Cargando…

Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation

Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). T...

Descripción completa

Detalles Bibliográficos
Autores principales: Mansouri, Mahdi, Gregory, Shaun D., Salamonsen, Robert F., Lovell, Nigel H., Stevens, Michael C., Pauls, Jo P., Akmeliawati, Rini, Lim, Einly
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5315328/
https://www.ncbi.nlm.nih.gov/pubmed/28212401
http://dx.doi.org/10.1371/journal.pone.0172393
_version_ 1782508671784189952
author Mansouri, Mahdi
Gregory, Shaun D.
Salamonsen, Robert F.
Lovell, Nigel H.
Stevens, Michael C.
Pauls, Jo P.
Akmeliawati, Rini
Lim, Einly
author_facet Mansouri, Mahdi
Gregory, Shaun D.
Salamonsen, Robert F.
Lovell, Nigel H.
Stevens, Michael C.
Pauls, Jo P.
Akmeliawati, Rini
Lim, Einly
author_sort Mansouri, Mahdi
collection PubMed
description Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow ([Image: see text] ) with respect to mean left ventricular end diastolic pressure (PLVED(m)) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVED(m)) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased [Image: see text] by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVED(m) of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and [Image: see text] with CSC, whilst the SLC maintained MAP and [Image: see text] . The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation.
format Online
Article
Text
id pubmed-5315328
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-53153282017-03-03 Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation Mansouri, Mahdi Gregory, Shaun D. Salamonsen, Robert F. Lovell, Nigel H. Stevens, Michael C. Pauls, Jo P. Akmeliawati, Rini Lim, Einly PLoS One Research Article Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow ([Image: see text] ) with respect to mean left ventricular end diastolic pressure (PLVED(m)) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVED(m)) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased [Image: see text] by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVED(m) of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and [Image: see text] with CSC, whilst the SLC maintained MAP and [Image: see text] . The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation. Public Library of Science 2017-02-17 /pmc/articles/PMC5315328/ /pubmed/28212401 http://dx.doi.org/10.1371/journal.pone.0172393 Text en © 2017 Mansouri et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mansouri, Mahdi
Gregory, Shaun D.
Salamonsen, Robert F.
Lovell, Nigel H.
Stevens, Michael C.
Pauls, Jo P.
Akmeliawati, Rini
Lim, Einly
Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation
title Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation
title_full Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation
title_fullStr Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation
title_full_unstemmed Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation
title_short Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation
title_sort preload-based starling-like control of rotary blood pumps: an in-vitro evaluation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5315328/
https://www.ncbi.nlm.nih.gov/pubmed/28212401
http://dx.doi.org/10.1371/journal.pone.0172393
work_keys_str_mv AT mansourimahdi preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation
AT gregoryshaund preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation
AT salamonsenrobertf preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation
AT lovellnigelh preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation
AT stevensmichaelc preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation
AT paulsjop preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation
AT akmeliawatirini preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation
AT limeinly preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation