Cargando…

Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion

OBJECTIVES: This study aimed to determine the effect of surface treatments such as tooth reduction and extending the etching time on microtensile bond strength (μTBS) of composite resin to normal and fluorotic enamel after microabrasion. MATERIALS AND METHODS: Fifty non-carious anterior teeth were c...

Descripción completa

Detalles Bibliográficos
Autores principales: Bassir, Mahshid Mohammadi, Rezvani, Mohammad Bagher, Ghomsheh, Elham Tabatabai, Hosseini, Zahra Malek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318500/
https://www.ncbi.nlm.nih.gov/pubmed/28243305
_version_ 1782509202356305920
author Bassir, Mahshid Mohammadi
Rezvani, Mohammad Bagher
Ghomsheh, Elham Tabatabai
Hosseini, Zahra Malek
author_facet Bassir, Mahshid Mohammadi
Rezvani, Mohammad Bagher
Ghomsheh, Elham Tabatabai
Hosseini, Zahra Malek
author_sort Bassir, Mahshid Mohammadi
collection PubMed
description OBJECTIVES: This study aimed to determine the effect of surface treatments such as tooth reduction and extending the etching time on microtensile bond strength (μTBS) of composite resin to normal and fluorotic enamel after microabrasion. MATERIALS AND METHODS: Fifty non-carious anterior teeth were classified into two groups of normal and fluorotic (n=25) using Thylstrup and Fejerskov index (TFI=4–6). Teeth in each group were treated with five modalities as follows and restored with OptiBond FL and Z350 composite resin: 1-Etching (30 seconds), bonding, filling (B); 2-Tooth reduction (0.3mm), etching, bonding, filling (R-B); 3-Microabrasion (120 seconds), etching, bonding, filling (MB); 4- Microabrasion, tooth reduction, etching, bonding, filling (M-R-B); and 5- Microabrasion, etching (60 seconds), bonding, filling (M-2E-B). Ten experimental groups (n=5) were designed; 150 rectangular samples (10 in each group) with a cross-sectional area of 1×1mm(2) were prepared for μTBS test. Failure mode was determined under a stereomicroscope and one specimen was selected from each group for scanning electron microscopy (SEM) analysis. Data were analyzed using two-way ANOVA and Tukey’s test. RESULTS: The μTBS to normal enamel was higher than to fluorotic enamel in all groups except for group (R-B). The Maximum and minimum μTBS were noted in the group (normal, reduction, bonding) and (fluorosed, microabrasion, bonding), respectively. Tooth reduction increased μTBS more effectively than extended etching time after microabrasion. CONCLUSIONS: Fluorosis may reduce μTBS of composite resin to enamel. Microabrasion reduced the bond strength. Tooth reduction and extended etching time increased μTBS of composite resin to both normal and fluorotic enamel.
format Online
Article
Text
id pubmed-5318500
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-53185002017-02-27 Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion Bassir, Mahshid Mohammadi Rezvani, Mohammad Bagher Ghomsheh, Elham Tabatabai Hosseini, Zahra Malek J Dent (Tehran) Original Article OBJECTIVES: This study aimed to determine the effect of surface treatments such as tooth reduction and extending the etching time on microtensile bond strength (μTBS) of composite resin to normal and fluorotic enamel after microabrasion. MATERIALS AND METHODS: Fifty non-carious anterior teeth were classified into two groups of normal and fluorotic (n=25) using Thylstrup and Fejerskov index (TFI=4–6). Teeth in each group were treated with five modalities as follows and restored with OptiBond FL and Z350 composite resin: 1-Etching (30 seconds), bonding, filling (B); 2-Tooth reduction (0.3mm), etching, bonding, filling (R-B); 3-Microabrasion (120 seconds), etching, bonding, filling (MB); 4- Microabrasion, tooth reduction, etching, bonding, filling (M-R-B); and 5- Microabrasion, etching (60 seconds), bonding, filling (M-2E-B). Ten experimental groups (n=5) were designed; 150 rectangular samples (10 in each group) with a cross-sectional area of 1×1mm(2) were prepared for μTBS test. Failure mode was determined under a stereomicroscope and one specimen was selected from each group for scanning electron microscopy (SEM) analysis. Data were analyzed using two-way ANOVA and Tukey’s test. RESULTS: The μTBS to normal enamel was higher than to fluorotic enamel in all groups except for group (R-B). The Maximum and minimum μTBS were noted in the group (normal, reduction, bonding) and (fluorosed, microabrasion, bonding), respectively. Tooth reduction increased μTBS more effectively than extended etching time after microabrasion. CONCLUSIONS: Fluorosis may reduce μTBS of composite resin to enamel. Microabrasion reduced the bond strength. Tooth reduction and extended etching time increased μTBS of composite resin to both normal and fluorotic enamel. Tehran University of Medical Sciences 2016-11 /pmc/articles/PMC5318500/ /pubmed/28243305 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Bassir, Mahshid Mohammadi
Rezvani, Mohammad Bagher
Ghomsheh, Elham Tabatabai
Hosseini, Zahra Malek
Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion
title Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion
title_full Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion
title_fullStr Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion
title_full_unstemmed Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion
title_short Effect of Different Surface Treatments on Microtensile Bond Strength of Composite Resin to Normal and Fluorotic Enamel After Microabrasion
title_sort effect of different surface treatments on microtensile bond strength of composite resin to normal and fluorotic enamel after microabrasion
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318500/
https://www.ncbi.nlm.nih.gov/pubmed/28243305
work_keys_str_mv AT bassirmahshidmohammadi effectofdifferentsurfacetreatmentsonmicrotensilebondstrengthofcompositeresintonormalandfluoroticenamelaftermicroabrasion
AT rezvanimohammadbagher effectofdifferentsurfacetreatmentsonmicrotensilebondstrengthofcompositeresintonormalandfluoroticenamelaftermicroabrasion
AT ghomshehelhamtabatabai effectofdifferentsurfacetreatmentsonmicrotensilebondstrengthofcompositeresintonormalandfluoroticenamelaftermicroabrasion
AT hosseinizahramalek effectofdifferentsurfacetreatmentsonmicrotensilebondstrengthofcompositeresintonormalandfluoroticenamelaftermicroabrasion