Cargando…
Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series
Purpose. To evaluate efficacy and safety of a trabecular micro-bypass stent system when used as the sole procedure in Japanese patients with medically uncontrolled primary open-angle glaucoma (POAG). Design. Prospective nonrandomized interventional pilot study. Methods. Ten eyes of 10 Japanese patie...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318622/ https://www.ncbi.nlm.nih.gov/pubmed/28265466 http://dx.doi.org/10.1155/2017/9605461 |
_version_ | 1782509222096797696 |
---|---|
author | Shiba, Daisuke Hosoda, Shingo Yaguchi, Saori Ozeki, Naoki Yuki, Kenya Tsubota, Kazuo |
author_facet | Shiba, Daisuke Hosoda, Shingo Yaguchi, Saori Ozeki, Naoki Yuki, Kenya Tsubota, Kazuo |
author_sort | Shiba, Daisuke |
collection | PubMed |
description | Purpose. To evaluate efficacy and safety of a trabecular micro-bypass stent system when used as the sole procedure in Japanese patients with medically uncontrolled primary open-angle glaucoma (POAG). Design. Prospective nonrandomized interventional pilot study. Methods. Ten eyes of 10 Japanese patients with medically uncontrolled POAG taking three ocular hypotensive medications were treated using only the implantation of two iStent trabecular micro-bypass stents. Each patient continued to take the same ocular hypotensive medications used preoperatively throughout the study. Intraocular pressure (IOP) and endothelial cell density (ECD) were determined at baseline and at 1, 3, and 6 months postoperatively. Best-corrected visual acuity (BCVA) was measured at baseline and 6 months after surgery. Results. Mean IOP was 22.0 ± 3.0 mmHg at baseline and 16.9 ± 3.6 mmHg at 6 months, which represented a mean reduction of 5.1 mmHg or 23.2%. No significant changes were observed in the ECD and BCVA. Complications that occurred during the early postoperative period included hyphema, peripheral anterior synechiae, and occlusion of the stent by the iris. Conclusion. Implantation of two trabecular micro-bypass stents as the sole procedure in Japanese POAG patients effectively reduced IOP and exhibited a favorable safety profile. Clinical Trials Registration number is UMIN000004002. |
format | Online Article Text |
id | pubmed-5318622 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-53186222017-03-06 Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series Shiba, Daisuke Hosoda, Shingo Yaguchi, Saori Ozeki, Naoki Yuki, Kenya Tsubota, Kazuo J Ophthalmol Clinical Study Purpose. To evaluate efficacy and safety of a trabecular micro-bypass stent system when used as the sole procedure in Japanese patients with medically uncontrolled primary open-angle glaucoma (POAG). Design. Prospective nonrandomized interventional pilot study. Methods. Ten eyes of 10 Japanese patients with medically uncontrolled POAG taking three ocular hypotensive medications were treated using only the implantation of two iStent trabecular micro-bypass stents. Each patient continued to take the same ocular hypotensive medications used preoperatively throughout the study. Intraocular pressure (IOP) and endothelial cell density (ECD) were determined at baseline and at 1, 3, and 6 months postoperatively. Best-corrected visual acuity (BCVA) was measured at baseline and 6 months after surgery. Results. Mean IOP was 22.0 ± 3.0 mmHg at baseline and 16.9 ± 3.6 mmHg at 6 months, which represented a mean reduction of 5.1 mmHg or 23.2%. No significant changes were observed in the ECD and BCVA. Complications that occurred during the early postoperative period included hyphema, peripheral anterior synechiae, and occlusion of the stent by the iris. Conclusion. Implantation of two trabecular micro-bypass stents as the sole procedure in Japanese POAG patients effectively reduced IOP and exhibited a favorable safety profile. Clinical Trials Registration number is UMIN000004002. Hindawi Publishing Corporation 2017 2017-02-07 /pmc/articles/PMC5318622/ /pubmed/28265466 http://dx.doi.org/10.1155/2017/9605461 Text en Copyright © 2017 Daisuke Shiba et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Shiba, Daisuke Hosoda, Shingo Yaguchi, Saori Ozeki, Naoki Yuki, Kenya Tsubota, Kazuo Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series |
title | Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series |
title_full | Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series |
title_fullStr | Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series |
title_full_unstemmed | Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series |
title_short | Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series |
title_sort | safety and efficacy of two trabecular micro-bypass stents as the sole procedure in japanese patients with medically uncontrolled primary open-angle glaucoma: a pilot case series |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318622/ https://www.ncbi.nlm.nih.gov/pubmed/28265466 http://dx.doi.org/10.1155/2017/9605461 |
work_keys_str_mv | AT shibadaisuke safetyandefficacyoftwotrabecularmicrobypassstentsasthesoleprocedureinjapanesepatientswithmedicallyuncontrolledprimaryopenangleglaucomaapilotcaseseries AT hosodashingo safetyandefficacyoftwotrabecularmicrobypassstentsasthesoleprocedureinjapanesepatientswithmedicallyuncontrolledprimaryopenangleglaucomaapilotcaseseries AT yaguchisaori safetyandefficacyoftwotrabecularmicrobypassstentsasthesoleprocedureinjapanesepatientswithmedicallyuncontrolledprimaryopenangleglaucomaapilotcaseseries AT ozekinaoki safetyandefficacyoftwotrabecularmicrobypassstentsasthesoleprocedureinjapanesepatientswithmedicallyuncontrolledprimaryopenangleglaucomaapilotcaseseries AT yukikenya safetyandefficacyoftwotrabecularmicrobypassstentsasthesoleprocedureinjapanesepatientswithmedicallyuncontrolledprimaryopenangleglaucomaapilotcaseseries AT tsubotakazuo safetyandefficacyoftwotrabecularmicrobypassstentsasthesoleprocedureinjapanesepatientswithmedicallyuncontrolledprimaryopenangleglaucomaapilotcaseseries |