Cargando…

Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials

INTRODUCTION: Badly broken or structurally compromised posterior teeth are frequently associated with crown/root fracture. Numerous restorative materials have been used to fabricate indirect full-coverage restorations for such teeth. This study aims to evaluate and compare the effect of restorative...

Descripción completa

Detalles Bibliográficos
Autores principales: D’souza, Kathleen Manuela, Aras, Meena Ajay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5308080/
https://www.ncbi.nlm.nih.gov/pubmed/28216846
http://dx.doi.org/10.4103/0972-4052.197938
_version_ 1782507487200542720
author D’souza, Kathleen Manuela
Aras, Meena Ajay
author_facet D’souza, Kathleen Manuela
Aras, Meena Ajay
author_sort D’souza, Kathleen Manuela
collection PubMed
description INTRODUCTION: Badly broken or structurally compromised posterior teeth are frequently associated with crown/root fracture. Numerous restorative materials have been used to fabricate indirect full-coverage restorations for such teeth. This study aims to evaluate and compare the effect of restorative materials on the stress distribution pattern in a mandibular first molar tooth, under varying loading conditions and to compare the stress distribution pattern in five commonly used indirect restorative materials. MATERIALS AND METHODS: Five three-dimensional finite element models representing a mandibular first molar tooth restored with crowns of gold, porcelain fused to metal, composite (Artglass), alumina-based zirconia (In-Ceram Zirconia [ICZ]), and double-layered zirconia-based materials (zirconia core veneered with porcelain, Lava) were constructed, using a Finite Element Analysis Software (ANSYS version 10; ANSYS Inc., Canonsburg, PA, USA). Two loading conditions were applied, simulating maximum bite force of 600 N axially and normal masticatory bite force of 225 N axially and nonaxially. RESULTS: Both all-ceramic crowns allowed the least amount of stress distribution to the surrounding tooth structure. In maximum bite force-simulation test, alumina-based all-ceramic crown displayed the highest von Mises stresses (123.745 MPa). In the masticatory bite force-simulation test, both all-ceramic crowns (122.503–133.13 MPa) displayed the highest von Mises stresses. CONCLUSIONS: ICZ crown displayed the highest peak von Mises stress values under maximum and masticatory bite forces. ICZ and Lava crowns also allowed the least amount of stress distribution to the surrounding tooth structure, which is indicative of a favorable response of the underlying tooth structure to the overlying full-coverage indirect restorative material. These results suggest that ICZ and Lava crowns can be recommended for clinical use in cases of badly damaged teeth.
format Online
Article
Text
id pubmed-5308080
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-53080802018-01-01 Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials D’souza, Kathleen Manuela Aras, Meena Ajay J Indian Prosthodont Soc Original Article INTRODUCTION: Badly broken or structurally compromised posterior teeth are frequently associated with crown/root fracture. Numerous restorative materials have been used to fabricate indirect full-coverage restorations for such teeth. This study aims to evaluate and compare the effect of restorative materials on the stress distribution pattern in a mandibular first molar tooth, under varying loading conditions and to compare the stress distribution pattern in five commonly used indirect restorative materials. MATERIALS AND METHODS: Five three-dimensional finite element models representing a mandibular first molar tooth restored with crowns of gold, porcelain fused to metal, composite (Artglass), alumina-based zirconia (In-Ceram Zirconia [ICZ]), and double-layered zirconia-based materials (zirconia core veneered with porcelain, Lava) were constructed, using a Finite Element Analysis Software (ANSYS version 10; ANSYS Inc., Canonsburg, PA, USA). Two loading conditions were applied, simulating maximum bite force of 600 N axially and normal masticatory bite force of 225 N axially and nonaxially. RESULTS: Both all-ceramic crowns allowed the least amount of stress distribution to the surrounding tooth structure. In maximum bite force-simulation test, alumina-based all-ceramic crown displayed the highest von Mises stresses (123.745 MPa). In the masticatory bite force-simulation test, both all-ceramic crowns (122.503–133.13 MPa) displayed the highest von Mises stresses. CONCLUSIONS: ICZ crown displayed the highest peak von Mises stress values under maximum and masticatory bite forces. ICZ and Lava crowns also allowed the least amount of stress distribution to the surrounding tooth structure, which is indicative of a favorable response of the underlying tooth structure to the overlying full-coverage indirect restorative material. These results suggest that ICZ and Lava crowns can be recommended for clinical use in cases of badly damaged teeth. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5308080/ /pubmed/28216846 http://dx.doi.org/10.4103/0972-4052.197938 Text en Copyright: © 2017 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
D’souza, Kathleen Manuela
Aras, Meena Ajay
Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials
title Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials
title_full Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials
title_fullStr Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials
title_full_unstemmed Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials
title_short Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials
title_sort three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5308080/
https://www.ncbi.nlm.nih.gov/pubmed/28216846
http://dx.doi.org/10.4103/0972-4052.197938
work_keys_str_mv AT dsouzakathleenmanuela threedimensionalfiniteelementanalysisofthestressdistributionpatterninamandibularfirstmolartoothrestoredwithfivedifferentrestorativematerials
AT arasmeenaajay threedimensionalfiniteelementanalysisofthestressdistributionpatterninamandibularfirstmolartoothrestoredwithfivedifferentrestorativematerials