Cargando…
Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study
Surgery patients in Japan undergo routine spirometry testing prior to general anesthesia. The use of a flow sensor during general anesthesia has recently become common. However, it is not certain whether the information derived from flow-volume curves is being adequately used for mechanical ventilat...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5315306/ https://www.ncbi.nlm.nih.gov/pubmed/28212451 http://dx.doi.org/10.1371/journal.pone.0172421 |
Sumario: | Surgery patients in Japan undergo routine spirometry testing prior to general anesthesia. The use of a flow sensor during general anesthesia has recently become common. However, it is not certain whether the information derived from flow-volume curves is being adequately used for mechanical ventilation management during general anesthesia. So far, there have been no attempts to calculate airway resistance using flow-volume curves. Therefore, we performed a prospective, observational study to investigate the relationship between pre-anesthetic and intra-anesthetic airway resistance in patients scheduled for surgery under general anesthesia. We calculated pre-anesthetic and intra-anesthetic airway resistance in each patient, based on the slopes of flow-volume curves obtained prior to and during general anesthesia. We also calculated endotracheal tube resistance to correct the intra-anesthetic airway resistance values calculated. A total of 526 patients were included in the study, and 98 patients had a forced expiratory volume in the first second/forced vital capacity ratio of < 70%. Pre-anesthetic airway resistance was significantly higher in patients with airflow obstruction than in those without airflow obstruction (p < 0.001), whereas no significant difference in intra-anesthetic airway resistance was found between patients with and without airflow obstruction during mechanical ventilation (p = 0.48). Pre-anesthetic and intra-anesthetic airway resistance values were closer to each other in patients without airflow obstruction, with a mean difference < 1.0 cmH(2)O L(-1)s(-1), than in those with airflow obstruction, although these respiratory parameters were significantly different (p < 0.001). Intra-anesthetic airway resistance was not related to the FEV1/FVC ratio, regardless of the degree to which the FEV1/FVC ratio reflected pre-anesthetic airway resistance. As compared with patients with airflow obstruction, the mean difference between pre-anesthetic and intra-anesthetic airway resistance was small in patients without airflow obstruction. |
---|