Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood p...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5304312/ https://www.ncbi.nlm.nih.gov/pubmed/28250983 http://dx.doi.org/10.1155/2017/9678041 |
_version_ | 1782506864200646656 |
---|---|
author | Koprowski, Robert Tian, Lei |
author_facet | Koprowski, Robert Tian, Lei |
author_sort | Koprowski, Robert |
collection | PubMed |
description | Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject's left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69 ± 0.26 (p < 0.05). The phase shift calculated for the maximum correlation is equal to 60 ± 40° (p < 0.05). When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p < 0.3). Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase. |
format | Online Article Text |
id | pubmed-5304312 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-53043122017-03-01 Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects Koprowski, Robert Tian, Lei J Ophthalmol Research Article Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject's left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69 ± 0.26 (p < 0.05). The phase shift calculated for the maximum correlation is equal to 60 ± 40° (p < 0.05). When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p < 0.3). Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase. Hindawi Publishing Corporation 2017 2017-01-30 /pmc/articles/PMC5304312/ /pubmed/28250983 http://dx.doi.org/10.1155/2017/9678041 Text en Copyright © 2017 R. Koprowski and L. Tian. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Koprowski, Robert Tian, Lei Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects |
title | Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects |
title_full | Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects |
title_fullStr | Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects |
title_full_unstemmed | Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects |
title_short | Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects |
title_sort | quantitative assessment of the impact of blood pulsation on intraocular pressure measurement results in healthy subjects |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5304312/ https://www.ncbi.nlm.nih.gov/pubmed/28250983 http://dx.doi.org/10.1155/2017/9678041 |
work_keys_str_mv | AT koprowskirobert quantitativeassessmentoftheimpactofbloodpulsationonintraocularpressuremeasurementresultsinhealthysubjects AT tianlei quantitativeassessmentoftheimpactofbloodpulsationonintraocularpressuremeasurementresultsinhealthysubjects |