Cargando…
Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection
Early detection of HIV infection is the best way to prevent spread of the disease and to improve the efficiency of the antiretroviral therapy. Nucleic acid amplification tests (NAAT) have become the gold-standard for detecting low-concentrations of the virus in blood. However, these methods are tech...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5310927/ https://www.ncbi.nlm.nih.gov/pubmed/28199410 http://dx.doi.org/10.1371/journal.pone.0171899 |
_version_ | 1782507946846978048 |
---|---|
author | Kosaka, Priscila M. Pini, Valerio Calleja, Montserrat Tamayo, Javier |
author_facet | Kosaka, Priscila M. Pini, Valerio Calleja, Montserrat Tamayo, Javier |
author_sort | Kosaka, Priscila M. |
collection | PubMed |
description | Early detection of HIV infection is the best way to prevent spread of the disease and to improve the efficiency of the antiretroviral therapy. Nucleic acid amplification tests (NAAT) have become the gold-standard for detecting low-concentrations of the virus in blood. However, these methods are technically demanding and cost-prohibitive in developing countries. Immunoassays are more affordable and can be more easily adapted for point-of-care diagnosis. However, the sensitivity so far of these methods has been too low. We here report the development of a sandwich immunoassay that combines nanomechanical and optoplasmonic transduction methods for detecting the HIV-1 capsid antigen p24 in human serum. The immunoreactions take place on the surface of a compliant microcantilever where gold nanoparticles are used as both mechanical and plasmonic labels. The microcantilever acts as both a mechanical resonator and an optical cavity for the transduction of the mechanical and plasmonic signals. The limit of detection of the immunoassay is 10(−17) g/mL that is equivalent to one virion in 10 mL of plasma. This is 5 orders of magnitude better than last generation of approved immunoassays and 2 orders of magnitude better than NAAT. This technology meets the demands to be produced en masse at low cost and the capability for miniaturization to be used at the point-of-care. |
format | Online Article Text |
id | pubmed-5310927 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-53109272017-03-03 Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection Kosaka, Priscila M. Pini, Valerio Calleja, Montserrat Tamayo, Javier PLoS One Research Article Early detection of HIV infection is the best way to prevent spread of the disease and to improve the efficiency of the antiretroviral therapy. Nucleic acid amplification tests (NAAT) have become the gold-standard for detecting low-concentrations of the virus in blood. However, these methods are technically demanding and cost-prohibitive in developing countries. Immunoassays are more affordable and can be more easily adapted for point-of-care diagnosis. However, the sensitivity so far of these methods has been too low. We here report the development of a sandwich immunoassay that combines nanomechanical and optoplasmonic transduction methods for detecting the HIV-1 capsid antigen p24 in human serum. The immunoreactions take place on the surface of a compliant microcantilever where gold nanoparticles are used as both mechanical and plasmonic labels. The microcantilever acts as both a mechanical resonator and an optical cavity for the transduction of the mechanical and plasmonic signals. The limit of detection of the immunoassay is 10(−17) g/mL that is equivalent to one virion in 10 mL of plasma. This is 5 orders of magnitude better than last generation of approved immunoassays and 2 orders of magnitude better than NAAT. This technology meets the demands to be produced en masse at low cost and the capability for miniaturization to be used at the point-of-care. Public Library of Science 2017-02-15 /pmc/articles/PMC5310927/ /pubmed/28199410 http://dx.doi.org/10.1371/journal.pone.0171899 Text en © 2017 Kosaka et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kosaka, Priscila M. Pini, Valerio Calleja, Montserrat Tamayo, Javier Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection |
title | Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection |
title_full | Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection |
title_fullStr | Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection |
title_full_unstemmed | Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection |
title_short | Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection |
title_sort | ultrasensitive detection of hiv-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting hiv-1 at first week after infection |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5310927/ https://www.ncbi.nlm.nih.gov/pubmed/28199410 http://dx.doi.org/10.1371/journal.pone.0171899 |
work_keys_str_mv | AT kosakapriscilam ultrasensitivedetectionofhiv1p24antigenbyahybridnanomechanicaloptoplasmonicplatformwithpotentialfordetectinghiv1atfirstweekafterinfection AT pinivalerio ultrasensitivedetectionofhiv1p24antigenbyahybridnanomechanicaloptoplasmonicplatformwithpotentialfordetectinghiv1atfirstweekafterinfection AT callejamontserrat ultrasensitivedetectionofhiv1p24antigenbyahybridnanomechanicaloptoplasmonicplatformwithpotentialfordetectinghiv1atfirstweekafterinfection AT tamayojavier ultrasensitivedetectionofhiv1p24antigenbyahybridnanomechanicaloptoplasmonicplatformwithpotentialfordetectinghiv1atfirstweekafterinfection |