Cargando…
Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation
Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). T...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5315328/ https://www.ncbi.nlm.nih.gov/pubmed/28212401 http://dx.doi.org/10.1371/journal.pone.0172393 |
_version_ | 1782508671784189952 |
---|---|
author | Mansouri, Mahdi Gregory, Shaun D. Salamonsen, Robert F. Lovell, Nigel H. Stevens, Michael C. Pauls, Jo P. Akmeliawati, Rini Lim, Einly |
author_facet | Mansouri, Mahdi Gregory, Shaun D. Salamonsen, Robert F. Lovell, Nigel H. Stevens, Michael C. Pauls, Jo P. Akmeliawati, Rini Lim, Einly |
author_sort | Mansouri, Mahdi |
collection | PubMed |
description | Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow ([Image: see text] ) with respect to mean left ventricular end diastolic pressure (PLVED(m)) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVED(m)) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased [Image: see text] by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVED(m) of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and [Image: see text] with CSC, whilst the SLC maintained MAP and [Image: see text] . The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation. |
format | Online Article Text |
id | pubmed-5315328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-53153282017-03-03 Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation Mansouri, Mahdi Gregory, Shaun D. Salamonsen, Robert F. Lovell, Nigel H. Stevens, Michael C. Pauls, Jo P. Akmeliawati, Rini Lim, Einly PLoS One Research Article Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow ([Image: see text] ) with respect to mean left ventricular end diastolic pressure (PLVED(m)) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVED(m)) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased [Image: see text] by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVED(m) of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and [Image: see text] with CSC, whilst the SLC maintained MAP and [Image: see text] . The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation. Public Library of Science 2017-02-17 /pmc/articles/PMC5315328/ /pubmed/28212401 http://dx.doi.org/10.1371/journal.pone.0172393 Text en © 2017 Mansouri et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Mansouri, Mahdi Gregory, Shaun D. Salamonsen, Robert F. Lovell, Nigel H. Stevens, Michael C. Pauls, Jo P. Akmeliawati, Rini Lim, Einly Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation |
title | Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation |
title_full | Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation |
title_fullStr | Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation |
title_full_unstemmed | Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation |
title_short | Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation |
title_sort | preload-based starling-like control of rotary blood pumps: an in-vitro evaluation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5315328/ https://www.ncbi.nlm.nih.gov/pubmed/28212401 http://dx.doi.org/10.1371/journal.pone.0172393 |
work_keys_str_mv | AT mansourimahdi preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation AT gregoryshaund preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation AT salamonsenrobertf preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation AT lovellnigelh preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation AT stevensmichaelc preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation AT paulsjop preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation AT akmeliawatirini preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation AT limeinly preloadbasedstarlinglikecontrolofrotarybloodpumpsaninvitroevaluation |