Cargando…

Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials

OBJECTIVES: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed part...

Descripción completa

Detalles Bibliográficos
Autores principales: Nazari, Vahideh, Ghodsi, Safoura, Alikhasi, Marzieh, Sahebi, Majid, Shamshiri, Ahmad Reza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318496/
https://www.ncbi.nlm.nih.gov/pubmed/28243301
_version_ 1782509201459773440
author Nazari, Vahideh
Ghodsi, Safoura
Alikhasi, Marzieh
Sahebi, Majid
Shamshiri, Ahmad Reza
author_facet Nazari, Vahideh
Ghodsi, Safoura
Alikhasi, Marzieh
Sahebi, Majid
Shamshiri, Ahmad Reza
author_sort Nazari, Vahideh
collection PubMed
description OBJECTIVES: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs) with excessive crown height, fabricated from three different materials. MATERIALS AND METHODS: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr), and polyetheretherketone (PEEK) (n=10). After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05. RESULTS: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001). The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively. CONCLUSIONS: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions) in the molar region with excessive CHS.
format Online
Article
Text
id pubmed-5318496
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-53184962017-02-27 Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials Nazari, Vahideh Ghodsi, Safoura Alikhasi, Marzieh Sahebi, Majid Shamshiri, Ahmad Reza J Dent (Tehran) Original Article OBJECTIVES: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs) with excessive crown height, fabricated from three different materials. MATERIALS AND METHODS: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr), and polyetheretherketone (PEEK) (n=10). After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05. RESULTS: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001). The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively. CONCLUSIONS: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions) in the molar region with excessive CHS. Tehran University of Medical Sciences 2016-11 /pmc/articles/PMC5318496/ /pubmed/28243301 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Nazari, Vahideh
Ghodsi, Safoura
Alikhasi, Marzieh
Sahebi, Majid
Shamshiri, Ahmad Reza
Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials
title Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials
title_full Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials
title_fullStr Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials
title_full_unstemmed Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials
title_short Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials
title_sort fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318496/
https://www.ncbi.nlm.nih.gov/pubmed/28243301
work_keys_str_mv AT nazarivahideh fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials
AT ghodsisafoura fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials
AT alikhasimarzieh fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials
AT sahebimajid fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials
AT shamshiriahmadreza fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials