects
AT tianlei quantitativeassessmentoftheimpactofbloodpulsationonintraocularpressuremeasurementresultsinhealthysubjects