Cargando…

An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions....

Descripción completa

Detalles Bibliográficos
Autores principales: Naderipour, Amirreza, Asuhaimi Mohd Zin, Abdullah, Bin Habibuddin, Mohd Hafiz, Miveh, Mohammad Reza, Guerrero, Josep M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5305230/
https://www.ncbi.nlm.nih.gov/pubmed/28192436
http://dx.doi.org/10.1371/journal.pone.0164856
_version_ 1782507014423838720
author Naderipour, Amirreza
Asuhaimi Mohd Zin, Abdullah
Bin Habibuddin, Mohd Hafiz
Miveh, Mohammad Reza
Guerrero, Josep M.
author_facet Naderipour, Amirreza
Asuhaimi Mohd Zin, Abdullah
Bin Habibuddin, Mohd Hafiz
Miveh, Mohammad Reza
Guerrero, Josep M.
author_sort Naderipour, Amirreza
collection PubMed
description In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method.
format Online
Article
Text
id pubmed-5305230
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-53052302017-02-28 An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions Naderipour, Amirreza Asuhaimi Mohd Zin, Abdullah Bin Habibuddin, Mohd Hafiz Miveh, Mohammad Reza Guerrero, Josep M. PLoS One Research Article In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. Public Library of Science 2017-02-13 /pmc/articles/PMC5305230/ /pubmed/28192436 http://dx.doi.org/10.1371/journal.pone.0164856 Text en © 2017 Naderipour et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Naderipour, Amirreza
Asuhaimi Mohd Zin, Abdullah
Bin Habibuddin, Mohd Hafiz
Miveh, Mohammad Reza
Guerrero, Josep M.
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_full An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_fullStr An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_full_unstemmed An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_short An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_sort improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5305230/
https://www.ncbi.nlm.nih.gov/pubmed/28192436
http://dx.doi.org/10.1371/journal.pone.0164856
work_keys_str_mv AT naderipouramirreza animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT asuhaimimohdzinabdullah animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT binhabibuddinmohdhafiz animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT mivehmohammadreza animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT guerrerojosepm animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT naderipouramirreza improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT asuhaimimohdzinabdullah improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT binhabibuddinmohdhafiz improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT mivehmohammadreza improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions
AT guerrerojosepm improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions