Cargando…

A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures

BACKGROUND: The purpose of this study was to determine optimal treatment of stable tibial shaft fractures using intramedullary nailing (IMN) or casting. MATERIALS AND METHODS: We performed a multi-center prospective study cohort. Patients with stable tibia shaft fractures meeting Sarmiento’s criteri...

Descripción completa

Detalles Bibliográficos
Autores principales: Obremskey, William T., Cutrera, Norele, Kidd, Christopher M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5311003/
https://www.ncbi.nlm.nih.gov/pubmed/27770336
http://dx.doi.org/10.1007/s10195-016-0429-4
_version_ 1782507951700836352
author Obremskey, William T.
Cutrera, Norele
Kidd, Christopher M.
author_facet Obremskey, William T.
Cutrera, Norele
Kidd, Christopher M.
author_sort Obremskey, William T.
collection PubMed
description BACKGROUND: The purpose of this study was to determine optimal treatment of stable tibial shaft fractures using intramedullary nailing (IMN) or casting. MATERIALS AND METHODS: We performed a multi-center prospective study cohort. Patients with stable tibia shaft fractures meeting Sarmiento’s criteria (isolated closed fractures with less than 12 mm of shortening and 10° of angulation) were enrolled prospectively and treated with either a reamed IMN with static interlocking screws or closed reduction followed by long-leg casting. Both groups were weight bearing following surgery. Radiographs were taken until union, and range of motion of knee and ankle joints was assessed. Malalignment (>5°) and malunion (>10°) were determined. Functional outcome measures using short musculoskeletal assessment scores (SMFA) and a knee pain score were scheduled at 6 weeks, 3 months and 6 months. RESULTS: At 3 months, differences between the casting and IMN groups were noted in return to work (6/15 vs 3/17, P < 0.05); ankle dorsiflexion (7° vs 12°, P < 0.05); plantar flexion (28° vs 39°, P < 0.05); and SMFA domains of Dysfunction Index, Bother Index, daily activities, emotional status, and arm/hand function (P < 0.05). The SMFA mobility function demonstrated a significant trend (P = 0.065). At 6 months, malalignment was present in 3/15 in the casting group and in 1/17 in the IMN group (P = 0.02). Malunion was present in 1/15 in the cast group. One fracture in the casting group went on to nonunion and required late IMN placement at 7 months and eventually healed. There were no differences in ankle motion, SMFA scores, or return to work. There was no difference in knee pain between the groups as measured by VAS and Court-Brown pain scale at 6 months. CONCLUSIONS: Patients with stable tibia fractures treated with intramedullary nailing have improved clinical and functional outcomes at 3 months compared with those treated with casting, but there are no differences in any other outcome measure. Patients treated in a cast may have a higher incidence of malalignment or malunion. LEVEL OF EVIDENCE: Level-II prognostic.
format Online
Article
Text
id pubmed-5311003
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-53110032017-02-28 A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures Obremskey, William T. Cutrera, Norele Kidd, Christopher M. J Orthop Traumatol Original Article BACKGROUND: The purpose of this study was to determine optimal treatment of stable tibial shaft fractures using intramedullary nailing (IMN) or casting. MATERIALS AND METHODS: We performed a multi-center prospective study cohort. Patients with stable tibia shaft fractures meeting Sarmiento’s criteria (isolated closed fractures with less than 12 mm of shortening and 10° of angulation) were enrolled prospectively and treated with either a reamed IMN with static interlocking screws or closed reduction followed by long-leg casting. Both groups were weight bearing following surgery. Radiographs were taken until union, and range of motion of knee and ankle joints was assessed. Malalignment (>5°) and malunion (>10°) were determined. Functional outcome measures using short musculoskeletal assessment scores (SMFA) and a knee pain score were scheduled at 6 weeks, 3 months and 6 months. RESULTS: At 3 months, differences between the casting and IMN groups were noted in return to work (6/15 vs 3/17, P < 0.05); ankle dorsiflexion (7° vs 12°, P < 0.05); plantar flexion (28° vs 39°, P < 0.05); and SMFA domains of Dysfunction Index, Bother Index, daily activities, emotional status, and arm/hand function (P < 0.05). The SMFA mobility function demonstrated a significant trend (P = 0.065). At 6 months, malalignment was present in 3/15 in the casting group and in 1/17 in the IMN group (P = 0.02). Malunion was present in 1/15 in the cast group. One fracture in the casting group went on to nonunion and required late IMN placement at 7 months and eventually healed. There were no differences in ankle motion, SMFA scores, or return to work. There was no difference in knee pain between the groups as measured by VAS and Court-Brown pain scale at 6 months. CONCLUSIONS: Patients with stable tibia fractures treated with intramedullary nailing have improved clinical and functional outcomes at 3 months compared with those treated with casting, but there are no differences in any other outcome measure. Patients treated in a cast may have a higher incidence of malalignment or malunion. LEVEL OF EVIDENCE: Level-II prognostic. Springer International Publishing 2016-10-21 2017-03 /pmc/articles/PMC5311003/ /pubmed/27770336 http://dx.doi.org/10.1007/s10195-016-0429-4 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Obremskey, William T.
Cutrera, Norele
Kidd, Christopher M.
A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures
title A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures
title_full A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures
title_fullStr A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures
title_full_unstemmed A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures
title_short A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures
title_sort prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5311003/
https://www.ncbi.nlm.nih.gov/pubmed/27770336
http://dx.doi.org/10.1007/s10195-016-0429-4
work_keys_str_mv AT obremskeywilliamt aprospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures
AT cutreranorele aprospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures
AT kiddchristopherm aprospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures
AT aprospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures
AT obremskeywilliamt prospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures
AT cutreranorele prospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures
AT kiddchristopherm prospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures
AT prospectivemulticenterstudyofintramedullarynailingvscastingofstabletibialshaftfractures