Cargando…
Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant
Auditory brainstem implantation has become a key technique for the rehabilitation of hearing in patients with neurofibromatosis type 2. The nature of this devastating genetic disease requires ongoing MRI for the patient's lifespan. Today, most auditory brainstem implants require removal of the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2017
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5309127/ https://www.ncbi.nlm.nih.gov/pubmed/28210535 http://dx.doi.org/10.1055/s-0036-1597588 |
_version_ | 1782507661559857152 |
---|---|
author | Shew, Matthew Bertsch, Judson Camarata, Paul Staecker, Hinrich |
author_facet | Shew, Matthew Bertsch, Judson Camarata, Paul Staecker, Hinrich |
author_sort | Shew, Matthew |
collection | PubMed |
description | Auditory brainstem implantation has become a key technique for the rehabilitation of hearing in patients with neurofibromatosis type 2. The nature of this devastating genetic disease requires ongoing MRI for the patient's lifespan. Today, most auditory brainstem implants require removal of the magnet that connects the internal device to the external speech processor to undergo imaging as their disease progresses. Patients have the option of having a short procedure to have the magnet taken out and replaced each time, or alternately using a headband to secure the processor over the receiver coil of the internal device. Novel magnet technology has led to the development of a freely rotating magnet that can be used inside the magnetic field of an MRI scanner without losing magnet strength and without being displaced from the body of the device. We report one of the first patients implanted with a Med-El Synchrony ABI in the United States who subsequently underwent successful imaging with MRI 1.5 tesla to follow for other existing schwannomas. |
format | Online Article Text |
id | pubmed-5309127 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-53091272017-02-16 Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant Shew, Matthew Bertsch, Judson Camarata, Paul Staecker, Hinrich J Neurol Surg Rep Auditory brainstem implantation has become a key technique for the rehabilitation of hearing in patients with neurofibromatosis type 2. The nature of this devastating genetic disease requires ongoing MRI for the patient's lifespan. Today, most auditory brainstem implants require removal of the magnet that connects the internal device to the external speech processor to undergo imaging as their disease progresses. Patients have the option of having a short procedure to have the magnet taken out and replaced each time, or alternately using a headband to secure the processor over the receiver coil of the internal device. Novel magnet technology has led to the development of a freely rotating magnet that can be used inside the magnetic field of an MRI scanner without losing magnet strength and without being displaced from the body of the device. We report one of the first patients implanted with a Med-El Synchrony ABI in the United States who subsequently underwent successful imaging with MRI 1.5 tesla to follow for other existing schwannomas. Georg Thieme Verlag KG 2017-01 /pmc/articles/PMC5309127/ /pubmed/28210535 http://dx.doi.org/10.1055/s-0036-1597588 Text en © Thieme Medical Publishers |
spellingShingle | Shew, Matthew Bertsch, Judson Camarata, Paul Staecker, Hinrich Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant |
title | Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant |
title_full | Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant |
title_fullStr | Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant |
title_full_unstemmed | Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant |
title_short | Magnetic Resonance Imaging in a Neurofibromatosis Type 2 Patient with a Novel MRI-Compatible Auditory Brainstem Implant |
title_sort | magnetic resonance imaging in a neurofibromatosis type 2 patient with a novel mri-compatible auditory brainstem implant |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5309127/ https://www.ncbi.nlm.nih.gov/pubmed/28210535 http://dx.doi.org/10.1055/s-0036-1597588 |
work_keys_str_mv | AT shewmatthew magneticresonanceimaginginaneurofibromatosistype2patientwithanovelmricompatibleauditorybrainstemimplant AT bertschjudson magneticresonanceimaginginaneurofibromatosistype2patientwithanovelmricompatibleauditorybrainstemimplant AT camaratapaul magneticresonanceimaginginaneurofibromatosistype2patientwithanovelmricompatibleauditorybrainstemimplant AT staeckerhinrich magneticresonanceimaginginaneurofibromatosistype2patientwithanovelmricompatibleauditorybrainstemimplant |