An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions....
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5305230/ https://www.ncbi.nlm.nih.gov/pubmed/28192436 http://dx.doi.org/10.1371/journal.pone.0164856 |
_version_ | 1782507014423838720 |
---|---|
author | Naderipour, Amirreza Asuhaimi Mohd Zin, Abdullah Bin Habibuddin, Mohd Hafiz Miveh, Mohammad Reza Guerrero, Josep M. |
author_facet | Naderipour, Amirreza Asuhaimi Mohd Zin, Abdullah Bin Habibuddin, Mohd Hafiz Miveh, Mohammad Reza Guerrero, Josep M. |
author_sort | Naderipour, Amirreza |
collection | PubMed |
description | In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. |
format | Online Article Text |
id | pubmed-5305230 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-53052302017-02-28 An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions Naderipour, Amirreza Asuhaimi Mohd Zin, Abdullah Bin Habibuddin, Mohd Hafiz Miveh, Mohammad Reza Guerrero, Josep M. PLoS One Research Article In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. Public Library of Science 2017-02-13 /pmc/articles/PMC5305230/ /pubmed/28192436 http://dx.doi.org/10.1371/journal.pone.0164856 Text en © 2017 Naderipour et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Naderipour, Amirreza Asuhaimi Mohd Zin, Abdullah Bin Habibuddin, Mohd Hafiz Miveh, Mohammad Reza Guerrero, Josep M. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title | An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_full | An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_fullStr | An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_full_unstemmed | An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_short | An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_sort | improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5305230/ https://www.ncbi.nlm.nih.gov/pubmed/28192436 http://dx.doi.org/10.1371/journal.pone.0164856 |
work_keys_str_mv | AT naderipouramirreza animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT asuhaimimohdzinabdullah animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT binhabibuddinmohdhafiz animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT mivehmohammadreza animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT guerrerojosepm animprovedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT naderipouramirreza improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT asuhaimimohdzinabdullah improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT binhabibuddinmohdhafiz improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT mivehmohammadreza improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions AT guerrerojosepm improvedsynchronousreferenceframecurrentcontrolstrategyforaphotovoltaicgridconnectedinverterunderunbalancedandnonlinearloadconditions |