Cargando…
Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials
OBJECTIVES: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed part...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318496/ https://www.ncbi.nlm.nih.gov/pubmed/28243301 |
_version_ | 1782509201459773440 |
---|---|
author | Nazari, Vahideh Ghodsi, Safoura Alikhasi, Marzieh Sahebi, Majid Shamshiri, Ahmad Reza |
author_facet | Nazari, Vahideh Ghodsi, Safoura Alikhasi, Marzieh Sahebi, Majid Shamshiri, Ahmad Reza |
author_sort | Nazari, Vahideh |
collection | PubMed |
description | OBJECTIVES: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs) with excessive crown height, fabricated from three different materials. MATERIALS AND METHODS: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr), and polyetheretherketone (PEEK) (n=10). After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05. RESULTS: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001). The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively. CONCLUSIONS: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions) in the molar region with excessive CHS. |
format | Online Article Text |
id | pubmed-5318496 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Tehran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-53184962017-02-27 Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials Nazari, Vahideh Ghodsi, Safoura Alikhasi, Marzieh Sahebi, Majid Shamshiri, Ahmad Reza J Dent (Tehran) Original Article OBJECTIVES: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs) with excessive crown height, fabricated from three different materials. MATERIALS AND METHODS: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr), and polyetheretherketone (PEEK) (n=10). After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05. RESULTS: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001). The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively. CONCLUSIONS: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions) in the molar region with excessive CHS. Tehran University of Medical Sciences 2016-11 /pmc/articles/PMC5318496/ /pubmed/28243301 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Nazari, Vahideh Ghodsi, Safoura Alikhasi, Marzieh Sahebi, Majid Shamshiri, Ahmad Reza Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials |
title | Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials |
title_full | Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials |
title_fullStr | Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials |
title_full_unstemmed | Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials |
title_short | Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials |
title_sort | fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318496/ https://www.ncbi.nlm.nih.gov/pubmed/28243301 |
work_keys_str_mv | AT nazarivahideh fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials AT ghodsisafoura fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials AT alikhasimarzieh fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials AT sahebimajid fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials AT shamshiriahmadreza fracturestrengthofthreeunitimplantsupportedfixedpartialdentureswithexcessivecrownheightfabricatedfromdifferentmaterials |