Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus
OBJECTIVE: To evaluate the performance of the FreeStyle Libre Flash continuous glucose monitoring (FSL-CGM) system against established central laboratory methods. RESEARCH DESIGN AND METHODS: 20 subjects (8 type 1 diabetes mellitus, 12 type 2 diabetes mellitus) were analyzed. FSL-CGM sensor measurem...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5316912/ https://www.ncbi.nlm.nih.gov/pubmed/28243449 http://dx.doi.org/10.1136/bmjdrc-2016-000320 |
_version_ | 1782508916295335936 |
---|---|
author | Fokkert, M J van Dijk, P R Edens, M A Abbes, S de Jong, D Slingerland, R J Bilo, H J G |
author_facet | Fokkert, M J van Dijk, P R Edens, M A Abbes, S de Jong, D Slingerland, R J Bilo, H J G |
author_sort | Fokkert, M J |
collection | PubMed |
description | OBJECTIVE: To evaluate the performance of the FreeStyle Libre Flash continuous glucose monitoring (FSL-CGM) system against established central laboratory methods. RESEARCH DESIGN AND METHODS: 20 subjects (8 type 1 diabetes mellitus, 12 type 2 diabetes mellitus) were analyzed. FSL-CGM sensor measurements (inserted in arm and abdomen) were compared with capillary blood glucose results analyzed with StatStrip as semigold standard. The glucose response after a standardized oral glucose load was measured by FSL-CGM and capillary samples analyzed by perchloric acid hexokinase (PCA-HK) method, StatStrip and FSL test strip (FSLC), and a commonly used CGM system (iPro2). RESULTS: FSL-CGM arm sensor readings showed 85.5% of paired readings falling within Clarke Error Grid (ISO 15197:2013) zone A when compared with StatStrip. For FSL-CGM abdomen and FSLC, these percentages were 64% and 98%, respectively. The overall correlation of FSL-CGM in the arm and the StatStrip indicates a performance with lower results with the FSL-CGM in the arm than expected based on the StatStrip in the lower glucose ranges, and higher results than expected in the higher ranges. Following a standardized glucose load, a slower rise in glucose level was observed for FSL-CGM arm as compared with PCA-HK, StatStrip, FSLC, and iPro2 during the first 45–60 min after glucose load ingestion. CONCLUSIONS: Certain matters need attention while using the FSL-CGM in daily life including the observed lower values in the lower ranges, and the underestimation of the effect of a meal on glucose response. These effects of such deviations can partly be overcome by optimizing the available user instructions. TRIAL REGISTRATION NUMBER: TC5348; results. |
format | Online Article Text |
id | pubmed-5316912 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-53169122017-02-27 Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus Fokkert, M J van Dijk, P R Edens, M A Abbes, S de Jong, D Slingerland, R J Bilo, H J G BMJ Open Diabetes Res Care Emerging Technologies and Therapeutics OBJECTIVE: To evaluate the performance of the FreeStyle Libre Flash continuous glucose monitoring (FSL-CGM) system against established central laboratory methods. RESEARCH DESIGN AND METHODS: 20 subjects (8 type 1 diabetes mellitus, 12 type 2 diabetes mellitus) were analyzed. FSL-CGM sensor measurements (inserted in arm and abdomen) were compared with capillary blood glucose results analyzed with StatStrip as semigold standard. The glucose response after a standardized oral glucose load was measured by FSL-CGM and capillary samples analyzed by perchloric acid hexokinase (PCA-HK) method, StatStrip and FSL test strip (FSLC), and a commonly used CGM system (iPro2). RESULTS: FSL-CGM arm sensor readings showed 85.5% of paired readings falling within Clarke Error Grid (ISO 15197:2013) zone A when compared with StatStrip. For FSL-CGM abdomen and FSLC, these percentages were 64% and 98%, respectively. The overall correlation of FSL-CGM in the arm and the StatStrip indicates a performance with lower results with the FSL-CGM in the arm than expected based on the StatStrip in the lower glucose ranges, and higher results than expected in the higher ranges. Following a standardized glucose load, a slower rise in glucose level was observed for FSL-CGM arm as compared with PCA-HK, StatStrip, FSLC, and iPro2 during the first 45–60 min after glucose load ingestion. CONCLUSIONS: Certain matters need attention while using the FSL-CGM in daily life including the observed lower values in the lower ranges, and the underestimation of the effect of a meal on glucose response. These effects of such deviations can partly be overcome by optimizing the available user instructions. TRIAL REGISTRATION NUMBER: TC5348; results. BMJ Publishing Group 2017-02-17 /pmc/articles/PMC5316912/ /pubmed/28243449 http://dx.doi.org/10.1136/bmjdrc-2016-000320 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Emerging Technologies and Therapeutics Fokkert, M J van Dijk, P R Edens, M A Abbes, S de Jong, D Slingerland, R J Bilo, H J G Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus |
title | Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus |
title_full | Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus |
title_fullStr | Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus |
title_full_unstemmed | Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus |
title_short | Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus |
title_sort | performance of the freestyle libre flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus |
topic | Emerging Technologies and Therapeutics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5316912/ https://www.ncbi.nlm.nih.gov/pubmed/28243449 http://dx.doi.org/10.1136/bmjdrc-2016-000320 |
work_keys_str_mv | AT fokkertmj performanceofthefreestylelibreflashglucosemonitoringsysteminpatientswithtype1and2diabetesmellitus AT vandijkpr performanceofthefreestylelibreflashglucosemonitoringsysteminpatientswithtype1and2diabetesmellitus AT edensma performanceofthefreestylelibreflashglucosemonitoringsysteminpatientswithtype1and2diabetesmellitus AT abbess performanceofthefreestylelibreflashglucosemonitoringsysteminpatientswithtype1and2diabetesmellitus AT dejongd performanceofthefreestylelibreflashglucosemonitoringsysteminpatientswithtype1and2diabetesmellitus AT slingerlandrj performanceofthefreestylelibreflashglucosemonitoringsysteminpatientswithtype1and2diabetesmellitus AT bilohjg performanceofthefreestylelibreflashglucosemonitoringsysteminpatientswithtype1and2diabetesmellitus |