Cargando…

Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study

OBJECTIVES: Cardiomyopathy is a common complication of mitochondrial disorders, associated with increased mortality. Two dimensional speckle tracking echocardiography (2DSTE) can be used to quantify myocardial deformation. Here, we aimed to determine the usefulness of 2DSTE in detecting and monitori...

Descripción completa

Detalles Bibliográficos
Autores principales: Koene, S., Timmermans, J., Weijers, G., de Laat, P., de Korte, C. L., Smeitink, J. A. M., Janssen, M. C. H., Kapusta, L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5306433/
https://www.ncbi.nlm.nih.gov/pubmed/28054208
http://dx.doi.org/10.1007/s10545-016-0001-7
_version_ 1782507198900862976
author Koene, S.
Timmermans, J.
Weijers, G.
de Laat, P.
de Korte, C. L.
Smeitink, J. A. M.
Janssen, M. C. H.
Kapusta, L.
author_facet Koene, S.
Timmermans, J.
Weijers, G.
de Laat, P.
de Korte, C. L.
Smeitink, J. A. M.
Janssen, M. C. H.
Kapusta, L.
author_sort Koene, S.
collection PubMed
description OBJECTIVES: Cardiomyopathy is a common complication of mitochondrial disorders, associated with increased mortality. Two dimensional speckle tracking echocardiography (2DSTE) can be used to quantify myocardial deformation. Here, we aimed to determine the usefulness of 2DSTE in detecting and monitoring subtle changes in myocardial dysfunction in carriers of the 3243A>G mutation in mitochondrial DNA. METHODS: In this retrospective pilot study, 30 symptomatic and asymptomatic carriers of the mitochondrial 3243A>G mutation of whom two subsequent echocardiograms were available were included. We measured longitudinal, circumferential and radial strain using 2DSTE. Results were compared to published reference values. RESULTS: Speckle tracking was feasible in 90 % of the patients for longitudinal strain. Circumferential and radial strain showed low face validity (low number of images with sufficient quality; suboptimal tracking) and were therefore rejected for further analysis. Global longitudinal strain showed good face validity, and was abnormal in 56–70 % (depending on reference values used) of the carriers (n = 27). Reproducibility was good (mean difference of 0.83 for inter- and 0.40 for intra-rater reproducibility; ICC 0.78 and 0.89, respectively). The difference between the first and the second measurement exceeded the measurement variance in 39 % of the cases (n = 23; feasibility of follow-up 77 %). DISCUSSION: Even in data collected as part of clinical care, two-dimensional strain echocardiography seems a feasible method to detect and monitor subtle changes in longitudinal myocardial deformation in adult carriers of the mitochondrial 3243A>G mutation. Based on our data and the reported accuracy of global longitudinal strain in other studies, we suggest the use of global longitudinal strain in a prospective follow-up or intervention study. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10545-016-0001-7) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5306433
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-53064332017-02-27 Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study Koene, S. Timmermans, J. Weijers, G. de Laat, P. de Korte, C. L. Smeitink, J. A. M. Janssen, M. C. H. Kapusta, L. J Inherit Metab Dis Original Article OBJECTIVES: Cardiomyopathy is a common complication of mitochondrial disorders, associated with increased mortality. Two dimensional speckle tracking echocardiography (2DSTE) can be used to quantify myocardial deformation. Here, we aimed to determine the usefulness of 2DSTE in detecting and monitoring subtle changes in myocardial dysfunction in carriers of the 3243A>G mutation in mitochondrial DNA. METHODS: In this retrospective pilot study, 30 symptomatic and asymptomatic carriers of the mitochondrial 3243A>G mutation of whom two subsequent echocardiograms were available were included. We measured longitudinal, circumferential and radial strain using 2DSTE. Results were compared to published reference values. RESULTS: Speckle tracking was feasible in 90 % of the patients for longitudinal strain. Circumferential and radial strain showed low face validity (low number of images with sufficient quality; suboptimal tracking) and were therefore rejected for further analysis. Global longitudinal strain showed good face validity, and was abnormal in 56–70 % (depending on reference values used) of the carriers (n = 27). Reproducibility was good (mean difference of 0.83 for inter- and 0.40 for intra-rater reproducibility; ICC 0.78 and 0.89, respectively). The difference between the first and the second measurement exceeded the measurement variance in 39 % of the cases (n = 23; feasibility of follow-up 77 %). DISCUSSION: Even in data collected as part of clinical care, two-dimensional strain echocardiography seems a feasible method to detect and monitor subtle changes in longitudinal myocardial deformation in adult carriers of the mitochondrial 3243A>G mutation. Based on our data and the reported accuracy of global longitudinal strain in other studies, we suggest the use of global longitudinal strain in a prospective follow-up or intervention study. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10545-016-0001-7) contains supplementary material, which is available to authorized users. Springer Netherlands 2017-01-04 2017 /pmc/articles/PMC5306433/ /pubmed/28054208 http://dx.doi.org/10.1007/s10545-016-0001-7 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Koene, S.
Timmermans, J.
Weijers, G.
de Laat, P.
de Korte, C. L.
Smeitink, J. A. M.
Janssen, M. C. H.
Kapusta, L.
Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study
title Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study
title_full Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study
title_fullStr Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study
title_full_unstemmed Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study
title_short Is 2D speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243A>G carriers? — a retrospective pilot study
title_sort is 2d speckle tracking echocardiography useful for detecting and monitoring myocardial dysfunction in adult m.3243a>g carriers? — a retrospective pilot study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5306433/
https://www.ncbi.nlm.nih.gov/pubmed/28054208
http://dx.doi.org/10.1007/s10545-016-0001-7
work_keys_str_mv AT koenes is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy
AT timmermansj is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy
AT weijersg is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy
AT delaatp is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy
AT dekortecl is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy
AT smeitinkjam is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy
AT janssenmch is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy
AT kapustal is2dspeckletrackingechocardiographyusefulfordetectingandmonitoringmyocardialdysfunctioninadultm3243agcarriersaretrospectivepilotstudy